valve control (timer setting with PLC is unnecessary) Allows sharing of switch/valve power supply, and single line for suction signal (valve wiring is unnecessary) Timer can be easily adjusted without programming Models Standard supply pressure Nozzle diameter (mm) Diffuser construction Air consumption l/min (ANR) Max. suction flow rate l/min (ANR) Model S M H ZMA05H 0.5 12 18 ZMA07H 0.7 24 23
This is a legacy product, and replaced byZSE20BF-T-01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .24738 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20B-V-01-W-X500, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .30602 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20B-Y-01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .26054 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20B-Y-01-W-X505, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .21830 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20B-T-01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .25015 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
This is a legacy product, and replaced byZSE20B-Y-01-W-X503, VACUUM SWITCH, H/PRECISION, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .30777 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift
This is a legacy product, and replaced byISE20B-T-M-01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .30802 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byZSE20B-R-01-W, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .28955 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay accuracyIndicator
This is a legacy product, and replaced byZSE20B-X-01-W-X505, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .17196 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
This is a legacy product, and replaced byISE20B-T-01-W, SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, CA, ISE40/50/60 1/8 PT VERSION, .25994 lb, ModelRated pressure rangeDisplay/Set pressure rangeWithstand pressureDisplay/Minimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputAuto-shift inputDisplayDisplay
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 23 (ø3.2)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 23 (ø3.2), Seal: S (w/Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 23 (ø3.2), Seal: S (w/Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 23 (ø3.2), Seal: S (w/Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: R, Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 23 (Ø3.2), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Thread Type: R, Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 23 (Ø3.2), Seal Method: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread Type: N (NPT), Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 23 (Ø3.2), Seal Method: S (with Sealant)
Existing SY3000/5000/7000/9000 series part numbers: SYS□□20, SY□□40, and SY□□45
Plug-in type SY3000/5000/7000 series part numbers: SYS□□00, SY□□30, SY□□01, and SY□□31
The part numbers of the gasket assemblies for use between the existing SY3000/5000/7000/9000 series valves and manifold are as follows.
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: RZ (R + Z)