screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90 106 2 2.3 3.2 6 7
(Top view) r r e Pressure gauge unit 2) Code Unit psig/bar MPa w q w q w q 1) Refer to gauge guide (P.1058) for gauge specifications.
Double clevis: Clevis pins, type C snap ring for axis, and Body mounting bolts.
d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) CKQ D-M9ANote 2) BMA3-040S (A set of a, b, c, e) BMA3-050S (A set of a, b, c, e) BMA3-063S (A set of a, b, c, e) Auto switch Switch bracket (Resin) Transparent (Nylon)Note 1) d e White (PBT) c Switch holder b Auto switch mounting screw a * Band (a) is mounted so that the projected part is on the internal side (contact side
2 x M5 x 0.8 (Vacuum port) 6.5 12 12 11 10 10 1 24 14 S O 20 46 24 30 K 15 (70) 10 24 24 12.5 4 12.5 4 10 30 When open F 17 17 54 4 x M6 x 1 through (Thread for mounting attachment) When open G (mm) J 32 68 88 H 176 276 316 G 138 238 278 F 98 158 178 E 38 80 100 D 87 129 149 B C 58 100 120 A MHL2-20D MHL2-20D1 MHL2-20D2 112211221122136 211 251 54 96 116 MHL2-25D 1122D A B C 12.5 +0.030 4H9
4 x N through 2 x M5 x 0.8 (Port size) I D E M Z A + Stroke B + Stroke L W G M K J 25 to 40 Minimum lead wire bending radius 10 Auto switch H thread effective depth C 4 x N through F Q 2 x M5 x 0.8 (Port size) I D E M Z A + Stroke B + Stroke L W E M K J Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A B A B 20
Operating equipment: MHC2-6D A part a b c d e f = 20 (mm) = 3 (mm) = 4 (mm) = 4 (mm) = 5 (mm) = 6 (mm) b c a e B part f d z f1 x.Calculate the inertial moment of the attachment. Assuming the attachment material is aluminium alloy (relative density=2.7), r1= 16.4 (mm).
7 q e @0 !0 o @2 @3 !5 u t !8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No. Description Rod cover Head cover Cylinder tube Piston Spacer for switch type Description Qty.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Series: NCDA1 (Standard w/ Magnet), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 0400 (4"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Series: NCDA1 (Standard w/ Magnet), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal
Series: NCDA1 (Standard w/ Magnet), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9B--Solid State, Gen.
Series: NCDA1 (Standard w/ Magnet), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 0200 (2"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: FM (Full Male, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: M (1m)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,