SMC Corporation of America
Elite Part Number Search
Search Results "MGCMB50-350-R"

0 2N o q Size e Equivalent lead w Motor mounting position t Motor option y Stroke adjustment unit (Included) Nil Top mounting U Bottom mounting T 48 mm 25 32 Nil Without option B With lock Nil None M Motor side only E End side only W Both sides Nil U r Stroke : Standard/: Produced upon receipt of order Stroke Model 50 100 150 200 250 300 350 400 450 500 550 600 700 800 900 1000 1100 1200

Port location on head cover 10, 16 Nil R Perpendicular to axis Axial direction Built-in Magnet Cylinder Model Suffix the symbol -A (Rail mounting style) or -B (Band mounting style) to the end of part number for cylinder with auto switch. For configuration, refer to page 10-3-7.

(Return spring normally closed) When the pilot solenoid valve i is not energized (or when air is exhausted from 12(P1) for air operated style), the valve body r connected to the piston y is closed by the return spring u.

Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.

Pilot port location Nil Front R Right L Left Pilot port Pilot port Pilot port Front Right Left Application Examples Lightweight workpieces such as electronic boards can be stopped, positioned and clamped with high accuracy. Stopper Positioning Clamping Space is reduced due to the integrated construction of a cylinder and linear guide.

A Cable length Standard Stroke M L Z 1 m 3 m 5 m Nominal size Standard stroke (mm) Made to Order Long stroke (-XB11) Stroke range (mm) The remote control type can be selected by adding the above symbols. 16, 25 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 601 to 1000 Strokes are manufacturable in increments of 1 mm, up to 1000 strokes.

How to order L E C C G R ii. Dimensions 40 8. Reference Information 8. 1 Checksum Calculation Procedure The checksum calculation is based on the LRC method. (1) All sent data is added, excluding the Start/End codes. (2) Subtract FFh from the last 2 bytes of the calculation result in step (1). (3) Add 1h to the calculation result in step (2). 8. 2.

The tightening torque should be 0.1 to 0.2 Nm. 5 to 6 14 e-Rodless Actuator Series E-MY2 Names and Functions of Individual Part Controller detail w t q u End Motor I/O cable Controller Power supply cable Slider i y e r Switch FG terminal Motor side end Description Content/Function q w e r t y u i Stroke learning switch Description Content/Function Switch to move the actuator to intermediate

Flow direction (Right Left) Nil Rc1/4 F G1/4 *1 Nil Flow direction (Left Right ) R Flow direction (Right Left) *1: Conforming to ISO16030 *1: Conforming to ISO16030 Square embedded type pressure gauge Round type pressure gauge Refer to the WEB catalog for details.

Description Material Note 1 Stud Carbon steel Zinc chromated q w t r y u 2 Bowl Aluminum alloy Chromated 3 Socket Carbon steel Zinc chromated e 4 Ring Rolled steel Nitriding treatment 5 Slider Rolled steel Nitriding treatment 6 Plate Rolled steel Zinc chromated 7 Dust cover Synthetic rubber Replacement Part No. Description Part no.

Port location on head cover 10, 16 Nil R Perpendicular to axis Axial direction Built-in Magnet Cylinder Model Suffix the symbol -A (Rail mounting style) or -B (Band mounting style) to the end of part number for cylinder with auto switch. For configuration, refer to page 10-3-7.

Description Body Note Baking finish Material q Aluminum alloy w w Aluminum alloy Baking finish Housing e Aluminum alloy Baking finish Drain guard y r Foam rubber Float IN t Stainless steel + Rubber Pilot valve y Resin Lever u Brass Flushing button t i Orifice r o Rubber Diaphragm Replacement Parts 10-1 e No. Description Part no. ADH-D400 Note 10-2 !

Port location on head cover 10, 16 Nil R Perpendicular to axis Axial direction Built-in Magnet Cylinder Model Suffix the symbol -A (Rail mounting style) or -B (Band mounting style) to the end of part number for cylinder with auto switch. For configuration, refer to page 10-3-7.

If the leakage volume is 5 /min (ANR), the vacuum pressure of the S type is 80 kPa r t y, and for the L type it is 47 kPa r' t' y'. Thus, if the leakage volume is 30 /min (ANR) the L type can attain a higher vacuum pressure, and if the leakage volume is 5 /min (ANR), the S type can attain a higher vacuum pressure.

(A) 2 0.7MPa 0.15MPa 1.8 (0.1) 10HZ 3 (R) 1 (P) 3 (R) 1 (P) Refer to Best Pneumatics (1) Page 2.2-1 Mist Separator Series AM Specifications Models Model Compressed air 1.0MPa 0.05MPa Fluid AM150 AM250 Maximum operating pressure Rated flow rate l/min (ANR) 300 750 Note 1) Series AM separates and removes the oil mist in compressed air which is troublesome for ordinary filters, and removes fine

Calculate the area of the cylinder piston Area = r2 where = 3.1416 r = 12 the bore diameter 2. Multiply the piston area by the air pressure to be used. Area x Pressure = Force Output Example: What is the theoretical force output of a 2 12 bore cylinder operating at 80 lbs. per square inch air pressure? Step 1.

Calculate the area of the cylinder piston Area = r2 where = 3.1416 r = 12 the bore diameter 2. Multiply the piston area by the air pressure to be used. Area x Pressure = Force Output Example: What is the theoretical force output of a 2 12 bore cylinder operating at 80 lbs. per square inch air pressure? Step 1.

(mm) 3 5 6.5 8 Black (B) White (W) Red (R) Burst Pressure Characteristics Curve and Operating Pressure Blue (BU) Green (G) Burst pressure (MPa) Fluid Air/Water Other than TSR0603 Max. operating pressure (at 20C) 1.2 MPa Refer to the burst pressure characteristics curve.

CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.