HRX-OM-W004-H Operation Manual Communication function Thermo-chiller Air-Cooled Water-Cooled refrigerated type refrigerated type HRR010-A-10HRR012-A-10HRR018-A-10HRR010-A-20HRR012-A-20HRR018-A-20HRR024-A-20HRR030-A-20HRR050-A-20HRR050-A-40HRR010-W-10HRR012-W-10HRR018-W-10HRR010-W-20HRR012-W-20HRR018-W-20HRR024-W-20HRR030-W-20HRR050-W-20HRR050-W-40Keep this manual available whenever necessary
PRESSURE SWITCH WITH T-SPACERIS10T-20-D to IS10T-60-D T 30 IS10 D Symbol Description Body size 20 30 40 50 60 Nil Rc Pipe thread type NPT G + 01 1/8 02 1/4 03 Port size 3/8 04 1/2 06 3/4 + Nil 0.1 to 0.4MPa a Set pressure range 6Note2) 0.1 to 0.6MPa + Semi-standard Nil 0.5 3 b Lead wire length Z 5 + Nil MPa c Pressure unit of the scale plate P MPa/psi dual scale Note 1) A semi-standard
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
IZN10 IZN10 IZN10 IZN10 01 01 01 01 P P P P 06 06 06 06 Z Z Z Z B1 B1 B1 B1 IZN10 AC 01 02 11 Rc1/8 NPN P PNP 06 6 07 6.351/4) 16 6 ( 17 6.351/4() (3m) Z (10m) N IZN10-NT L DIN IZN10A002 IZN10B1 L B2 B3 DIN 01 06 ES 2 01 ES 17mm 2 2 02 3 3 11 Rc1/8 4 4 /IZS30 /IZS30 /IZS30 /IZS30-M2 M2 M2 M2 06 6: 07 6.351/4: 16 6 :( 17 6.35(1/4):() IZN10-CP(3m) IZN10-CPZ(10m) IZN10A003 NPN
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
If even one of the cups do not seal, there can be a loss of pressure to all cups. SMC addresses this problem with series INO Self Sealing Vacuum Cups. By utilizing a small mechanical check valve, it only opens when the cup comes in contact with a part. This will maintain system vacuum pressure if one part is absent.
VQZ (A) 2 (A) 2 VZ 3 (R) 1 (P) 3 (R) 1 (P) VS VFN r e w q r e w q N.O. N.O. (A) 2 (A) 2 3 (R) 1 (P) 3 (R) 1 (P) Component Parts No.
Booster regulator VBA200 VBA400 VBA11 VBAT05(S) Air tank VBAT10(S) VBAT20(S) VBAT38(S) 14-9-7 8 VBAT05 to 38 Related Products: Model (Material: Carbon steel) This is a small capacity air tank to which a booster valve can be connected directly in a compact manner. It does not comply with the Class 2 Pressure Vessel requirement. It can be used alone as a tank.
SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT A One-touch fitting d Part No. A L D VT KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 3.2 4 6 8 10 16 16 18 20.5 22 31.5 32 35 39 43 3.2 6 8 10 12 D VP Color: White VG VP L DIN rail AXT100-DR-l 12.5 (Pitch) 5.25 7.5 VQ Enter suffix number into l from the table below.
Note 2) D-sub connector can use up to 8 stations in on side fitting (Type FD U ). More than 9 stations are for both sides fitting (Type FB). 8 stations (Max. 16 stations) D side ( ) is for the case of a D-sub connector for both sides (Type FB). 3-7-38
A vacuum pad is a consumable part, so it is warranted A vacuum pad is a consumable part, so it is warranted A vacuum pad is a consumable part, so it is warranted A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. for a year after it is delivered. for a year after it is delivered.
O.D.: 6 VP4 U D U side D side 2 to 8 2 to 8 9 to 16 D-sub connector cable assembly Symbol VZS B Both sides Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Stations Symbol VFS 02 2 stations 1 D side VS4 16 stations 16 Max. 16 stations.
F GB GA 2 x P A F' Mounting nut Width across flats B1 A' Rod end nut Width across flats B2 30 D-1 D E J C MM Without rod end thread NN W B (mm) Symbol A A' B B1 B2 C D E F F' GA GB H J MM NN P S W Z Bore size 6 10 16 7 9 14 14 5.5 2 3 16.5 8 6.5 5.5 6.5 17 6 M3 x 0.5 M10 x 1.0 M3 x 0.5 16 3 33 10 12 15 17 7 2.5 4 19 8 6.5 6 7 20 7 M4 x 0.7 M12 x 1.0 M3 x 0.5 19.5 3 39.5 12 14 20 19 8 3 6
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
It is set to these values when delivered. 2.1 Communication Procedure This product receives a request message from the master computer and sends back a corresponding response message. It does not send a message firstly.
VXF(A)2160 Tank 41l 6 x 10 pcs. VXF(A)2160 Tank 41l 6 x 6 pcs. 10 x 12 pcs. 10 x 12 pcs. Without tube (VXF2280) Without tube Without tube (VXF2280) Flow rate Q (Nl) 10 x 12 pcs. 10 x 8 pcs. 10 x 12 pcs. 10 x 8 pcs. VXF(A)2280 Tank 70l 10 x 8 pcs. VXF(A)2280 Tank 70l 10 x 8 pcs. 10 x 10 pcs. 10 x 10 pcs. 100 mm 100 mm 10 x 10 pcs. 10 x 10 pcs. 10 x 8 pcs. 10 x 8 pcs.
It is set to these values when delivered. 2.1 Communication Procedure This product receives a request message from the master computer and sends back a corresponding response message. It does not send a message firstly.
DIN terminal: VP3185-D Conduit terminal: VP3185-T A B A B VQZ VZ Conduit terminal with indicator light (TL) G 1/2 Max. 11 Applicable cable 6 to 12 VS Light Light VFN Rc 1/4 G 1/2 Rc 1/4 ( ): With indicator light (TL) 4-10-7 8 Made to Order Specifications: Series VP3145/3165/3185 Main Valve Double Acting Type: -X80/X81 How to Order 1 D Z A N X 06 5 1 4 VP31 81 80 Type of actuation Body size
For 4B to 6B, use a 1B socket that has been cut in half and welded. 7. When using piping which is non-standard, piping may interfere with the paddle. When this happens, please machine the paddle accordingly. 8. It cannot be used when a water hammer or pulsation pressure is applied to the fluid. Symbol Contact C (COM) A (N.O.) C Common A Normally Open B (N.C.)
2 1/4 2 0.1 to 0.9MPa 2 02 03 04 03 04 06 1/4 3/8 1/2 3/8 1/2 3/4 1 2 3 4 3/8 03 04 06 3 1 30 3/8 0.005 to 0.15MPa 1 4 1/2 4 45 1 3/4 12 8 4.5 2.5 Without sub-plate Nil 02 03 1(P) Symbol Flow type (VEF2) Flow type (VEF3) Pressure type (VEP3) 2 2(A) 1/4 3 3/8 2(A) 2(A) 1(P) 3(R) 1(P) 3(R) 03 04 06 25 3/8 1/2 3/4 1 4 Note) Does not conform to ISO1179-1. 886 Series VEF/VEP Electro-Pneumatic