SMC Corporation of America
Elite Part Number Search
Search Results "VXA2120A-02-1-B"

When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .

How to Order Internal pilot operated relieving type regulator AR 25 4 BG 02 Semi-standard Nil Flow direction: Right to left None (Standard) Regulator R Body size Port size Accessory 4 6 8 9 1 2 1 Symbol 1 Description Applicable model 02 03 04 06 10 12 14 20 1 4 Nil 2 1 8 3 B With bracket AR4 5 to 6 5 AR 25 AR 35 2 1 2 3 4 Gauge G46-10-02 G46-2-02 G Regulating pressure range 1 G46-P10-02-X30

How to Order Applicable Valves B C6 SQ 1 3 5 1 Y 1 Series SQ1000 C H G B A D F E A A A A B A B 2.PUSH 2.PUSH 1.TURN 1.TURN D Coil voltage Type of actuation A 5 24VDC 2 position single 2 position double (latching/double solenoid) 3 position closed center 3 position exhaust center 3 position pressure center Dual 3 port valve N.C. + N.C. Dual 3 port valve N.O. + N.O.

Panel adapter B ZS-22-02 Specifications PF2W300/301 PF2W330/331 Model Flow rate measurement range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Set flow rate range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Minimum set unit Note 1) 0.05 l/min 0.1 l/min 0.5 l/min 1 l/min Accumulated pulse flow rate exchange 0.05 l/pulse 0.1 l/pulse

A 1-B 1-C 2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B CE2 6 1/8, 1/4 1.5 500 0 1,000 2,000 3,000 ML2B Max. speed Vmax (mm/s) 6 1/4, 3/8 3 1000 Graph 3:25 ML1C 10 1/4, 3/8 20 (1/4) 4.5 1500 20 10 1/4, 3/8 REA Composed effective area So (mm2) Composed effective

"#$ %&' % & ' ( ) * + % & ' ( ) * + Series VQD1000 Dimensions/Base Mounted Plug lead manifold unit (VV4QD15-) Lead wire length 300 mm (P,R port) For latching Indicator light B C A B C A B C A B C A B C A 2 x 4.5 (Mounting hole) (59.7/latching type) 57.5 52.5 3(R) 51 3(R) 16 9 32 1(P) 17 1(P) 10 10 P = 11 4 36.5 L1 L2 4 41.5 45 C4: 4 One-touch fitting M plug connector (M) Stations D side

When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .

Fail Action Fail to Close, Fail to Open 5 Valve Travel 85.2 % 5 Positioner Information 5 Dead Angle (a0) 0.0 % [0..99%] 6 Temperature 24.7 C 6 Units 6 Performance Level A(1)-Aggressive, b(1)-fast, C(1)-Optimum, d(1)-Stable, E-Max. stability, (1) = Capac.

Construction/Parts/Dimensions AN05/10/20 AN15/30/40 No hexagonal part in AN05 and AN10 B Dimensions (mm) B Port size R, NPT A B D Model Sound absorbing material (Resin sintered body) AN05-M5 AN10-01 AN15-02 AN20-02 AN30-03 AN40-04 6.5 15 M5 x 0.8 Body (Resin) A 23 1/8 11 A 32 1/4 14 16 Hexagonal flats D 14 45 1/4 16.5 17 58.5 3/8 20 Port size 21 68 24 1/2 2

Thread type Type Rc NPT G Symbol Nil N F Accessory (2) Port size Symbol Nil H Description With set nut ARG40 Body size Port size Symbol 20 30 40 01 02 03 04 1/8 1/4 Accessory (1) 3/8 1/2 Symbol Nil B Description With bracket (With nuts) Mounting Angle of Pressure Gauge JIS Symbol G4 G3 G2 G1 Symbol ARG20 to 40 270 180 90 0 Mounting angle MPa IN OUT IN OUT IN OUT IN OUT Mounting angle view

Type 21P Single base/B mount Common SUP/Common EXH 3 to 12 stations Valve Rc 1 8 M5 x 0.8 Model Manifold type P(SUP), R(EXH) Valve stations A, B port location 1(P), 3(R) port 4(A), 2(B) port Port size Valve (1) effective area (mm2) (Cv factor) 1 4: 0.48, 4 3: 0.85 VZ1120 Socket: 26 pins MIL, with strain relief (Conforming to MIL-C-83503) Applicable flat ribbon cable connector Internal wiring

Unit type Compliant sensor 1 2 N P B 1 connector, 2-input type NPN output Replaceable fuse (EX9-FU10) 1 connector, 1 input type PNP output 2-wire type Note) B (2-wire type) is available with 1 connector, 2-input type only.

) Exhaust (OUTEXH) Model IN, OUT EXH C(dm3/s-bar) b Cv C(dm3/s-bar) b Cv VHS20 1/8 1/8 4.0 0.41 1.1 3.7 0.42 1.1 1/4 5.8 0.31 1.4 3.8 0.42 1.1 6 VHS30 1/4 1/4 8.8 0.44 2.4 8.0 0.46 2.3 3/8 14.1 0.28 3.5 7.8 0.46 2.2 1/4 9.5 0.49 2.8 13.3 0.47 3.6 VHS40 3/8 17.2 0.47 4.8 13.6 0.47 3.7 3/8 1/2 26.7 0.29 6.3 13.4 0.43 3.7 -6- 4.

Dimensions (mm) Weight (g) Effective area (mm2) Recommended flow (m3/min (ANR)) Port size R Model A B C 1 8 1 4 3 8 1 2 3 4 1 1 1 14 64 22 18 ANA1-01 ANA1-02 ANA1-03 ANA1-04 ANA1-06 ANA1-10 ANA1-12 ANA1-14 ANA1-20 4 37 16 10 15 35 60 90 160 280 450 610 0.8 or less 1.2 or less 2.7 or less 4.5 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 84 25 21 98 30 24 111 46

1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: Pneumatic fluid power General rules relating to systems JIS B 8361: Hydraulic fluid power General rules relating to systems JIS B 9960-1: Safety of machinery Electrical equipment of machines (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety, etc *2) Labor Safety

) Model A B P PF2M701/702/705/710/725/750-01(-L) 66 14 2.8 depth 8.4 PF2M701/702/705/710/725/750-N1(-L) 68 14 2.8 depth 8.4 PF2M701/702/705/710/725/750-F1(-L) 70 14 2.8 depth 8.4 PF2M711/721-02(-L) 70 17 2.8 depth 6.2 PF2M711/721-N2(-L) 70 17 2.8 depth 6.2 PF2M711/721-F2(-L) 78 21 2.8 depth 6.2 -101No.PF-OMW0007-E PF2M7#L-#1/2(-L) (mm) Model A C B P PF2M701/702/705/710/725/750L-01(-L) 84.4

(B contact). Contact output signal 3 WRN alarm selects N.O. (A contact) or N.C. (B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-28 Setting of contact output signal 1 to 3 No.

Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -37No.PS-OMY0007-A [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.