M3E = 1/3 x FE x Y = 1/3 x 188.7 x 25/1000 = 1.6 [Nm] 3B = M3E/M3max = 1.6/17.1 = 0.09 M3 Refer to [3] Calculation for Overall Center of Gravity in the Y-axis on front matter 7.
PAX PB Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 17-5-53 12 Series LVD Special Tools How to order fitting jigs LQ G
1 !1 !2 !2 !3 !3 !4 !4 !5 !5 M5 port M5 port y y u u !7 !7 q w e r t q w e r t o o !0 !0 !1 !1 i i !4 !4 !2 !2 !3 !3 !6 !6 Component Parts Description Material Description Material No.
Port size Body size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF 1 2 0 M5 06 AS 1F S G Body size 1 S Body size 2/3/4 AS 2 2 0 1F S G 01 06 With indicator Body size Made to Order Refer to page 698 for details. 2 1/8, 1/4 3 3/8 4 1/2 Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Control type Note) 0 Meter-out 1 Meter-in Note) Face seal type is used for the G thread
)*3 R: Right LEPY LEPS *1 The standard cable should be used on fixed parts.
B C Type of actuation Type of actuation 2 position double 2 position double 3 position closed center 3 position exhaust center 3 position pressure center Symbol 1 2 3 4 5 Function Function Standard type (1W) High pressure type (1.5W) External pilot Low power consumption type (0.5W) Symbol Nil H R Y 1 Stations U side D side 2 3 Note 1) When specifying two or more, list them in alphabetical
1 i q !4 r e !0 !1 q i !2 o !3 y Meter-in type Component Parts No.
k 11 Run/stop signal input Contact input signal 1 4.7 k 3 1 k Internal circuit 10 Alarm status signal output Contact output signal 3 2 9 Remote status signal output Contact output signal 2 1 8 Operation status signal output Contact output signal 1 0 * The pin numbers and output signals can be set by user.
A) 2 (A) 54 46 1 (P) 3 (R) 1 (P) 3 (R) 4 (B) 4 (B) 4-Rc 3/4 4-Rc 1/4, 3/8, 1/2 5-8-14 9 Hand Valve Series VH Precautions Be sure to read before handling.
Qty. u Kit no. r (Nominal) 1 1 3 3 5 Element AMF800 AMF801 AMF900 AMF901 AMF1000 AL-61S AL-60S AL-63S AL-62S AL-31S AL-61S AL-60S AL-63S AL-62S AL-31S 1 1 3 3 5 1 3 5 1 1 1 1 1 1 1 3 3 5 OD112XID90XT3 e KA00061 1A-G35 63271 63148 OD112XID90XT3 Drain N-3 OD112XID90XT3 251 252 Industrial Filters 1 Indication of replacement of elements, inspection items Actuators Modular F.R.L.
Qty. u Kit no. r (Nominal) 1 1 3 3 5 Element AMF800 AMF801 AMF900 AMF901 AMF1000 AL-61S AL-60S AL-63S AL-62S AL-31S AL-61S AL-60S AL-63S AL-62S AL-31S 1 1 3 3 5 1 3 5 1 1 1 1 1 1 1 3 3 5 OD112XID90XT3 e KA00061 1A-G35 63271 63148 OD112XID90XT3 Drain N-3 OD112XID90XT3 251 252 Industrial Filters 1 Indication of replacement of elements, inspection items Actuators Modular F.R.L.
Type 2 3 Elbow Universal Applicable tube outside diameter Metric size Inch size 3.2 4 6 8 10 01 03 05 07 09 11 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 23 04 06 08 10 Control system 0 1 Meter-out Meter-in Use a 1/8" tube.
Model: 3000 (SV3000), Valve Manifold Stations: 3
Model: 1000 (SV1000), Valve Manifold Stations: 3
Model: 4000 (SV4000), Valve Manifold Stations: 3
Frequency (Hz), Remote controller IZS40 IZS41 IZS42 Remote controller Remote controller 0 1 2 3 4 5 6 7 8 9 1 3 1 0.1 5 3 0.5 8 5 1 10 10 3 15 15 5 20 20 10 30 30 15 DC+ DC+ 20 DC DC 30 Set when remote controller is used. 429 IZS40/41/42 Series Wiring Circuit/IZS41, 42 NPN specification Shield Ionizer (IZS41, 42) Green F.G. Ground with a ground resistance of 100 or less.