(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E. Pollution degree For use in Pollution Degree 3 Environment (UL508) Standard CE, UL(CSA), RoHS Weight 170 g 175 g 1: All unused connectors must have a seal cap fitted. 2: The UL agreement temperature is 0 to 50 oC.
Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.
VDC Mega) between external terminal and case Insulation resistance 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration in each X, Y, Z direction for 2 hrs., whichever is smaller.
Pressure 0.5 MPa Load rate: 50% Stroke 60 mm Series MB/CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series MB/CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ7140-02 Cylinder is in extending.
1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Features 6
Buffer Specifications Model MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 6 8 12 16 20 25 Bore size (mm) Horizontal mounting 2-20 in/s (50~500 mm/s) 2-12 in/s (50~300 mm/s) Piston speed Buffer stroke (mm) 5 10 At 0mm stroke At max. stroke 0.67 1.12 2.25 2.92 3.82 4.72 Buffer stroke load (lbf) 1.35 1.80 2.92 3.82 5.62 6.52 Note) Refer to P. 14 for cautions on buffer.
moment 70 MXW25 70 100 50 30 40 N m 50 MXW20 Pitch moment Yaw moment Roll moment 25 30 40 MXW20 Model 20 Moment N m Moment N m Mp/Mep My/Mey Mr 15 MXW16 20 MXW16 12 5 5 3 MXW 8 10 15 7 10 MXW12 MXW12 10 10 6 MXW12 4 5 7 5 4 3 20 20 12 MXW16 MXW8 MXW8 3 2.5 40 40 25 MXW20 2 110 110 65 2 1.5 MXW25 50 100 200 300 500 700 50 100 200 300 500 Piston speed mm/s Piston speed mm/s (Graph3) (Graph2
Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1
SYJ300/500/700 Preferred Option Summary Option Light and surge voltage suppressor Series Type of actuation Voltages Electrical entry Manual override Manifolds L type plug connector SYJ300 Type 42 N.C. N.O.
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
MRQ Mass Rotating angle Size Basic mass (g) Flange (g) Add'l stroke mass (g/mm) 80 to 100 1400 4 500 32 170 to 190 1500 80 to 100 2100 40 5 500 170 to 190 2300 Calculation: (Example) MRQBS32-50CA Basic mass 1400 g 4 x 50 = 200 g Stroke additional mass Total 1600 g For the mass of auto switch alone, refer to pages 767 to 809.
condensation and freezing) 14 to 140 (No condensation and freezing) 35 to 85 (No condensation and freezing) Serial communication Memory LED indicator Lock control Cable length (m) Cooling system Operating temperature range (F) Operating humidity range (%) Storage temperature range (F) Storage humidity range (%) Insulation resistance (M) Between the housing (radiation fin) and SG terminal 50 (500
For details, refer to the optional accessory (page 11). 6 HEF Series Cooling Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 600 600 500 500 Cooling capacity [W] Cooling capacity [W] Ambient temperature 25C 400 400 Ambient temperature 25C 300 300 200 200 Ambient temperature 35C Ambient temperature
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal HRSH 090 HRSH To the thermo-chiller Users equipment side HRSE 7 24 VDC 6 24 VDC output (500 mA MAX) 5 HRZ 15 14 HRZD 24 VCOM output 13 24 VCOM HRW Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k HECR 11 Run/stop
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (No inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Contact input signal 2 Circuit diagram 4 1 k 11 Run/stop signal input Contact input signal
mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting 12 4.7 k Circuit diagram Contact input signal 2 4 1 k 11 Run/stop signal input Contact input
76 0.7 0.1 0 500 300 1000 1500 81 75 66 51 0.3 REB Cylinder stroke (mm) G 60 55 49 37 0.5 REC The above curve in the graph refers to P = 0.5 MPa of supply pressure.
12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 (Both sides) 1300 25 12-CY3B25 Non-lube 32 12-CY3B32 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B40 40 Note 1) Stroke exceeding the standard stroke but below the maximum possible stroke is available for special order upon request.
76 0.7 0.1 0 500 300 1000 1500 81 75 66 51 0.3 REB Cylinder stroke (mm) G 60 55 49 37 0.5 REC The above curve in the graph refers to P = 0.5 MPa of supply pressure.
26 or less 0.28 0.52 0.11 2.4 0.56 0.17 2.5 1 4 VP4 3 position VZS3450 500 26 or less 0.28 0.49 0.11 2.4 0.56 0.17 2.5 1 4 VZS VZS3550 500 26 or less 0.28 0.53 0.16 2.4 0.60 0.12 2.8 1 4 VFS Double check VZS3650 420 32 or less 0.43 1.2 1.1 1 4 VS4 Note 1) Min. operating cycle is based on JIS B 8375 (One time per 30 days).