H 4 S y m b o l Initial power/ Power 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 consumption (W) Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
H 4 S y m b o l Initial power/ Power consumption (W) 100 VAC 600/150 800/220 1200/350 200 VAC 2400/150 3200/220 4800/350 Heater assembly number XLA25-60S-2 XLA25-60S-2 XLA25-60S-2 No. of heater assemblies 2 pcs. 3 pcs. 4 pcs.
4 ZCU Standard (Without options) M3 x 0.35 x 70 4 [For ZSE4 spec.] [For ZSE4 spec.] With function plate M3 x 0.35 x 75 4 Standard (Without options) M3 x 0.35 x 19 6 AMJ !5 With function plate M3 x 0.35 x 24 6 Components Vacuum switch/Filter unit Misc. 13-3-49
H4 Initial power / 100 VAC 200/40 200/50 400/100 600/150 Power Symbol 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.
Applicable dryer Capacity Model Inlet voltage Outlet voltage A B C D E F Weight (kg) 200, 220 230, 240 VAC (50 Hz) 200 to 260 VAC (60 Hz) 100 VAC (50 Hz) 100 to 110 VAC (60 Hz) Single phase Single turn IDF-TR500-2 IDF1E-10 to 8E-10 IDU3E-10, 4E-10 500 VA 118 140 150 70 112 142 6 IDF-TR500-3, 4 C VOLUTAGE SELECTOR FUSE B OUT PUT IN PUT E D 4-F A Input cord 2 m Transformer part no.
When the Hysteresis exceeds 10m use the Air-Catch Sensor as a confirmation of position of work piece. : Stable adjustment range Detection side nozzle: 1.0 Detection side piping: 6 X 4 tubing Detection side nozzle: 2.0 Detection side piping: 6 X 4 tubing Detection side nozzle: 1.5 Detection side piping: 6 X 4 tubing 70 70 70 60 60 60 Supply pressure Supply pressure Detection not possible 50
2.3 45 1/4, 3/8 70 150.5 36 68 70 70 54 70 55.5 27.5 7 65.5 85 12.5 8.5 75 2.3 50 1/4, 3/8, 1/2 23 Regulator with Built-in Pressure Gauge with Back Flow Mechanism Series ARG20K/30K/40K How to Order ARG 20 K 01 G1 Option Body size Description 0.02 to 0.2 MPa setting Non-relieving type Name plate and pressure gauge in imperial units (PSI) Symbol Nil 1 N Z Symbol 20 30 40 Port size 1/8 3/8
Overhang direction:L3[mm] 250 250 600mm stroke L3 m 200 200 500mm or less 150 150 600mm stroke or less 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 300 300 250 250 Overhang direction:L4[mm] L4 m Overhang direction:L4[mm] 600mm stroke 200 200 600mm stroke or less 500mm stroke or less 150 150 100 100 50 50 0 0 0 1 2 3 4 5 0 1 2 3 4 5 Workload[kg] Workload[kg] 500 500
S 6 50, 100, 150, 200 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com "n" pcs. n 8 50, 100, 150, 200, 250, 300 12 50, 100, 150, 200, 250, 300, 350, 400 Auto switch type Nil Without auto switch Adjuster option Nil Rubber stopper B Shock absorber Metal stopper One
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 11 For Water Digital Flow Switch Series PF2W Refer to www.smcworld.com for details of products compatible with overseas standards.
VF (4(A), 2(B) port) 2n-Rc 1/8 VFR (Pitch) (Mounting hole) VP4 6-Rc 1/4 (1(P), 3/5(R) port) VZS VFS VS4 VQ7 EVS (Light/Surge voltage suppressor) Triangle mark VFN (Station n)(Station 1) Connector polarity indicator Applicable connector: 26 pins MIL (Conforming to MIL-C-83503) Built-in One-touch fittings (mm) Stations 4 5 108.5 109 12 272.5 252.5 L1 L2 3 88 68 129 109 6 149.5 129.5 7 170 150
4-18-4.) 15 or less Max. operating frequency (Hz) 10 Non-locking push type, push-turn locking slotted type, push-turn locking lever type Manual override (Manual operation) Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Pilot exhaust method Body ported Lubrication Mounting orientation Shock/Vibration resistance (m/s2) Note 2) Not required Unrestricted 150
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 11 For Water Digital Flow Switch Series PF2W Refer to www.poweraire.com for details of products compatible with overseas standards.
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 15mm 10mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 20mm 15mm 10mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt
100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.
1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)
Collision speed (m/s) 0.05 to 5 Max. operating frequency (cycle/min) Max. allowable thrust (N) 70 70 45 45 25 10 422 422 814 814 1961 2942 Allowable temperature range (C) 10 to 80 Effective atmosphere Non-water soluble cutting oil 4.22 4.22 8.73 11.57 22.16 8.73 Extended Spring force (N) 6.18 6.86 14.61 17.65 38.05 14.12 Retracted 26 26 70 150 365 70 Basic type With cap Weight (g) 28 28 75
1/4, 3/8 VCW41 30 50 93.5 41 13.5 17 36 25 23 M5 26 66.5 48 64.5 62 62 50.5 103 64.5 70 1/2 35 60 101 41 17.5 17 36 30 28.2 M5 26 70 48 68 62 65.5 50.5 103 68 70 3/4 4.5-6 Direct Operated 2Port for Water Series VCW Dimensions (N.O.)
60 50 40 30 20 10 Measurable within this range PF3W 0 0 10 20 30 40 50 60 70 80 90 Aqueous solution temperature [oC] Wetted Parts Construction o !
Note 1) Note 2) Maximum available stroke (mm) Bore size (mm) 20 25 32 40 Standard stroke (mm) Model Long stroke (mm) 1 pc. 201 to 350 301 to 400 301 to 450 301 to 800 25, 50, 75, 100, 125, 150, 200 D-C7, C8 D-B5, B6 D-H7 D-G5N 10mm 15mm 1500 25, 50, 75, 100, 125, 150, 200, 250, 300 15mm 10mm 20mm 20mm D-B59W D-H7LF Note 1) Intermediate strokes other than the above are produced upon receipt