SMC Corporation of America
Elite Part Number Search
Search Results "MGCMB25-500-R"

Port size 10 8 6 12 1/8" 1/4" 3/8" 5/32" 3/16" 5/16" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure

Metric Inch Model Port size 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 X 0.8 R(PT)1/8 R(PT)1/4 R(PT)1/4 R(PT)3/8 R(PT)1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT1/2 Specifications Proof pressure 1.5MPa Max. operating pressure 1MPa JIS symbol

Set pressure range -0.105 to 1.050 MPa -105.0 to 105.0 kPa 10.0 to -105.0 kPa Power-saving function Withstand pressure 1.5 MPa 500 kPa 500 kPa The display can be turned off to save the power consumption. 0.1 kPa 0.001 MPa 0.1 kPa Min. unit setting The value disappears and decimal points start flashing.

0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min (ANR)] IW215 Flow rate characteristics IW222 Flow rate characteristics Supply pressure: 0.7 MPa 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 100 300 400 200 600 500 Supply pressure: 0.5 MPa 0.25 0.2 Set pressure [MPa] Set pressure [MPa] 0.15 0.1 IP 0.05 IW IW 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min

Note 3) A particulate generation test has been conducted in a vacuum environment of 10-Pa. a t e l u g c 2 Stainless steel linear guide & low particulate generation vacuum grease e i t n r a e p r a 0.0 10 0 20 10 w t i o o n L Operation cycles a t e l u g c e 1 i t n r a e Particulate generation from the linear guide unit has been reduced with the use of a stainless steel linear guide and

06 ZZR1 R 1 R1 ZR1 1 1 RV ZR1 Port location Stations R L Left side Right side 01 1 Arrangement (Right valve station which is looked from valve side is first station.) Arrangement (Right valve station which is looked from valve side is first station.)

Note 3) A particulate generation test has been conducted in a vacuum environment of 105 Pa. a t e l u g c Stainless steel linear guide & low particulate generation vacuum grease e i 2 t n r a e p r a 0.0 10 0 20 10 w t i o o n L Operation cycles a t e l u g c e i t n 1 r a e Particulate generation from the linear guide unit has been reduced with the use of a stainless steel linear guide and

d 5 i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.

500 1000 1500 2000 0 500 1000 1500 2000 mm mm Installation distance [mm] Installation distance [mm] 6-3.

500 0 0 0 10 20 30 40 0 10 20 30 40 Circullating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR050-A/W-20-) 9.5.2 HRR050-A/W-402000 2000 Ambient temp Ambient temp 1500 1500 Heating capacity[W] Heating capacity[W] 40 40 32 32 25 25 1000 1000 5 5 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature[] Circulating fluid temperature

Operating the cylinder by connecting the piping directly to the cylinder can cause the piston speed to exceed the maximum operating speed of 500 mm/s. Therefore, to operate the cylinder, make sure to use an SMC speed controller and adjust the piston speed to 500 mm/s or less.

(A) 2 4.5(0.25) 9.0(0.5) Refer to Best Pneumatics Vol. 4 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Specifications Mist separator Series AM Model Compressed air 1.0 MPa 0.05 MPa 1.5 MPa 5 to 60C 0.3 m (95% filtered particle diameter) Fluid Max.operating pressure Model AM150 AM250 Rated flow l/min (ANR) 300 750 Min. operating pressure (1) Proof pressure Port

Functional option With end lock (R) Axial piping (P) For details of adjuster and functional options, please refer to "Optional specifications" on page 46. IN OUT Theoretical Output Table The dual rod ensures an output twice that of existing cylinders.

R 59 Sa Sb T 500 U 250 V 310 Model ZH30--X185 ZH40--X185 28.5 146.5 M4 x 0.7 10 203 90 64 25 27.2 33.5 196.8 74.5 6 90 78 6.5 92 47 2.3 42 Rc3/8 76 500 250 310 Note 1) This thread portion is intended to adjust the product characteristics.

Operating the cylinder by connecting the piping directly to the cylinder can cause the piston speed to exceed the maximum operating speed of 500 mm/s. Therefore, to operate the cylinder, make sure to use an SMC speed controller and adjust the piston speed to 500 mm/s or less.

(R) EEPROM = Memorize data although power is off. (R/W) RAM = Actual memory the SI unit is working with. (R/W). 1. Reset node, Reset com or Power cycle: EEPROM is copied into RAM 2. STORE: Copy RAM (with modified/non modified values) into EEPROM 3.

Standard stroke Maximum manufacturable stroke (mm) Standard stroke (mm) Bore size (mm) Suffix for stroke adjusting unit 25 32 40 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000 2000 2000 2000 Nil S 2 pcs. 1 pc.