Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.
Do not apply any impact when you load the cylinder in the locked position.
6mm Tube 08 8mm Tube 10 10mm Tube 01 Rc 18 02 Rc 14 Operating Temperature Range 5 ~ 60C / 40~140F N Canada, USA Other (PT) Lubrication Forbidden N O Z Z L E D I A M E T E R V A C U U M P O R T 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm 06 6mm Tube 08 8mm Tube 01 Rc 18 02 Rc 14 07 1/4 Tube 11 3/8 Tube T01 1/8NPT T02 1/4NPT S Y M B O L S T Y P E I N L E T P O R T B Box type D Body type 06 6mm Tube
Set pressure range [MPa] 0.1 to 1.7 Ambient and fluid temperature [C] 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Model AR20-B AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B Port size 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 r BG AR B B X430 30 03 BG q 30 AR
Flat washer AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 AS-31B AS-32B AS-33B AS-34B AS-35B AS-36B AS-37B AS-38B AS-41B AS-42B AS-43B AS-44B AS-45B AS-46B AS-47B AS-48B AS1002F-01 AS1002F-03 AS1002F-07 AS2002F-03 AS2002F-07 AS2052F-07 AS2052F-09 AS3002F-07 AS3002F-09 AS3002F
84 25 21 98 30 24 111 46 36 132 50 41 200 74 60 230 74 60 271 86 70 JIS Symbol 1 4 1 2 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Construction/Parts/Dimensions ANA1-01 to 06 Sound absorbing Case material (PFV ) End plate Hexagonal flats ANA1-06: PP How to
ASD Model Meter-out type Rod and applicable tubing O.D. 4 10 8 6 Meter-in type AS1000P-04-04 AS2000P-04-04 AS2000P-06-06 AS2500P-06-06 AS3000P-08-08 AS3000P-10-10 AS1010P-04-04 AS2010P-04-04 AS2010P-06-06 AS2510P-06-06 AS3010P-08-08 AS3010P-10-10 AS AS-FE KE
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
Do not introduce air from the outlet side as this can damage the damper. Caution 1.
Do not touch the leakage of fluid without care. If the fluid has high temperature or is chemical, the contact could result in burn and other injuries. 3) Disassembly Do not disassemble the pump. Caution 1) Quality of supplied air Mount the filter with filtration of approx. 0.01.
(Outlet flow rate:0L/min) Do not rotate the handle to a pressure If the inlet pressure fluctuation is large, the outlet pressure maybe exceeding the max. set pressure. over the setting range of governor, and that will result in an unexpected accident.
Dimensions q Do not use the air cylinder as an air-hydro cylinder. This will cause an oil leak. w Install without twisting the bellows. If the cylinder is installed with its bellows twisted, it could damage the bellows. Rubber bumper Disassembly/Replacement Caution q Do not replace the bushings or the cushion seals. The bushings and the cushion seals are press-fit.
If the tubing is inserted without holding the elbow, excessive force can be applied to the valve and fitting assembly, causing air leakage or damage, etc. 1) Nylon tubing within 0.1 mm 2) Soft nylon tubing within 0.1 mm 3) Polyurethane tubing within +0.15 mm, within 0.2 mm Do not use tubes which do not meet these outside diameter tolerances.
If the tubing is inserted without holding the elbow, excessive force can be applied to the valve and fitting assembly, causing air leakage or damage, etc. 1) Nylon tubing within 0.1 mm 2) Soft nylon tubing within 0.1 mm 3) Polyurethane tubing within +0.15 mm, within 0.2 mm Do not use tubes which do not meet these outside diameter tolerances.
Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
Table (3) Additional Mass [g] 1 50 100 150 200 250 300 10 20 31 4 25 44 9 32 61 13 40 99 14 50 99 22 63 148 24 80 207 35 100 Bore size (mm) Additional mass per 50 mm of stroke Switch magnet 20 4 Cylinder stroke (mm) Do not apply a lateral load over the allowable range to the rod end when it is mounted horizontally.
AL10/20 AL30/40/40-06 AL50/60 Body Zinc die-casted Aluminum die-casted q i Platinum silver Platinum silver Housing Aluminum die-casted Replacement Parts Part no. Material Description No.
Olill3.0iltx5(fl{Sl 5.0 18.8{ 7 { t + 010/.0M 7 q l + 010/ m l . +.0050 /..010 r.50 .630 +.AN/-.0n0 3.881.50 1.50 L40 |.06 il/A .90 0Eltll3.()ilx6.5(.lt(S) 6.5 22.59 7 5 1 *.oi 7. ooo .t 5l + 0t0/.1 -h9^q {0 L + 00150 / 010 1.50 3.56 .630 +.020/-.000 3.88 1.501.501.40r.06 t.ii N/A .90 33.6 lbs.
Example) AR30K-03BE-1NR-B w e V q Body size 20 25 30 40 50 60 Symbol Description V w With backflow function Nil Without backflow function K Note 1) With backflow function + V e Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 V r Port size + a Mounting Nil Without mounting option B Note 3) With bracket H With set nut (for panel mount) + Nil Without pressure
Model symbol (In-line filters) Element size 125mm 65 x 250mm Bore size 04 06 Rc 1/2 Rc 3/4 2.