Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.
) P=10.5 13.5 (L3) 3 L2 6 .5 L1 2 1 16 .5 Station 5.5 D side 2.3 2-M5 X 0.8 External pilot port (Only external pilot style(R)) 7.8(C3, C4, C6) 21.6 (M5: 5.7) 35 5.5 53 300 (Lead wire) Cover dia 1.6 Cross section 0.34mm2 (Top piping) 39.5 7.8 42.5 P R 1 3 15 8 2-M5 X 0.8 PE port 13.4 2-Rc(PT)1/8 R(EXH) port 16.3 The broken line indicates DIN rail mounted style [-D]. 41.2 2-Rc(PT)1/8 P(SUP)
P.52~60 LJ1H303PAK LC1-1B3V LJ1H303NAK Dedicated Teaching Box LC1 Series .P.61 LJ1S101SCLC1-1B1S P.61, 62 LC1 Series. P.63 LC1 Series Options. P.64 Catalog Terminology. P.71, 72 LJ1, LC1 Inquiry Sheet. LJ1S202SCLC1-1B2S LJ1S303SCLC1-1B3S Features 4 Series LJ1 Electric Actuator Selection Procedure Various operating conditions must be considered in order to select an electric actuator.
Swivel Elbow KFG2V Metric Inch P. 324 P. 329 Metric Inch P. 325 P. 331 KDM KB KR KA KQG2 Straight Union KFG2H Female Connector KFG2F KG Metric Inch P. 324 P. 330 Metric Inch P. 326 P. 331 KFG2 KFG2 MS KKA KP LQ Union Tee KFG2T Union Nut KFG2N MQR Metric Inch P. 324 P. 330 Metric Inch P. 326 P. 331 T IDK 321 Stainless Steel 316 Insert Fittings Applicable Tubing: Metric Size, Connection Thread
+ + 38.7 25.5 A A 19.2 9.4 21 (Pitch) P=17 21 1/8 (A port) 19.2 9.4 A A 18.5 (Pitch) P=16 21 M5 x 0.8 (A port) L plug connector (L) M plug connector (M) DIN terminal (D) M8 connector (WO) 49 49 49 49 P R P R P R P R 57.2 [59.4] 67 [69.2] 52.2 58.7 66.1 76.1 Max. 10 77 Pg7 65.2 [72.2] Approx. 300 (Lead wire length) 41.1 M8 x 1 58.6 68.1 Approx. 300 (Lead wire length) 38.7 79.4 54.1 [61.1]
(C ) Temp. conditions Power source 1.0 High temp. water (X, E, N, P) 60 40 5 0.82 0.20 0.20 Water (Std.) Oil (D. N) Steam (S,Q) Oil (Std.) VX3235-00 VX3335-00 3 1.1 0.25 0.27 AC DC 60 40 1 99 60 120 183 Maximun VX3245-00 40 1.6 0.20 0.38 4 20 VX3345-00 Minimum AC, DC Ambient temperature (C ) 40 10 Operating fluid temp.
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.
(c)BUSY ONINP OFF No. () (d)INP ONBUSY OFF INP ON BUSY OFF (INP ONBUSY OFF) 2 ABS 75 No.SFOD-OMT0009CN-B (3) --(a)No.(INx) (b)DRIVE ON Min.15ms No.(OUTx ) No. No. (c)BUSY ONINP OFF (d)INP ON 2.5[s] ALARM ON( ) BUSY OFF INP ON BUSY OFF 1)(0-149) 2)(d) 2 ABS 76 No.SFOD-OMT0009CN-B (4) HOLD --(a)(BUSY ON)HOLD ON (b)BUSY OFF () No. (c)HOLD OFF No.
(100) (2)2mm 2 D (3) 40 50mm ()100mm 100 -33No.JXC-OMT0001CN-C 5.
Printed in Japan. 1st printing September, 1999 D-SMC.L.A. P-80 (D)
( ) 5H9 depth 5 +0.030 0 n x 5.5 6 60 150 D x 150 (= E) B 15 15 Note 1) When mounting the actuator using the body mounting reference plane, set the height of the opposite surface or pin to be 3 mm or more because of round chamfering.
(Including bracket, screw) Applicable bore size (mm) 40 BMU2-040 50 BMU2-040 63 BMU2-040 Cylinder series MDU 8-30-60
61 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Tie-rod Mounting Style
(Including bracket, screw) Applicable bore size (mm) 40 BMU2-040 50 BMU2-040 63 BMU2-040 Cylinder series MDU 8-30-60
61 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Tie-rod Mounting Style
(Including bracket, screw) Applicable bore size (mm) 40 BMU2-040 50 BMU2-040 63 BMU2-040 Cylinder series MDU 8-30-60
61 Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Tie-rod Mounting Style
Model Model Model Port size R(PT) Effective area (mm2) Weight (g) Dimensions (mm) Weight Effective area Port size Model Dimensions (mm) R(PT) (mm2) (g) AN200-02 35 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233 74 60 820 263 86 70 A B D A B D 1 4 1 4 AN202-02 35 16 64 22 19 33 84 28 24 47 95 34 24 AN300-03 60 3 8 AN302-03 60 3 8 AN402-04 90 1 2 AN400
ZZ + Stroke Model B C D E(h8) I K L NA Q x R S TC x R W X ZZ REA50 REA63 0 86 32 53 30-0.033 32-0.039 58.2 25 110 55 M8 x 1.25 x 16 176 M12 x 1.25 x 7.5 60 60 180 100 38 66 72.2 26 122 69 0 M10 x 1.5 x 16 188 M14 x 1.5 x 11.5 70 70 192 Mounting nuts/2pcs. packaged with each cylinder d C H d B C Part No.
) Oil (Standard) (D, E) High temperature oil (3) (S) (D) 99 100 183 AC DC AC DC 60 40 80 60 60 40 40 60 Maximum Minimum 1 10 5 (2) 10 (1) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E etc. in parentheses are option symbols.
D-A80 =U B + First-stage stroke =U B A D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-Y7NTL D-F7BAL B + First-stage stroke =U SMC =U B A D-A73C D-A80C D-J79C B + First-stage stroke =U =U B A D-A79W D-F7WV D-F7V D-F7BAVL B + First-stage stroke =U SMC =U B A 11 3 Position Cylinder Series RZQ D-A9 D-F9 D-F9W D-A9V D-F9V D-F9WV D-F9BAL B =U =U A B + First-stage stroke 50 or larger bore size D-P5DW
Unit: g Model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Auto Switch Dimensions Auto Switch Internal Circuit D-M9 M2.5 x 4l mounting hole Slotted set screw Indicator light D-M9B, N, P D-M9N DC(+) Brown 2.6 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC(-) Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC(+) Brown 22
-X430 -X440 Environment Low temperature High temperature Ambient temperature [C] 30 to 60 5 to 80 Fluid temperature [C] 5 to 60 (with no freezing) Made-to-order part no. -X425 Proof pressure [MPa] 3.0 Maximum operating pressure [MPa] 2.0 Material Rubber parts Special NBR FKM Main parts Metal (Aluminum die-cast, etc.)