[Unit: mm] If the current position is within the range between the W area end 1 and W area end 2, the WAREA will be turned ON. * If W area output end 1 >W area output end 2, the alarm Parameter W-AREA1 XX Stroke (-) to Stroke (+) of the basic parameter ALM will be activated.
. = 2.5 mm only, w/threads w e u i Stainless steel Lever Packing O-ring NBR Valve Retainer Spring r POM o NBR t Stainless steel !
(g) n: Stations W = 30n + 50 W = 37n + 63 W = 61n + 101 W = 79n + 127 W = 100n + 151 Note) For more than 10 stations, supply pressure to P port on both sides and exhaust from EA and EB port on both sides.
fluid level gauge Facility water outlet (Rc1/2 w/plug) Facility water circuit Level switch Facility water inlet (Rc1/2 w/plug) Press.
A R W R a n g e M O D E < 2 . 2 C 1.0 ARW: Anti Reset Windup 5. I Constant Setting range : 1 to 999sec Min. increment : 1sec Indicated content : I constant(Ex. : 150sec) Function : Sets integral time used for PID control. I C o n s t a n t M O D E < 5 0 C 150 sec 7-9 Operation 6.
If W-AREA1 >W-AREA2, the "Parameter ALM" alarm will be Basic parameter "Stroke (-)" W-AREA1 W-AREA1 "Stroke (+)" Basic parameter "Stroke (-)" W-AREA2 W-AREA2 activated. However if W-AREA1= W-AREA2 = 0, WAREA will be OFF and no alarm will be generated.
Temperature rise 2 (B) 1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 12.7 VA (50 Hz), 10.7 VA (60 Hz) 7.6 VA (50 Hz), 5.4 VA (60 Hz) 1.8 W (without light), 2 W (with light) 4.8 W (without light), 5 W (with light) Inrush VNB 10 (P2) Apparent power AC VNA11 VNA12 Holding SGC 12 (P1) 12 (P1) Power consumption DC External pilot solenoid VNC Non-locking push type Other (Option) Non-locking push type Manual override
(A contact) 50mm 75mm 100mm 125mm 150mm 170mm 200mm 50 75 100 125 150 170 200 N.O. (A contact) Use a driver with CE marking.
2 w y e u t !6 i o !7 B !3 B section MU25 Spring extend w i !0 o !8 t !5 q !7 r e u !1 !2 !6 y !4 A B !
Power consumption reduced 0.45 W 0.35 W CE compliant (Built-in solenoid valve/PB1011A) Check valve is resistant against foreign matter. Flow passage around the check ball is enlarged and improved for better resistance against foreign matter. Longer life [Life is 1.5 times longer than the current product.]
Calculation Example 1: MUB40-15S(T) Basic weight0.62kg 2 pcs. 5 10 15 15 Example 2: MUC50-5S(T) Basic weight1.06 Additional weight (mounting bracket)0.40 1.06 + 0.40 = 1.46 kg 1 pc. 5 5 10 15 Construction Component Parts No. q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !
P FR (2) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 FP Note 2) W/ end lock is not available in Series MXQ6.
) Q R Cooling water outlet 87 G (H) K J Cooling water inlet S T 2 x 2 x U Mounting holes D N Drain C (A) B (M) W Rc (mm) B C D E F G H J K L M N P Q R S T U V W Y Z 473 ZA HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 Model A 360 570 948 1354 1612 2112 1724 1 2 3 4 1 2 1 2 3 4 3 4 3 4 3 4 1 2 1 2 3 4 395 10 10 12 18 18 18 18 4.5 4.5 4.5 6.0 6.0 6.0 8.0 94 94 150 139 139 139
165 216 216 216 267.3 35 35 138 170 276 276 365 270 480 704 1056 1203 1703 1210 35 35 37 80 150 150 72 395 83 83 212 258 366 366 500 190 390 575 893 1038 1538 950 1 2 1 1 2 1 1 1 1 2 2 3 1 1 1 4 14-15-8
Size 32 40 Regardless of the stroke 2.128 [Nm] Affecting moment to the piston rod end Moment = W x L [Nm] 3.844 [Nm] 11-10-5 6 Technical Data 4: Air Consumption 8. Air consumption Results are determined by measuring the factors through 1 complete cycle over one minute.
(unit mm): When the current position is within W-AREA1 and W-AREA2, the WAREA output turns ON. When W-Area 1 < W-Area2, the Parameter ALM of alarm occurs.
Component Parts SY w Description Material N.C. Body Resin SYJ q (A) 2 Spool valve Aluminum/NBR w e r Pilot valve VK 1 (P) 3 (R) Port plug Resin/NBR VVQZ100-CP VZ VT VQZ200/300 VT Metal seal Rubber seal VP VG q r w e q r w e VP VQ VQZ N.C. N.C. VZ (A) 2 (A) 2 VS 1 (P) 3 (R) 1 (P) 3 (R) q r w e q r w e N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Component Parts No.
Peltier-type Chiller Thermo-con/ Compact Type Air-cooled Compact 130 mm x 210 mm x 150 mm Height Width Depth Low-noise design (at low load): 37 dB 130 mm 150 mm Display/Operation panel 210 mm Circulating fluid level gauge Dustproof filter Replaceable Cooling capacity: 220 W Superior temperature control Temperature stability: 0.1C Now only takes about 41 seconds to lower the temperature by