Do not use in an atmosphere having corrosive ! Grommet gases, chemicals, sea water, water, water vapor, or where there is direct contact with any of these. Class B coil: AWG20 Outside insulator diameter of 2.5 mm 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or q impact. 4.
Do not use valves where there is direct contact with, or in atmospheres of, corrosive gases, chemicals, salt water, water or steam. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. Confirm the specifications for each series. 4. A protective cover should be used to shield valves from direct sunlight. 5.
Do not use in explosive atmospheres. 2. Do not use in locations subject to excessive vibration or impact. 3. Do not use in locations where radiated heat will be received from nearby heat sources. 0.4 to 0.6 1. Removing the product Shut off the fluid supply and release the fluid pressure in the system. Shut off the power supply. Remove the product. 2.
Do not attempt to rotate, as the connector does not turn.
Do not use this product in an enclosed space. This product utilizes a corona discharge phenomenon. Do not use the product in an enclosed space as ozone and nitrogen oxides exist in such places, even though in marginal quantities. Also, ozone condensation can increase if used in an enclosed space, which can affect the human body, so ventilation is necessary.
Transporting with casters 1) This product is heavy and should be moved by at least two people. 2) Do not grip the piping port on the right side or the handles of the panel. 3) When transporting using a forklift, be sure not to let it hit the casters or adjusters, and drive the fork all the way through until it comes out the other side. 4) Do not get across steps with casters.
Do not apply a load in excess of the specification limits. 1. Do not allow the table to hit the end of stroke. LEJ LEJ Select a suitable actuator by work load and allowable moment.
(Current output) Load Blue DC(-) NOTE : The unconnected terminals are used in SMC, so please do not connect them. Use the specified voltage. Use within the specified operating pressure. Do not drop, hit or apply shock to the Pressure Sensor. Do not pull the lead wire forcefully, not lift the product by pulling the lead wire. Wire correctly. Do not perform wiring while the power is on.
(If you do not cycle the power, it does not register the data in the driver.) Note2) Selected Items Write: Writes the parameter values of the corresponding frame to the driver. Single Axis Write: Writes all of the parameters to the driver. Note3) Do not change For manufacturer setting parameters.
Do not use in environments or locations where the equipment is exposed to cleaning solvent, etc. and oil film on rod may be washed away. Seals may break due to insufficient lubrication, causing air leakage. 13 - 4. Do not store cylinders in humid places. Humid environment should be avoided when storing cylinders.
If the piston speed increases excessively, internal parts, guides, etc. may be damaged. 5) Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals etc. will result in leakage or malfunction. 6) Do not dent or scratch the mounting surface of the body and the plate.
IEC 60204-1: Safety of machinery -Electrical equipment of Do not use in an explosive atmosphere. Do not expose to direct sunlight. Use a suitable protective cover. Do not install in a location subject to vibration or impact. Check the Maintenance of pneumatic systems should be performed only by qualified personnel.
Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. Refer to the construction drawings regarding the air chuck materials. 2. Do not use in direct sunlight. 3. Do not operate in a location subject to vibration or impact. 4. Do not mount the product in locations where it is exposed to radiant heat. 5.
Do not operate with the magnetic coupling out of position. If the magnetic coupling is out of position, push the external slider (or the piston slider by using air pressure) back to the proper position at the stroke end. (When pushing the external slider, do not push it with bare hands.) 4. Do not apply lubricant, as this is a non-lube product.
Do not use compressed air which contains chemicals, organic solvents or corrosive gases. Do not use compressed air containing chemicals, organic solvents, salt or corrosive gases, as this can cause damage and reduced performance, etc. 3. Operating pressure range The operating pressure range is determined by the equipment being used.
Do not use with fluids other than compressed air. Cleaning equipment is designed exclusively for use with compressed air. Contact SMC in advance if a fluid other than compressed air is to be used. 2. Do not use compressed air which contains chemicals, organic solvents or corrosive gases.
Do not use in these conditions. (Refer to specifications.) Consult SMC if you use a fluid other than compressed air. 2.
Do not insert metal wires or other foreign objects into the pressure measurement port.
Do not apply fluid under leaking conditions.
Torque Thread size Bore 16 to 40 50, 63 M3 0.6 M4 1.4 End plate Note 1) Do not move the end plate upward inadvertently.