AMX-OMY0038-A PRODUCT NAME Activated Carbon Filter MODEL / Series / Product Number AMK20-(F, N)01 ~ (F, N)02(B)(-2, 6, C, R, Z)-D AMK30-(F, N)02 ~ (F, N)03(B)(-2, 6, R, Z)-D AMK40-(F, N)02 ~ (F, N)04(B)(-2, 6, R, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5. Construction / Options / Replacement parts 10 6.
Moreover, leakage current flow to the load will be n times larger when n auto switches are connected in parallel. 7. Do not use a load that generates surge voltage.
ID L P IDG K 4 x 13 IDK Dimensions AMG (mm) A B C D E F G K L M N P Q Port size Model AFF IDFA22E IDFA37E R 1 775 600 290 623 134 405 698 93 13 25 85 340 R 11/2 855 680 AM AMD IDFA55E, IDFA75E AMH A R B AME AMF Q E ZFC D SF G SFD F LLB C AD GD M N L P K 4 x 13 Dimensions (mm) A B C D E F G K L M N P Q R Model Port size IDFA55E IDFA75E 800 (868) R 2 470 855 (128) (273) (110) 13 500 75 700
One-touch fitting KQ2L13-03AS (IDFB60) KQ2H13-03AS (IDFB70, 80, 90) N H M O L K 4 x 13 IDFB60-11: Power cable with plug [Length: 110 inch (2.8 m)] Power cable outlet ( Electric wire diameter: IDFB60/70: 0.35 to 0.43 in (9 to 11) ) IDFB80/90: 0.71 to 0.91 in (18 to 23) [inch (mm)] Model Port size A B C D E F G H J K L M N O IDFB60 1 12.1 (307) 29.3 (745) 23.8 (605) 6.3 (161) 15.9 (405)
(Thread symbol N: 3/8 inch) (820) [200 VAC specification] Terminal block K L H M N J 4-13 P [200 VAC specification] Power cord outlet (17) [100 VAC specification] Power cord (mm) A B C D E F G H J K L M N P Q Port size Model IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E 69 101 270 32 21 330 413 38 150 3/8 226 410 240 15 51 232 138 24 327 125 67 304 33 73 31 36 154 21 330 473 1/2 13 453 283
BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Excess at no communicatio n monitoring time. Broken wire o r coming off 60 sec. 60 sec. AL19 Communication error is generated.
Connector mounting position SYJ300 M1.7 0.12N.m SY3000-37-81A-2-N Single1 to 4stations SYJ500 M2.5 0.45N.m SY3000-37-81A-2-5 Double/3 position : 1 to 4 stations SS5YJ3-21,32SA SY3000-37-81A-1-N Single5 to 8 stations SYJ700 M3 0.8N.m SY3000-37-81A-1-4 Double/3 position : 5 to 8 stations SS5YJ5-20,40,42,43SA SY3000-37-81A-2-N Single1 to 8stations SY3000-37-81A-2-5 Double/3 position : 1 to 8
k d r a i n p o r t Rotates 360.
Vacuum pressure Theoretical lifting force Horizontal lifting force [N]Safety factor 1/4 [kPa] [N] 1 cup gripping -50 40.2 10.0 2 cups gripping -67 53.8 13.4 3 cups gripping -73 58.7 14.6 (Calculated by W = P X S, S = r2, r = 32 / 2. Refer to 3.3 How to calculate theoretical lifting force for the detail.)
Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
Single numerical data instructions (1 Stations occupied) [Remote IO] PLC memory PLC memory address Signal name address Signal name Rx Ry 00 OUT0 00 IN0 01 OUT1 01 IN1 02 OUT2 02 IN2 03 OUT3 03 IN3 04 OUT4 04 IN4 05 OUT5 05 IN5 06 06 07 07 08 BUSY 08 HOLD 09 SVRE 09 SVON 0A SETON 0A DRIVE 0B INP 0B RESET 0C AREA 0C SETUP 0D WAREA 0D JOG (-) 0E ESTOP 0E JOG (+) 0F ALARM 0F FLGTH 10 to 1A
Rc(PT)1 4 KBZ1-04 KBZ1-06 4 6 KBZ2-08 8 KBZ3-10 10 KBZ3-12 12 KBZ4-12 Rc(PT)3 8 16 Bulkhead female connector: KBE Female connector union: KBH T Connecting thread Tube O.D. Part No. Part No.
Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
N/A 1 OUT ALARM01 to 32 N/A Allows the selection either TEMP READY or AUTO PURGE signal.(Output for pin No. 8 of Chapter 8 8.1.6Communication specification Table 8-7 Contact Signal (page 8-16). See communication specification for details.
6 5 4 1 2 3 PE N L 7 L,N PE B A IDFA60-23-T IDFA70-23-T IDFA80-23-T IDFA90-23-T M3.5 8.5mm M4.0 9.5Mm [3.2.5 ] IDFA60/70/80/90 Series 12-3 IDX-OM-W094 T 12.5 IDFA60/70-23-T A B AC 230V50Hz CM OLR FM MC MC2 PRS PRS2 ILS THR C01 C11 TB CN GFCI EDV PE TDR BK WH IDFA80/90-23-T A B A B GR A B AC 230V50Hz SY BU BR YE OR G/Y / IDFA60/70/80/90 Series 12-4
Tubing Size Symbol Type Body Class Tubing outside diameter Metric size 4 04 6 06 8 08 10 10 1/8 03 3/16 05 1/4 07 3/8 11 1/2 13 3 J Inch size Table 2. AC Insert Pin. Holder Assy Model Number LQ-GPJ LQ-GPJ-N LQ-GPJS LQ-GPJS-N LQ-GJLQ-GJ-NLQ-GJSLQ-GJS-NLQ-GC Larger Diameter Tubing How To Order LQ GC Nil B None With bracket Type Table 1.
VQ 1M1 2 3 X2 17-2-89 Series VQ20/30 Dimensions Plug lead unit manifold (VV2Q22) Mounting hole 2-4.5 through A port C6: One-touch fitting for 6 C8: One-touch fitting for 8 DIN rail mounting 4-M3 x 0.5 Formulas L1 = (n 1) x 29 + 49 L2 = L1 10 L3 = L4 10.5 L5 = L1 11.2 Dotted line: DIN rail mounting (-D) 1 2 3 4 5 6 7 8 9 10 Dimensions n: Station (Max. 20) L n 11 12 13 14 15 16 17 18 19
Dimensions 10.5 103 10.5 Input/Output connector Power supply terminal block C N O 16.7 28.3 45 4.1 C N 1 C N 2 Input/Output connector (3.6) 5.1 49 113 50.5 4.5 Reduced-wiring Fieldbus System Static Electricity Elimination Equipment Alphabetical Index Length Measuring/ Counter 599 Series PCW 8 Point Input/Output Unit: HI/LO Setting Type Terminal Block: DIN Rail Mount Type Models Specifications