Station 3 2 1 D side U side Stations 02 03 2 stations 3 stations 20 20 stations Note) Maximum of 20 stations Electrical entry Grommet/Plug lead C How to Order Valve S070 A 5 B G Electrical entry Body type Body type Base mounted with clips Symbol A G C Grommet Plug lead with light/surge voltage suppressor Coil voltage Power consumption Pressure specification Flow rate 24 VDC 12 VDC

Actuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 5. Pressure (including vacuum) holding It is not usable for an application such as holding the pressure (including vacuum) inside of a pressure vessel because air leakage is entailed in a valve. 6.

) 2-4.5 (mounting holes) 67.5 59 19 17 2 R P P R 34 2.3 7 20 Pg.7 4-Rc(PT) 1/8 (ports P, R) A A A P = 19 13.5 L2 L1 4 1 7 8 26 47.5 Approx. 300 (lead wire length) n-Rc(PT) 1/8, M5 x 0.8 (port A) 7 20 34 2-4.5 (bracket mounting holes) 4-M3 x 0.5, depth 6 (bracket mounting screws) 7 8 47.5 15.5 20 25 49 4 L3 7 7 L: Dimension table n: Stations n L 1 35 27 13 2 54 46 32 3 73 65 51 4 92 84 70

Stations PFA Port size Orifice diameter 3/8 1/2 3/4 1/4 Valve type Symbol Type 8 12 20 4 Basic type N.C. P P P Stations are counted from station 1 on the left side, with the A (OUT) ports in front. PA PB PA P PB A A A N.O. PA PB PA A (OUT) port PB A A A Double acting N.C. N.O. Double acting LLA2A-03-02-C 1 set 1 set Manifold base part no.

When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

Note 3) When tightening an auto switch mounting screw (M2.5), use a watchmakers screwdriver with a grip diameter of 5 to 6 mm. Also, set the tightening torque to be 0.05 to 0.15 Nm. As a guide, turn 90 from the position where it comes to feel tight.

Avoid especially the application of pressure above specifications through a water hammer. a) Use a device such as a water hammer relief valve to slow the valves closing speed. b) Absorb impact pressure by using an accumulator or elastic piping material such as a rubber hose. c) Keep the piping length as short as possible. 7.

For AIR EXH: AN20-02 (: Either Nil or N is entered as a thread symbol.)

upper limit of the power supply voltage is 24 VDC. *5 The accuracy value is based on dry air as a fluid.

800) 258-9200-www.stevenengineering.com 5.5 5.5 5.5 6.5 1 pc. 2 pcs. 20 20 20 20 20 20 CNA The operating ranges are provided as guidelines including hystereses and are not guaranteed values (assuming approximately 30% variations).

single knuckle joint, which may be used as a guide.

When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.

It is important to understand that one may follow this guides recommendation, yet have a failure due to a parameter specic to the given application, as noted.

Manifold Specifications Porting specifications Maximum number of stations Series Port location Port size 1(P), 3(R) 4(A), 2(B) C8 C3, C4, C6, M5 12 stations (24 as an option) SQ1000 Side, Top Flat Ribbon Cable (26 pins, 20 pins) U side Cable assembly 1 2 3 stations AXT100-FC 1 2 3 20 26 D side Type 26P flat ribbon cable connector assemblies can be ordered with manifolds.

Compact Rotary Actuator Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Compact Rotary Actuator Rack-and-Pinion Type/Sizes: 10, 15, 20, 30, 40 Series CRQ2 Piping can be installed from one end Body can be used as a flange Compact design saves mounting space Uses internal cushioning 10, 15 : Rubber bumper 20, 30, 40: Air cushion 10: 17mm 15: 20mm 20: 29mm 30: 33mm 40: 37mm 2 auto

-2 wBQ2-012 Two types of auto switch mounting bracket are used as a set.

Series Dimensions: Universal Type Seal method: Gasket seal For M5, 10-32UNF Applicable tubing O.D. d Y W1 AS-F D3 D1 TMH ASD M L3 L4 AS L5 A AS-FE D2 KE AS-FG AS-FG AS-FP L2 L1 T H (Width across flats) AS-FM AS-D Metric Size [mm] AS-T Model d T H D1 D2 D3 L1 L2 L3 L4 L5 A M W1 Y Weight [g] Unlocked Locked Unlocked Locked AS131FSG1-M5-23 3.2 ASP 11.6 19.4 17.5 33.8 39 36.5 35 33.5 13.3 13.6

Use this as a standard when mounting, etc. Misc.

Use this as a standard when mounting, etc. Misc.