With 1 shock absorber (Set on the driving cylinder side when packed.) 25 B 32 BS 40 Standard stroke Long stroke * Refer to p.3.8-10 for minimum strokes for auto switch equipped style. Applicable auto switches/Refer to p.5.3-2 for further information on auto switch.

1000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 1900 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 1900 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 1900 125 2000 Made to Order (For details, refer to pages

500, 600, 700, 800 Oversized rod cylinder XB5 125 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (150C) XB6 Intermediate strokes are available.

2000 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 2000 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 100 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 2000 Intermediate strokes are available. *1 Please consult

VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized

VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized

VAC for 1 minute between external terminals and FE Insulation resistance 500 VDC, 10 M or more between external terminals and FE 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized

Positions/No. of solenoid Effective area (mm2) (Cv factor) Detailed specifications 12 16 20 25 32 40 50 63 80 100 Single 1.2 (0.067) P.1648 2 position SYJ3000 Double Single Double D4.5 (0.25) 2 position VZ3000 P.1652 Single -X 12.5 (0.7) VZ5000 2 position Double Single Double Individual -X 16 (0.9) 2 position VF3000 P.1658 1643 Series MVGQ Precautions 1 Be sure to read before handling.

Positive pressure) 0.000 to 1.000 MPa 0.100 to 1.000 MPa 1.5 MPa 0.001 0.01 0.01 0.1 Rated pressure range Operating pressure range and regulating pressure range Proof pressure kPa MPa kgf/cm2 Note 1) Setting/Display resolution ZSE ISE bar psi mmHg inHg PSE Z I SE3 Fluid that will not corrode stainless steel 630 and 304 12 to 24 VDC, Ripple (p-p) 10% or less 55 mA or less (With no load)

(A) 2 23 (AR) (A) 2 Refer to Best Pneumatics No. 1 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Regulator Series AR Model Specifications Model AR20 Port size 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 AR40 AR20 AR25 AR30 AR40 Model Proof pressure 1.5 MPa 1.0 MPa 0.05 to 0.85 MPa 1/4, 3/8, 1/2 Max. operating pressure Pressure gauge port size 1/8 1/4 Set pressure range Ambient and 5 to 60C (No freezing

Withstand pressure 600 kPa Detection nozzle 1.5 *3 Consumption flow rate 5 L/min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Current consumption 25 mA or less Switch output 1 output (NPN or PNP) Maximum load current 10 mA Maximum applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short

V: Power supply voltage Power consumption P: 20 [kW] Q = P = 20 [kW] P Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = 24 [kW] Power consumption w Derive the heat generation amount from the power e Derive the heat generation amount from the output. supply output. Output (shaft power etc.)

Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ZSE ISE ON YES OFF P-1 P-2 GPM gal (US) PSE Real-time flow rate GPM = gal (US)/min P Window comparator mode H: Hysteresis Z I SE3 Note) Fixed SI unit (l/min, l, m3 or m3 x 10) will be set for the type without the unit switching function.

RSH20, 32 Graphq Graphw 1.0 RSH20 RSH32 0.9 Bore size 50, 63, 80/ = 0 Bore size 50, 63, 80/ = 0.1 Operating pressure P [MPa] 0.8 1300 1300 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 Load weight m [kg] Load weight m [kg] Load weight m [kg] Load weight m [kg] 0.2 800 800 50 0.1 700 700 600 600 0 500 100 200 300 400 63 Lateral load F [N] 500 500 50 400 400 RS1H50, 63,

Please refer to P.125. Specifications AP3200 Normally closed (N.C.)

0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min 1 to 10 L/min 50 to 500 L/min 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min 0 to 0.5 L/min 0 to 1 L/min 0 to 3 L/min 0.5 to 0.5 L/min 1 to 1 L/min 3 to 3 L/min 5 to 500 L/min 2 to 200 L/min 5 to 50 L/min 150 to 3000 L/min 10 to 1000 L/min 10 to 100 L/min 300 to 6000 L/min 20 to 2000 L/min 20 to 200 L/min 600 to 12000 L/min 24 VDC 10% 12 to

= 0.5 MPa m MGTL63 P = 0.5 MPa 100 MGTM63 100 Load mass m (kg) Load mass m (kg) Larger than 100st Larger than 50st 50 40 50st or smaller 75, 100st 30 20 50 25, 50st 40 10 l 30 5 4 3 m 20 2 10 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 30 40 50 100 200 300 400 Eccentric distance l (mm) Eccentric distance l (mm) 300 300 200 MGTL80 P = 0.5 MPa 200 MGTM80 P = 0.5 MPa 100 Load mass m (kg) Load

P-80 (D) This catalog is printed on recycled paper with concern for the global environment.

OUT OUT 1 1 R1/8, NPT1/8 (With M5 female thread), Rc1/8, G1/8, M5 female thread 4, 6 one-touch fitting Piping OUT OUT 2 2 Features 1 2-Color Display High Precision Digital Pressure Switch How to Order Series ZSE40A(F)/ISE40A Rated pressure range ISE40A 14.5 to 145.0 psi ISE40A 01 X P For positive pressure For vacuum/ compound pressure ZSE40A 01 Y P Made to Order Specifications/Description

(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E.