SMC Corporation of America
Elite Part Number Search
Search Results "IS10E-20-01-L-D"

Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Only for ZSE40(F)/ISE40--30/70(L)-M, displays the input mode and the compensation value alternately. If auto shift input is not complete, zero is displayed. 16-2-20 7 Series ZSE40/ISE40 High Precision, Digital Pressure Switch Unit Set Output Type It's only subject to ZSE40(F)/ISE40--(L).

140 160 180 200 Flow rate (slpm, N2) AZ1000 100 psig (0.69 MPa) 40 psig (0.28 MPa) Inlet pressure: 80 psig (0.55 MPa) 20 psig (0.14 MPa) 1.5 (38.1) 50 0.34 2.25 (57.2) 40 0.28 Delivery pressure (MPa) Delivery pressure (psig) 30 0.21 0.69 (17.5) 20 0.14 2.00 (50.8) 10 0.07 A 0 0.00 0.88 (22.4) 0 20 40 60 80 Flow rate (slpm, N2) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) Connections inch

Setting range 100.0 to 100.0kPa 101.3 to 101.3kPa 1.000 to 1.000MPa Set pressure range 100.0 to 100.0kPa 10.0 to 101.3kPa 0.1 to 1.000MPa Lead wire length Nil L 0.6m 3m 2 High Precision Digital Pressure Switch Dimensions ZSE40(F)/ISE40 01 T1 20 30 M5 x 0.8 thread depth 5 MPa 30 20 OUT2 OUT1 SET Width across flats 12 2-M3 x 0.5 thread depth 4 6.4 18.35 Atmospheric release port Lead wire length

Adjustable Roller Lever/VM830-01-13 JIS Symbol 20N F.O.F. At lever length 38.1mm 20 P.T. 30 O.T. 50 T.T. Adjustable Rod Lever/VM830-01-14 JIS Symbol 2.3N F.O.F.

(Example) For 6 stations 06 How to Order (Single unit) ZFA 100 01 Bracket Air suction filter Symbol Nil L None Bracket ZFA100 1 pc. on the left R LR Body type 1 pc. on the right With both the left and right sides 100 Filtration area (mm2) Symbol L or R shows the left or right of the filter IN when viewed from front. 2110 4210 200 Port size Thread type Applicable model Symbol 02 01 Port

The result is approximately 10 L/min (ANR). Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.

These i nst ruct i ons i ndi cat e t he l evel of pot ent i al hazard w i t h t he l abel s of CAU TI O N W ARN I N G or D AN G ER . To ensure saf et y, be sure t o observe I SO 4414 and ot her saf et y pract i ces. D ef i ni t i on Label M eani ng of l abel W ARN I N G O perat or error coul d resul t i n seri ous i nj ury or l oss of l i f e.

0.14 2.25'' (57.2) 18 0.12 16 0.11 0 20 40 60 80 100 Flow rate (slpm, N2) .69'' (17.5) 2.00'' (50.8) A A Connections in A mm FV4 MV4 FV6 MV6 1.85 01 47.0 2.35 01 59.7 Hastelloy is a registered trademark of Haynes International.

Construction ARJ310-01 ARJF310F-01 y e !

Stations: 01 (1 Station), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 03 (3/8)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 01 (Rc1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: 01 (Rc1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: 01 (Rc1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: N (w/o Lead Wire w/Connector)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)