SMC Corporation of America
Elite Part Number Search
Search Results "HF3-JSX11-SN201N-BWN-D-B"

cable O.D. 6.8 to 9.6) Hs Hs 49 Ht Ht 56 34 36 A B B 33 A D-A3C D-G39C/K39C D-G5/K59 D-G5W/K59W D-G5BA D-G59F/G5NT G 1/2 (Applicable cable O.D. 6.8 to 9.6) B A HW 49 Hs Hs 24.5 B A 33 36 D-F5/J59 D-F5NT D-F5W/J59W D-F5BA/F59F D-A44 G 1/2 (Applicable cable O.D. 6.8 to 11.5) Hs Hs 31.5 Ht Ht 56 A 36 B B 30 A D-A44C G 1/2 (Applicable cable O.D. 6.8 to 11.5) B A HW 49.5 Hs 36 692 Auto Switch

(b)(SW1) 164( (3)(c)) (SW1) 8 7 6 9 A 5 B 4 C 3 D 2 1 0 F E (c) 0 1 0 17 1 2 1 18 2 3 2 19 3 4 3 20 4 5 4 21 5 6 5 22 6 7 6 23 ON ON 7 8 7 24 8 9 8 25 1 2 3 4 1 2 3 4 9 10 9 26 A 11 A 27 B 12 B 28 C 13 C 29 D 14 D 30 E 15 E 31 F 16 F 32 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D

Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height 20/25 D-A9V D-M9V D-M9WV D-M9AVL D-A9 D-M9 D-M9W D-M9AL B Approx. Hs A 32 to 100 D-A9V D-M9V D-M9WV D-M9AVL D-A9 D-M9 D-M9W D-M9AL B Approx.

. 10-12-25 Series CE1 Proper Auto Switch Mounting Position (Detection at stroke end) Auto switch A B Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5

. 10-12-25 25 Series CE1 Proper Auto Switch Mounting Position (Detection at stroke end) Auto switch A B Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5

(page 139) -140No.PF-OMA1007-B Standby regulator type NO specification AMS20/30/40/60B-R/N/F#D Part number P A B C D E J M L AMS20B-#D 1/8 1/4 301.8 214.7 85.1 66.8 25.6 46.2 24 40.1 AMS30B-#D 1/4 3/8 348.3 214.7 102.1 86.5 29.1 46.2 30 40.1 AMS40B-#D 3/8 1/2 395.8 214.9 119.4 91.5 32.6 46.2 36 40.1 AMS60B-#D 3/4 1 491.8 214.8 118 125 42.1 46.2 46 40.1 : Dimension D is the dimension

, D-C8 A 8.5 D-H7, D-H7W, D-H7F 8.5 A Hs B Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches

phase J B C D A A COM COM COM B 12 VDC GND F.G.

, D-F5W D-J5, D-J59W D-F59F, D-F5BAL D-Z7, D-Y59, D-Y7BAL D-Z80, D-Y69, D-Y7W(V) D-Y7P(V) D-A5 D-A6 D-A59W D-F5NTL D-A3, D-G39 D-A44, D-K39 D-P5DWL Bore size (mm) MB A B A B A B A B A B A B A B MB1 32 0 10.5 1.5 14 9.5 22 4.5 17 2 14.5 0 10.5 1 13.5 40 0 21.5 1.5 25 9.5 33 4.5 28 2 25.5 0 21.5 1 24.5 CA2 50 0 23 2 26.5 10 34.5 5 29.5 2.5 27 0 23 1.5 26 63 0 28 2 31.5 10 39.5 5 34.5 2.5 32

B A C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

DY#B (Unit 3) byte 9 Remote registration information (Wireless channel 8-15) Reserved DY#B (Unit 3) byte 10 DX#D (Unit 1) Remote (Wireless channel 002) byte 11 Reserved Base byte 12 Reserved byte 13 Reserved byte 14 DX#D (Unit 1) byte 15 byte 16 AXA (Unit 2) byte 17 Remote (Wireless channel 001) byte 18 byte 19 byte 20 Reserved byte 21 Reserved DX#D (Unit 1) byte 22 byte 23 DX#B (Unit 2)

Spacer: Y300 Bracket 158 240 190 190 172 172 AME250C AMF250C-B AME250C 156 236 AMH250C-B AMH250C-B Spacer D Center of IN/OUT ports C 1 X-X B X RELEASE Y200 Y400 2 X Model Model A B C D Seal AFF2C, AM150C AFF4C, AM250C AFF8C, AM350C AFF11C, AM450C AFF22C, AM550C Y200 Y300 Y400 Y500 Y600 18.5 48 3 35.5 4 47 26 59 57 31 65 5 A 75 5 61 33 (Spacer width) 41 86 6 75.5 Replacement Parts Part no.

D-C7 Proper auto switch mounting position (Detection at stroke end) D-H7A1/H7B Auto switch 8.5 Auto switch 8.5 16 16 approx. Hs approx. Hs A 29 B A 26 B (mm) D-C73 A D-H7A1/H7B B Hs A B Bore size Hs 7 6 22.5 6 5 22.5 7 6 25 6 5 25 8 7 28.5 7 6 28.5 14 12 32.5 13 11 32.5 20 25 32 40 Note) The above values should be used as a guide for detection at stroke end.

DY#B (Unit 3) byte 9 Remote registration information (Wireless channel 8-15) Reserved DY#B (Unit 3) byte 10 DX#D (Unit 1) Remote (Wireless channel 002) byte 11 Reserved Base byte 12 Reserved byte 13 Reserved byte 14 DX#D (Unit 1) byte 15 byte 16 AXA (Unit 2) byte 17 Remote (Wireless channel 001) byte 18 byte 19 byte 20 Reserved byte 21 Reserved DX#B (Unit 1) byte 22 byte 23 DX#D (Unit 2)

Auto switch capable Bore size Standard Stroke 1.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20 2, 2.50 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24 3.25, 4 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 24, 28 How To Order NC D A1 B 150 0400 A XC9 Adjustable Stroke Retract Auto Switch Mounting Bore Stroke Adjustment Range A: 0~1 B: 0~2 Dimensions d (in) Bore (in) MM KK A AA B C D DD E

Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7V D-F7WV D-F7BAVL Approx.

(Same surface) 10.5 16.5 D-A93 50 50 50 D-M9B D-M9BW D-B54 50 50 75 8.5 Auto Switch Mounting Position and Its Height Unit: mm Auto switch set value and its height 50 7.5 30.5 40 11.5 34.5 40 2 25 43.5 Auto switch D-B54 Symbol 63 7.5 30.5 47 11.5 34.5 47 2 25 50.5 40 11 23.5 34.5 15 27.5 34.5 5.5 18 38 32 3 30.5 30 7 34.5 30 0 25 33.5 Hs A B Hs A B Hs A B Hs B A 33 D-A93 D-M9B D-M9BW 24.5

D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 50 1.5 4 2 4.5 0 1 10 12.5 5 7.5 2.5 5 0 1 CL1 63 1.5 4 2 4.5 0 1 10 12.5 5 7.5 2.5 5 0 1 80 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5 4

switch Auto switch Ht Ht A A 32 B B L 9-6-20 21 Series MNB Cylinder with Lock Double Acting, Single Rod Proper Auto Switch Mounting Position D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5

Refer to ) 3) Remove the junction box B (top) for all stations using a precision screwdriver. (Refer to ) (Remove the junction box B from D side.) 4) Remove all connectors mounted to the junction box B. (Be careful not to break the connector clip.) 5) Remove the tension bolt. 6) Remove the end plate D assembly. 7) Remove the connector housing assembly from the end plate D assembly.