You do not need to specify "N" (i.e., without lead wire) for D-A3, D-A44, D-G39, and D-K39.
Do not use the product in a place where static electricity is a problem.
Warning 1 2 Sensor Monitor PF23 4 3 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 4 8 Switch output 1 Black Output for PF23 Main circuit Pin number Content Colour 3 7 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
OUT2 over current error Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. Zero clear was performed in non-atmospheric pressure. (Pressure outside of 14 kPa was supplied at factory default settings.) Perform zero clear at atmospheric pressure.
1000 1000 1000 1000 X Motorless 500 500 500 500 LAT 0 0 0 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14 16 0 4 8 12 16 20 24 0 10 20 30 40 50 60 LZ Work load [kg] Work load [kg] Work load [kg] Work load [kg] 2000 2000 2000 2000 LC3F2 Mey 1500 1500 1500 1500 L5 [mm] L5 [mm] L5 [mm] L5 [mm] m 1000 1000 1000 1000 Wall L5 Y 500 500 500 500 0 0 0 0 4 8 12 16 20 24 0 10 20 30 40 50 0 0 2 4 6 8 10 12 14
14.5 9 8.5 20.5 14 25 25 29.5 30 27 74.5 64.5 15 17.5 12 16 10.5 19.5 14 14.5 9 8.5 20.5 14 REC 32 32 33 33.5 30.5 78 68 15 19.5 12 18 10.5 21.5 14 16.5 9 8.5 22.5 16 40 40 37.5 38 35 82.5 72.5 20 24.5 17 23 15.5 26.5 19 21.5 14 13.5 27.5 21 CX 50 50 43 43.5 40.5 88 78 18 28.5 15 23.5 13.5 27 17 22 12 11.5 28 21.5 63 63 50.5 50.5 47.5 95 85 18 28.5 15 23.5 13.5 27 17 22 12 11.5 28 21.5 CY
Set value Set value or 3 4 or 3 Accumulated pulse Time ( ) U P Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 4 1 2 U P Flow DOWN DOWN 4 3 DOWN Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not disassemble or modify the main unit. Precautions on Use of Other Tubing Brands Caution 1.
Do not use in locations where static electric charges will be a problem. Please consult with SMC regarding use in this kind of environment. 2. Do not use in locations where spatter occurs. There is a danger of spatter causing a fire. 3. Do not use in environments where there is direct contact with liquids such as cutting oil, lubricating oil or coolant oil, etc.
Do not repair or patch the replaced tubing or fittings for reuse. 15-6-30
Do not use in a location having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. Do not use in locations where radiated heat will be received from nearby heat sources.
Do not disassemble the power clamp No special maintenance is necessary because the power clamp has a fully enclosed design to protect the clamp against welding spatter, and also the power clamp has a contamination resistant construction. Do not disassemble any parts other than replaceable parts, otherwise it may reduce the performance of the clamp cylinder. 3.
Insert the cover. 13 XL-OMO0001-A Revision history Limited warranty and Disclaimer SR 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2012 SMC Corporation All Rights Reserved 14 XL-OMO0001-A
Do not use these for pneumatic operations because they will lead to oil leaks.
(inch) Connection thread UNF NPT
Do not use a lubricator on the inlet side of the product, as the bleed mechanism can malfunction. Caution IRV 1. For emergency action in the event of setting failure or leakage from the relief port, refer to Troubleshooting in the Operation Manual of the product. VEX SRH Piping Warning SRP SRF 1.
Operating Range (mm) Bore size Switch types 25 32 20 D-A9, D-A9V D-F9, D-F9V D-F9W, D-F9WV 11 12.5 14 6.5 7 7 Values in this table include hysteresis and are to be used as a guide only. They do not guarantee an actual fixed range (expect approximately 30% dispersion).
Ambienr rempeErure 10-60"C(14'-140'F) . Proleclion slruclure IEC spec 1P67, WaleFPrcof(Jlscog2o) x fi 114ln lead wire is r6quned, L is pd at rhe end of model number. (Example) D-r7A1L o (.)
o 0.62 322 1.28 14 oaa {4) 250 u-24 0.50 .621 .621 0.25 0.93 0.38 1t-1E .251 .250 0.75 0.25 0.34 0.75 o.75 o.1a cts16 0.75 120 o.62 3.19 3.8:t 343 t06 {17-l _312 6t-21 0.50 .621 .621 0.38 1 . 1 2 0.38 5t-i E .25r .250 0.75 0.25 o.3a 3.97 o.8a o_aao.24 qi-14 o.75 1.30 0.62 334 1.25 125 t 2 5 t 1 k ) 375 \-24 o.aE .749 .749 o.11 r.32 0.50 .251 o.25 0.41 rt.4 1.06 r.06 0.25 sa-l6 0.46 r.62 0.78
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove. Refer to pages 16-14-3 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-111 to 16-1-13 for Precautions on every series.