When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXD21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.)
When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXP21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes.
Low temperature operation Unless otherwise indicated in each valve's specifications, the valve can be used at temperatures as low as 20C, but take measures to prevent freezing or solidification of drainage and moisture, etc. Selection Warning 1. Air quality 1) Use clean air.
(coil temperature 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30msec occurs in the OFF response time.
station 14 ( ) ( + ) Yellow Black Socket side 14 25 2 ( ) ( + ) Brown 15 ( ) ( + ) Pink Black 3 ( ) ( + ) Red 3 stations { 16 ( ) ( + ) Blue White 1 13 Terminal No. 4 ( ) ( + ) Orange 4 stations { 47.04 17 ( ) ( + ) Violet D-sub connector cable ass'y (Option) Electric characteristics 5 ( ) ( + ) Yellow 5 stations { 18 ( ) ( + ) Gray Item Characteristic Conductor resistance /km, 20C
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" 1000 680 440 480 420 210 150 Flow rate l/min ANR (SCFM) INOUT (35.0) (23.8) (15.4) (16.8) (14.7) (7.35) (5.25) Effective area mmCv 15.2 10.4 6.7 7.3 6.4 3.2 2.3 (0.84) (0.58) (0.37) (0.41) (0.36) (0.18) (0.13) Note 1) Flow rate values are at a pressure of 0.5MPa (72 psi) and temperature of 20C (68F).
(mm)Thickness (mm)BundleStraight pipeColorApplicable fluidMax. operating Note 1)pressure (at 20C)Burst pressure (at 20C)Note 2)radius (mm)Max. operating temperature (Fixed use)MaterialBasic diameterTolerance10 m20 m50 m100 m50 Ft. (16 m)100 Ft. (33 m)2 mMetric sizes (Series TL)TL1008??10 x ?810?0.11?0.1--------??
(mm)Thickness (mm)BundleStraight pipeColorApplicable fluidMax. operating Note 1)pressure (at 20C)Burst pressure (at 20C)Note 2)radius (mm)Max. operating temperature (Fixed use)MaterialBasic diameterTolerance10 m20 m50 m100 m50 Ft. (16 m)100 Ft. (33 m)2 mInch sizes (Series TIL)TIL053/16andquot;3/16andquot; x 1/8andquot;4.75?0.10.8?0.08?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
1.5% F.S. or less (0.7 MPa, at 20C)?1.0% F.S. or less (0.7 MPa, at 20C), ?3.0% of F.S. or less in case of analog output?1.5% F.S. or less (0.1 to 1.5 MPa, based on 0.7 MPa)?
20 to 902.0 (at 20C)2.3 (at 20C)?0.10.45/0.65 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.76/7Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?