133 47 61 34 52 64 (Max. 73) AVL4000-*04-*DZM 3/4 & 1 128 161 59 77 74 64 (Max. 73) AVL5000-*06 to 10 3/4 & 1 128 161 59 77 34 74 64 (Max. 73) AVL5000-*06 to 10-*DZM Soft start valve with lock out H Air direction Nil Left to Right F Port thread Body size R Right to Left Nil Rc 20 1/4 N NPT 30 3/8 F G 40 1/2 C E D 50 3/4, 1 Electric entry 1(P) 2(A) Port size Manual lockout Nil 1/4 (AVL2000
Size 26 mm Port size Symbol 03 04 Size 18 mm Size 26 mm Port size 3/8" 1/2" @1 Gasket EVVS1002-9-1H EVVS1001-9-1H Size 18 mm Size 26 mm Note) Part no. for 1 pc. of gasket @2 Tie-rod (2 pcs.)
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
IC Electroless nickel plated Dimensions VBA Caution F A Model ARJ1020F-M5-04 B 10.4 C 4 D E G H J K 21 VE 10.6 (Width across flats: 10) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
Model 6 Size: nominal size X length Number of pieces 8 12 4 6 8 10 12 TM-04 TM-06 TM-08 TM-10 TM-12 2 X 6 2.6 X 8 4 3 X 8 Tube Release Tool Series TG To remove tube in a confined space or from manifolded one-touch fittings.
IC Electroless nickel plated Dimensions VBA Caution A Model ARJ1020F-M5-04 B 10.4 C 4 D E F G H J K 21 VE 10.6 (Width across flats: 10) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock. Failure to observe this procedure could damage the handle or cause the outlet pressure to fluctuate.
(Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes. When the power supply is turned on, the stored accumulated flow value will be displayed and accumulated flow will continue from that point.
(Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes. When the power supply is turned on, the stored accumulated flow value will be displayed and accumulated flow will continue from that point.
(Maintain ON) Especially D-A72 (H) are majorly influenced, use contact protection box without regard to load type and wiring current. x Even when built-in contact protection circuit type (D-A54, A64, A59W) is used contact protection box may be needed, if wire length to load is long (30m or more), or PLC (Programmable Logic Controller) has large inrush current.
LVN Calculation of diaphragm life Example 1) Discharge rate 5 l/min, when operating 8 h/D (for PAX1000) TI/ TIL Discharge rate 5 0.021 238 (cycles/min) = = Cycles per minute PA Discharge per cycle PAX Reference life cycles 1 1 = x x Service life Cycles per minute 8 (Daily operating time) 60 PB 50,000,000 1 1 = x x 238 60 8 437 days = Example 2) Discharge rate 5 l/min, when operating 8 h/
(g) 120 1 1 0 100 90 80 l|AN20002 U1 35 (1.9) .04 (17) NAN3OO-N03 % 60 (3.3) .06 t25) NANtrco+to4 90 (5.0) .08 (35) 60 NAN50(rN0,6 3A 160 (8.8) .36 (165) NAN6OO.NI O 1 27O llsl .46 e25) NAN700+i12 1]4 444 Q4l 1 .87 (4901 Supply pressure: 7l PSI Distance from silencer: NAN200-500-) 31t NAN6O0-7OO+ 6.5fi MN800_900 ,10f1 NANSOO-N,'4 1\h 590 (33) 2.21 (580) NANgOO-N2O 2 960 (53) 3.13 (820) Construction
Note 6) Fixed unit: Instantaneous flow: L/min, Accumulated flow: L Option 1 H Note 2) PNP External input Note 3) With lead wire and M8 connector (3 m) Note 4) Note 2) Made to Order Note 3) Can be selected from accumulated flow external reset and peak/bottom reset. Nil N Without lead wire and M8 connector Note 4) Each option is not assembled with the product, but shipped together.
Grommet (Lead wire length 600 mm) 1 4 1 4 02 3 03 D DIN terminal 3 8 3 8 DO DIN terminal (Without connector) 04 1 2 1 2 1 2 3 4 1 2 3 4 1 04 5 06 Body ported G Grommet (Lead wire length 300 mm) 10 1 1 1 H Grommet (Lead wire length 600 mm) 10 7 12 14 9 20 2 E Grommet terminal 1 4 1 T Conduit terminal 1 4 1 2 D DIN terminal 1 2 G Grommet (Lead wire length 300 mm) Grommet (Lead wire length 600
1) 2) Ejector assembly 1) Standard supply pressure M 0.35MPa H 0.50 MPa 2)1st. ejector Check valve Mounting screw 4pcs.
ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 V A M W 1 1 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 4) 2) 1) 3 300L/min(ANR) M 0.35MPa *2 P 6 600L/min(ANR) H 0.50MPa 3)P V/ *23 (V) (P) 5/ 06 Rc3/4 K1 N.C.+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.
CM AC230V(50Hz) AC 230V50Hz OLR FM MC PRS ILS THR C01 C11 TB IDFC80/90 CN GFCI EDV PE BK WH GR SY BU BR G/Y / AC 230V(50Hz) AC 230V50Hz IDFC60/70/80/90 Series 7-4 IDX-OM-W095 7.5 () IDFC60/70/80/90 Series 7-5 IDX-OM-W095 IDFC60/70/80/90 Series 7-6 IDX-OM-W095 C 8 C 8.1 8.2 1) 2) IDFC60/70/80/90 Series 8-1 IDX-OM-W095 L 9 L L 9.1 0 () 9.2 ADH4000-04 ADH4000-04