Stations: 21 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 9 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 13 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 10 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 2 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 3 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 4 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 5 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 6 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 12 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 3 Stations, Manifold Type: D-sub Connector 25 Pin 3.0m, Option: -, One-touch Fitting: -
Stations: 4 Stations, Manifold Type: D-sub Connector 25 Pin 5.0m, Option: -, One-touch Fitting: -
Stations: 8 Stations, Manifold Type: D-sub Connector 25 Pin 5.0m, Option: -, One-touch Fitting: -
Stations: 11 Stations, Manifold Type: D-sub Connector 25 Pin 3.0m, Option: -, One-touch Fitting: -
Stations: 5 Stations, Manifold Type: D-sub Connector 25 Pin w/o Cable, Option: -, One-touch Fitting: -
Material Case Note 1 Stainless steel 316 Electrolytic polishing (Interior/Exterior) V-clamp 2 Stainless steel 304 Holder 1 3 Polyester Holder 2 4 Filter medium 5 Element PTFE Seal 6 FKM V-seal 7 300 SFA100/200/300 Series Clean Gas Filter: Cartridge Type/Disc Type Flow Rate Characteristics Fluid: Compressed air Inlet temperature: 20C Dimensions SFA100/101, SFA200/201, SFA300/301 SFA10 Inlet
Note2) The value at temperature of 20C and O.D. variable rate 10% max.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232
Note 5) As for other commercial items, there are some cases it is not able to connect due to tolerance of dimensions. 2R Fixed side At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%.
Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube. 3.The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure on the right. Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed. Fixed end 1232