SMC Corporation of America
Elite Part Number Search
Search Results "AL50-06-11"

Body Size: 50, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: R (Flow Direction: Right to Left), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)

: °C), Bracket: R (w/Bracket), Calibration Certificate: None, Series: Z (Flow Range: 04: 0.5 to 4 L/min , 20: 2 to 16 L/min, 40: 5 to 40 L/min, 11: 10 to 100 L/min)

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: G (Instantaneous Flow: gal/min, Accumulated Flow: gal.

Port 2(B) Working Principle Port 1(A) VNA01, 11 (N.C.) When the pilot solenoid valve i is not energized (or when air is exhausted from the port 12(P1) of the air operated type), the valve element r linked to the piston t is closed by the return spring u.

PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C PVT317-001TBTPVT317-001TBTSPVT317-001TBTZPVT317-001DBTPVT317-001DBTSPVT317-001DBTZPVT317-001DBPVT317-001DBPVT317-001DBNote 1) mark in the product model numbers denotes the rated voltage. Note 2) mark denotes the valve option.

Standard equipment 1/2B 3/8B 1B (3) Accessory 11/2B Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) Based on discharge rate and discharge temperature (70C) of screw type compressors. Note 3) The accessories should be mounted by user.

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Port size IDK Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 R, Rc 1 R, Rc 1 1/4 R, Rc 1 1/2 Symbol 01 02 03 04 06 10 12 14 Connection type Type Male thread (with sealant) Female thread Symbol M F Plug Yes No No Yes Socket Yes Yes No No Availability Built-in check valve Note) A plug with check valve should be used in combination with a socket with check valve.

Silencer Metal Case Type Series 25 How to Order Exhaust in only one direction Prevents scattering of mist and noise. 25 10 002 Port size Thread type Body size 002 003 004 006 010 1/4 3/8 1/2 3/4 1 R NPT Nil N 04 05 06 07 08 10 11 Specifications Max. operating pressure (1) Fluid Compressed air 1.0 MPa 19 dB (A) JIS Symbol Noise reduction Ambient and fluid temperature 5 to 60C (2) Note 1) It

How to Order Internal pilot operated relieving type regulator AR 25 4 BG 02 Semi-standard Nil Flow direction: Right to left None (Standard) Regulator R Body size Port size Accessory 4 6 8 9 1 2 1 Symbol 1 Description Applicable model 02 03 04 06 10 12 14 20 1 4 Nil 2 1 8 3 B With bracket AR4 5 to 6 5 AR 25 AR 35 2 1 2 3 4 Gauge G46-10-02 G46-2-02 G Regulating pressure range 1 G46-P10-02-X30

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Function: 2 (2 Position Double), Body Option: 11 (Non Plug-in Type Sub-plate, Direct Manual Override), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: N (NPT)

Function: 1 (2 Position Single), Body Option: 11 (Non Plug-in Type Sub-plate, Direct Manual Override), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: N (NPT)

Function: 1 (2 Position Single), Body Option: 11 (Non Plug-in Type Sub-plate, Direct Manual Override), Pilot Type: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: T (NPTF)