A rodless cylinder of the same stroke can be installed in a much shorter space ot approximately 600 mm. ll has particular advantages when very long strokes are required. The magnetic retaining force limits the force available trom a magnetically couplod type of rodless cylinder.

Vertical Mounting L L Mounting orientation m m Max. speed (mm/s) up to 200 up to 400 up to 600 up to 800 All strokes Stroke (mm) 6 10 15 Selection graph 1 2 3 4 20 25 32 Horizontal Mounting L Mounting orientation m m Refer to the caution notes below.

R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult P/A Customer Service for larger sizes.

PFA703H--28 PFA703H--68 PFA706H--28 PFA706H--68 PFA703H--29 PFA703H--69 PFA706H--29 PFA706H--69 3000 3000 150 150 6000 6000 300 300 PFA712H--28 PFA712H--68 PFA712H--29 PFA712H--69 12000 12000 600 600 19

Temperature characteristics Ambient temperature 5% F.S. (25C reference) Fluid temperature 5% F.S. (25C reference) Operating pressure range*2 0 to 1 MPa Proof pressure*2 2 MPa Analog output Response time*3 0.5 s Voltage output Output voltage: 1 to 5 V Output impedance: 1 k Current output Output current: 4 to 20 mA Max. load impedance: 600 Power supply voltage 24 VDC 10% Current consumption

or less (24 VDC) P2: Analog output 1 to 5 V Allowable load resistance 100 k or more P6: Analog output 4 to 20 mA Allowable load resistance 300 or less (12 VDC), 600 or less (24 VDC) 339 LLB Series Refer to the operation manual for how to set and to operate.

800 1000 0 0 200 400 600 800 1000 Kv value Volume ratio (Kv) (2) If your operating conditions are different from these basic conditions, apply a correction factor.

Reduced-wiring Fieldbus System Static Neutralization Equipment Autobalance sensor [Body-mounting type] Offset voltage of static neutralization area 150 Alphabetical Index Length Measuring/ Counter 100 Offset voltage (V) 50 0 return current + return current 50 100 Controls offset voltage of static neutralization area at a constant value. 150 0 300 600 900 1200 1500 1800 2100 Monitoring +

mode Variable from 0*2 Window comparator mode Short circuit protection Yes Voltage output Output type Voltage output: 1 to 5 V Voltage output: 0.6 to 5 V Output impedance Approx. 1 k Output type Current output: 4 to 20 mA Current output: 2.4 to 20 mA Analog output Current output Load impedance Maximum load impedance at power supply voltage of 12 V: 300 at power supply voltage of 24 V: 600

For details, refer to the optional accessory (page 11). 6 HEF Series Cooling Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 600 600 500 500 Cooling capacity [W] Cooling capacity [W] Ambient temperature 25C 400 400 Ambient temperature 25C 300 300 200 200 Ambient temperature 35C Ambient temperature

Cooling Capacity HRSE012-A-10-(T) [50 Hz] [60 Hz] 1600 1400 1600 Ambient temperature Ambient temperature 0 200 400 600 800 1000 1200 1400 25C Cooling capacity [W] Cooling capacity [W] 25C 600 800 1000 1200 HRS HRS 090 35C 35C 0 200 400 HRS 100/150 0 10 20 30 40 0 10 20 30 40 HRSH 090 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH HRSE018-A-10-(T) [50 Hz] [60 Hz]

length 300 mm) M: With lead wire (Lead wire length 300 mm) MN: Without lead wire Light/Surge voltage suppressor DC, AC specifications DC specifications Nil S Z R U Without light/surge voltage suppressor With surge voltage suppresser With light/surge voltage suppresser With surge voltage suppresser (Non-polar type) With light/surge voltage suppresser (Non-polar type) H: Lead wire length 600

Use only supplied cable and nut. 600 mm Maximum length for L-type 1000 mm 1500 mm 2000 mm 3000 mm 10 mm Semi-standard Warning Note) When placing an order for body ported solenoid valve as a single unit, mounting screws and gaskets for manifold are not included. Order them separately, if necessary. (For details, refer to page 18.)

63 1/4 35 32 27 90 38 20 70 11 9 21 14 58 11 72 M10 x 1.5 7 18 7 M18 x 1.5 109 176 69 to 600 80 3/8 40 37 32 100 50 25 82 11 9 28 20 71 13 89 M10 x 1.5 10 22 7 M22 x 1.5 130 210 80 to 750 100 1/2 40 37 41 125 60 30 100 14 10 29 20 71 16 110 M12 x 1.75 10 26 8 M26 x 1.5 131 212 100 to 750 Flange brackets and plug bolts are installed before shipment from factory.

35 32 27 75 32 20 58 9 9 21 14 58 11 58 M8 x 1.25 7 18 5.5 M18 x 1.5 55 1/4 109 176 63 Up to 600 35 32 27 90 38 20 70 11 9 21 14 58 11 72 M10 x 1.5 7 18 7 M18 x 1.5 69 1/4 109 176 80 RS Q G Up to 750 40 37 32 100 50 25 82 11 9 28 20 71 13 89 M10 x 1.5 10 22 7 M22 x 1.5 80 3/8 130 210 100 Up to 750 110 40 37 41 125 60 30 100 14 10 29 20 71 16 M12 x 1.75 10 26 8 M26 x 1.5 100 1/2 131 212

50, 63 -XA -XC6 Made of stainless steel 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 Tie-rod, cushion valve and tie-rod nut made of stainless steel -XC7 Note 1) Intermediate strokes not listed above are also available.

Arm length Shim Clamping position Bore Size: 25 Arm length: 100 mm 157 [700] Peak clamping force position 135 [600] Clamping force lbf [N] 112 [500] 90 [400] 116 psi [0.8 MPa] 67 [300] 0.5 MPa 73 psi [0.5 MPa] 45 [200] 22.5 [100] 0.3 MPa 44 psi [0.3 MPa] 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Shim thickness [mm] Bore Size: 32 Arm length: 100 mm 157 [700] 135 [600] Clamping force lbf [N] 0.5 MPa

, 700, 800 1300 12-CY3R40 40 Rc1/4 NPT1/4 G1/4 12-CY3R50 12-CY3R63 50 63 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special order.

50, 63 Bore size (mm) Contents Kit no. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.