Auto switches of D-M9N, D-M9P and D-M9B are used. Auto switches of D-M9NV, D-M9PV and D-M9BV are used. Max. Protrusion of Auto Switch from Edge of Body: L, H Max.
Nil S n Reed switch Auto switch A90 Solid state switch M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision style B Basic style 2 pcs. 1 pc. n pcs.
Auto switch model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Dimensions D-M9 Auto Switch Internal Circuit Mounting screw M2.5 x 4 L Slotted set screw D-M9B, N, P D-M9N Indicator light DC (+) Brown 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black 2.7 2.8 4 22 DC () Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC (+) Brown 22 3.2 D-M9B (
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
General Purpose Type, 2-color Indication Type, 2-color Indication Type with Diagnostic Output, Water Resistant 2-color Indication Type, Hygienic Type, Timer Equipped Type, Magnetic Field Resistant Type, Heat Resistant Type, Wide Range Detection Type, Trimmer Auto Switch Solid State Auto Switch Variations Function Type Electrical entry Auto switch model Page Auto switch mounting style D-M9N
Caution Weight Unit: g Operating Precautions D-M9N(V) D-M9B(V) D-M9P(V) Fix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged.
The MHZ2 series is a standard type parallel air gripper, taking the place of the MHQ*2 series. A linear guide provides high rigidity and high accuracy. MHZ2 can operate under higher pressure even at a larger holding point and overhang. High degree of mounting precision is achieved and mounting repeatability is improved. Standard parallel type air gripper, Bore sizes from 10mm to 40mm, Double
The MHC gripper is ideal for use in applications requiring angular gripping. The opening angle ranges from 30 to -10 degrees. A double piston mechanism provides a large amount of gripping force, while maintaining a compact design. The MHC series has a built in speed adjustment and a recessed groove for auto switches. Angular style, compact, air gripper, Large gripping force provided by the
IC circuit 2-wire Yes None 100 V Relay, PLC 24 V 5 V, 12 V 100 V or less IC circuit Lead wire length symbols: 0.5 m Nil (Example) M9N 1 m M M9NWM 3 m L M9NWL 5 m Z M9NWZ Solid state auto switches marked are produced upon receipt of order. For details of auto switches with pre-wired connector, refer to pages 389 and 390.
D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Auto switch part no.
Mass (g) Auto Switch Internal Circuit D-M9N D-M9P D-M9B Auto switch model 0.5 8 8 7 D-M9N 1 14 14 13 Lead wire length (m) DC (+) Brown 3 41 41 38 5 68 68 63 Main circuit of switch OUT Black Dimensions (mm) DC () Blue D-M9l M2.5 x 4 l Slotted set screw D-M9P DC (+) Brown Indicator light 2.6 Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC () Blue VNA D-M9B VNB 3.2 OUT
CE marking Lead wires Oilproof flexible heavy-duty vinyl cord: 2.7 x 3.2 ellipse, 0.15 mm2, 2 cores (D-M9B(V)), 3 cores (D-M9N(V), D-M9P(V)) Note 1) Refer to page 13 for solid state auto switch common specifications. Note 2) Refer to page 13 for lead wire lengths.
(D-M9 only) Recommended Tool Description Wire stripper Model D-M9N-SWY Stripper for a round cable (2.0) can be used for a 2-wire type cable. 10 Auto Switches Precautions 4 Be sure to read this before handling. Operating Environment Warning Caution 1. Never use in an atmosphere of explosive gases. The structure of auto switches is not intended to prevent explosion.
Mass Unit: g D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Caution 0.5 8 8 7 Precautions 1 14 14 13 Lead wire length (m) Fix the auto switch with the set screw attached to the auto switch body.
Weight (g) D-M9N(V) D-M9P(V) D-M9B(V) Auto switch model Precautions Caution 0.5 8 8 7 1 14 14 13 Lead wire length (m) 3 41 41 38 Fix the auto switch with the existing screw installed on the auto switch body.
Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not
Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Solid state switches marked "" are produced upon receipt of order.
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Tie-rod mounting Band mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (Output) Type Special function Electrical entry 3-wire (NPN) 24 V 5 V, 12 V M9N V V V v v IC circuit 3-wire (PNP) M9P V V V v v 2-wire 12 V M9B V V V v v Terminal conduit 3-wire (NPN) Grommet G39 2-wire 12 V
1122Series MXP/MXPJ6 Air slide table 6, 10, 12, 16 How to Order Clean series 11 Vacuum suction type MXP 11 12 15 M9N MXP 22 12 15 M9N Copper, fluorine and silicon-free + low particle generation Number of auto switches Nil s n 2 pcs. 1 pc. n pcs. 22 Vacuum suction type Bore size Stroke mm Type of auto switch 6 10 12 16 5, 10 10, 20 15, 25 20, 30 Nil Without auto switch Refer to the table
Field wireable connector t Y connector M12 D M9N M8 M8 PCA-1557730 Attached to end of the lead wire of the auto switch.