Set value input mode Press the "SET" button to display "P1-20" 1. The output OUT1(1) set value input mode is selected. 1: The set value of P1 is -20 ZSE3/ISE3(L) kPa RESET SET LED Bottom hold mode Pressing the button when pressure is displayed enables the lower limit peak value (value with low vacuum) to be held. In this case "d" is displayed on the LCD.

Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum

Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/

Body/Exhaust Type: For Manifold - Common Silencer Exhaust, Nominal Nozzle Size: ø1.0, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs, Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1

Body/Exhaust Type: For Manifold - Individual Port Exhaust, Nominal Nozzle Size: ø1.0, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V, Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch

Body/Exhaust Type: For Manifold - High-noise Reduction Silencer Exhaust, Nominal Nozzle Size: ø1.5, Supply Valve and Release Valve: N.C. / N.C., Rated Voltage: 24 VDC, Vacuum Sensor: Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs, Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port

5 10 5 10 5 10 5 10 5 10 5 10 10 20 11 9.7 20 20 27 27 29 29 29 29 29 29 83 83 2.9 2.8 3.9 3.9 5.3 5.9 9.8 9.8 20 20 20 20 24 24 Spring return Spring extend 12 63 76 87 101 16 125 145 20 196 217 357 426 25 29 35 32 43 50 67 78 40 92 104 50 135 151 206 223 374 429 Single acting, Spring extend Spring state with first mounting load Spring state with second mounting load

10 5 10 5 10 10 20 12 50 412 742 1072 16 20 25 32 Weight 40 (g) Weight 50 Action Bore size (mm) Cylinder stroke (mm) (N) Single Acting, Spring Extend 5 10 15 20 Bore size (mm) Stroke (mm) Spring reaction force (N) Second First 12 16 20 25 32 40 50 12 16 20 25 32 40 50 29 35 42 51 2.9 2.8 3.9 3.9 5.3 5.9 9.8 9.8 20 20 20 20 24 24 11 9.7 20 20 27 27 29 29 29 29 29 29 83 83 5 10 5 10 5

. 9-1 9.1.2 HRLE090-A-20. 9-2 9.1.3 HRLE050-W-20. 9-3 9.1.4 HRLE090-W-20. 9-4 9.1.5 HRLE090-A-40. 9-5 9.1.6 HRLE090-W-40. 9-6 9.2 REFRIGERANT AND GWP VALUE . 9-7 9.3 DIMENSIONS . 9-8 9.3.1 HRLE050-A-20. 9-8 9.3.2 HRLE050-W-20. 9-9 9.3.3 HRLE090-A-20/40. 9-10 9.3.4 HRLE090-W-20/40. 9-11 9.4 FLOW DIAGRAM . 9-12 9.4.1 HRLE050-A-20-*,HRLE090-A-20/40. 9-12 9.4.2 HRLE050-W-20-*,HRLE090-W-20/40.

C HRZ008-L1-F 16 14 [HRZ008-L1-F] Cooling capacitykW 12 10 8 6 4 2 0 -20 -10 0 10 20 30 40 Circulating fluid setting temp.deg.

. 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100A20 CH1 . 8-7 8.4.2 HRL200A20 CH1 . 8-7 8.4.3 HRL300A20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8-9

35oC 20 15 10 5 0 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Fig. 9-18 Cooling Capacity (HRL200-W-40 CH1) HRL Series 9.4 Cooling Capacity 9-17 HRX-OM-X037 Chapter 9 Documents 9.4.13 HRL100/200-W-40 CH2 3.0 2.5 Cooling capacity [kW] Ambienttemperature 45oC or less 2.0 (Max. 1.5 kW) 1.5 Rated 1.0 kW 1.0 0.5 0.0 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Up to

MPa 24 SMC 32.5 20 0.5 0.1 0.3 24 56 17 17 5.

MPa 24 SMC 32.5 20 0.5 0.1 0.3 24 56 17 17 5.

Body Size: 40, Type: B (Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: SA [Standalone (When Wireless Adapter is Connected: Wireless Remote)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual), Made to Order Option: X102 (Hub and Relief Valve only)