Magnet: D (Built-in), Mounting: C (Single Clevis), Bore Size: 40mm, Piping: Screw-in, Stroke: 100mm, Cylinder Rod Motion: Energized Extend, Rod Boot: None, Function: 2 (2 Position Double), Valve Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector
Bore Size: 32mm, Port Type: Rc (PT), Stroke: 100mm, Lock Position: R (Front Lock), Manual Override: N (Non-locking Type), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 25mm, Port Type: Rc (PT), Stroke: 100mm, Lock Position: R (Front Lock), Manual Override: L (Locking), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 16mm, Stroke: 100mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m Lead Wire)
Bore Size: 12mm, Stroke: 100mm, Adjuster: w/o Adjuster, Function: Standard, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m Lead Wire)
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 20mm, Stroke: 100mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket: C (Auto Switch Mounting Bracket)
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread Type: NPT, Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Retraction Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread Type: NPT, Stroke: 100mm, Body Option: Rod End Female Threads, Standard, Locking Direction: Retraction Locking, By-Pass Piping: None (Emergency Stop), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: Rc, Auto Switches: A93, Lead
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: A93,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, End Locking: [Included] Presence, Cushion: Rubber Bumper on Both Ends, Port thread type: NPT, Auto Switches: A93,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,