AS500/600 AS420 AS800/900 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Number of needle rotations Number of needle rotations Number of needle rotations 654 AS Series Speed Controller: Standard Type Large Flow In-line Type Construction: AS420/500/600 Construction: AS800/900 AS-F TMH ASD AS AS

Eccentric distance Stroke Operating pressure: 0.5 MPa 1000.0 Plate allowable lateral load (N) 100.0 100 Load weight (kg) 63 63 50 10.0 50 40 32 40 1.0 32 10 0.1 10 100 1000 Maximum piston speed (mm/s) 0 10 20 30 40 50 60 70 80 90 100 110 120 Stroke + Eccentric distance (mm) Relationship between Number of Needle Rotations and Piston Speed 32, 40 50, 63 800 800 32 32 50 700 700 600 600 63 Piston

After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit.

Rated voltage 1 2 3 4 5 6 7 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC 240 VAC (50/60 Hz) G: Lead wire length 300 mm H: Lead wire length 600 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) D: With connector T: Condait terminal E: Grommet terminal type has been discontinued.

Automation Electrical wiring G1/2, M12 connector M12 connector Contact resistance 25 m or less 50 m or less Allowable voltage fluctuation 10% Power consumption 0.45 W Min. applicable load 5 VDC, 1 mA (Load resistance) 5 VDC, 5 mA (Load resistance) Max. voltage 24 VDC Max. load current 50 mA Surge voltage suppressor Varistor Indicator LED Max. load inductance 0.5 H Insulation voltage 300 V 600

E S A U T OS W I T C H C A P A B L E A U T O S W I T C H 2 Pieces S 1 Piece See Accessories Without Auto Switch D With Auto Switch S T R O K E A D J U S T M E N T S T R O K E ( I N C H) M O U N T I N G With Adjustment Bolts (Std) B With Shock Absorber BC With Cap Type Shock Absorber BCS With One Cap Type Shock Absorber B Housing fixed P End plate fixed 100 1 200 2 300 3 400 4 500 5 600

Basic weight 500 st 2.44 (kg) (Foot style 32) Additional weight 0.09 (kg/50 st) Cylinder stroke 600 (st) 2.44 + 0.09 x (600 500)/50 = 2.62 kg Accessory Mounting nut Rod end nut 30 30 d d D D C C H H B B Material: Carbon steel Material: Carbon steel B Part no.

72) 67 (77) 76 (86) 85 (95) 94 (104) C(D)UW10-D 74 (99) 81 (111) 88 (118) 95 (125) 102 (132) 109 (139) 123 (153) 137 (167) 151 (181) C(D)UW16-D 132 (165) 145 (182) 158 (195) 171 (208) 184 (221) 197 (234) 223 (260) 250 (287) 275 (312) 301 (338) 327 (364) 353 (390) 379 (416) C(D)UW20-D 240 (294) 260 (319) 280 (339) 300 (359) 321 (380) 341 (400) 381 (440) 421 (480) 461 (520) 501 (560) 541 (600

Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.

After securing the cylinder, readjust the stroke with the adjustment bolt. 80 Load [N] 70 60 15 50 40 30 10 20 10 0 0 100 200 300 400 500 600 700 800 900 Distance between supports L [mm] Adjuster holder 6. There are limitations on the load mass and operating pressure in case the product is used in the vertical direction.

To obtain 600 L/min (ANR), the inlet supply flow rate needs to be as follows: 600 L + 720 L = 1320 L/min (ANR).
In addition, when the inlet pressure of the VBA20A is 0.5 MPa, the set pressure of the regulator must be 1.0 MPa in order to obtain an outlet pressure of 0.8 MPa at 600 L/min.

(page 72) 0x04C4 (1220) 0x04C5 (1221) 0x04C6 (1222) 0x04C7 (1223) Y S16 0x0258 4 R/W (600) WH1 (Setting of OUT1 window comparator hysteresis) Setting of OUT1 window comparator hysteresis.

Max. 150 NL/min 3000 NL/min PF2A703H 5.5 CFM 106.0 CFM 300 NL/min 6000 NL/min PF2A706H 10.5 CFM 212.0 CFM 600 NL/min 12000 NL/min PF2A712H 21.0 CFM 423.5 CFM : Analogue output is based on the rated flow range at normal condition. Displayed flow range is based on standard condition. Therefore, the range of rated flow and the displayed flow are different..

10 to 100 20 to 200 50 to 500 L/min L/min L/min L/min L/min Pressure Rated pressure range -50 kPa to 0.5 MPa -50 kPa to 0.75 MPa Proof pressure 1.0 MPa Output for PF2A3 Analogue voltage output (non-linear), Output impedance: 1 k Voltage output 1 to 5 V Output impedance 1 k Analogue output Current output 4 to 20 mA Load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600

. -19No.PF-OMO0014-D Output for PF2W3 + Analogue (4 to 20 mA) type PF2W5--2Analogue output: 4 to 20 mA Load impedance: 300 (12 VDC) 600 (24 VDC) 1: Refer to the PF2W3 operation manual for details of the flow monitor. 3: Load indicates analogue input equipment such as an ammeter. -20No.PF-OMO0014-D Troubleshooting Troubleshooting If an operation failure occurs with the product, use the chart

Min. load impedance: 100 k (Output impedance: 1 k) Analogue output Current output: 4 to 20 mA, Accuracy: 2%F.S. or less Max. load impedance: 300 or less with 12 VDC, 600 or less with 24 VDC Supply voltage 12 to 24 VDC 10% Power consumption (No load) 20 mA or less Enclosure IP65 Environment Operating temperature range Operation: 0 to 50 C, Storage: -25 to 85 C (no condensation or freezing

. -42No.PF-OMW0004-B Model PF3W704 PF3W720 PF3W740 Response time 6 0.5 s/1 s/2 s Analogue output Voltage output Output voltage: 1 to 5 V, Output impedance: 1 k Current output Output current: 4 to 20 mA Maximum load impedance: 300 for 12 VDC, 600 for 24 VDC Hysteresis Variable External input Voltage free input of 0.4 V or less (reed or solid state type) for 30 ms or longer 2-screen display

Analogue output 4 to 20mA Max. load impedance 600 -22No.LV50***-OMQ0002-G Example of wiring for accumulated pulse output NPN 2 output type LFEA NPN + Analogue output type LFEC LFED Black OUT1 Or Load White OUT2 (LFEA only) Load Blue DC(-) Brown DC(+) Black OUT1 Or Load White OUT2 Load PNP 2 output type LFEB * When accumulated pulse output is selected, the indicator LED will be turned OFF

NPT)1 3638 Nm NG NG 19 No.LFE*-OMY0008 NG IN 5 (5D)(68 ) 20 No.LFE*-OMY0008 FG 3 1 DC() 4 2 2 OUT2 3 DC() 1 4 OUT1 3 4 2 1 DC() 2 OUT2 3 DC() 1 4 OUT1 LFE M12 21 No.LFE*-OMY0008 NPN2 LFEA PNP2 LFEB DC() OUT1 OUT2 DC() OUT1 DC24V DC24V DC() DC() Max.28 V80 mA 1 V Max.80 mA 1.5 V NPN LFEC NPN LFED DC() OUT1 OUT2 DC() OUT1 OUT2 DC24V DC24V DC() DC() Max.28 V80 mA 1 V 420 mA 600