) 3-M3 X 0.5 thread depth 6 44 MDHR2-15E port position 42 B 45 120o 11 120o A C 36 M3 X 0.5 M3 X 0.5 Finger opening port Finger closing port 10 M3 X 0.5 Finger opening port M3 X 0.5 Finger closing port 25o 25o MHZ2 MHZJ2 6-M3 X 0.5 thread depth 6 (A, B, C common view) MHQ 3-3 depth 6 +0.02 0 34 (A, B, C common view) MHL2 12h9 0 -0.043 Auto switch mounting groove MHR 1.5 .
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
Male elbow: KRL Inch e l b a c i l p p A . D .
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
(For manifold gasket positioning) 36 1/8 (EA, EB port) 1471 SYA3000/5000/7000 Series Dimensions/SYA7000 Series: Base Mounted 3/8, 1/4 (A, B port) 21 22.5 2 position single 11.5 13.5 SYA714002 03 57 77.5 42 10.4 61 M5 x 0.8 (Pilot port) B A PE 38 46 B A Manual override P EB EA 21 69 6.4 2 x 4.3 (For mounting) 87.5 1.8 (Ventilation hole) 26.5 13.5 20.5 20.5 3/8, 1/4 (P , EA, EB port) 33 3/
Using a regulator in the outlet side When mounting a regulator in the outlet side (A port side), use a residual pressure relief regulator (AR25K to 40K) or a check type regulator. With a standard regulator (AR10 to 60), the outlet side pressure may not be released when this valve is exhausted. 5.
36 1/8 (EA, EB port) 1741 Series SYA3000/5000/7000 Dimensions/Series SYA7000: Base Mounted 3/8, 1/4 (A, B port) 21 22.5 2 position single 11.5 13.5 SYA714002 03 57 77.5 42 10.4 61 M5 x 0.8 (Pilot port) B A PE 38 46 B A Manual override P EB EA 21 69 6.4 2 x 4.3 (For mounting) 87.5 26.5 1.8 (Ventilation hole) 13.5 3/8, 1/4 (P , EA, EB port) 20.5 20.5 33 3/8, 1/4 (A, B port) 21 22.5 2 position
) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5 9.5 9 12 B 8 8.5 10.5 11.5 15.5 Hs 24.5 26 29 33 38.5 45.5 Hs Hs 22 24 26.5 30.5 36 43 A 7 6.5 8 10 9.5 12.5 20 25 32 40 50 63 20 25 32 40 50 63 32.5 35.5
Model VHS4510 VHS4510-06 VHS5510 1 (P) 2 (A) 3/4 1 1/4 3/8 1/2 3/4 Port size 1/2 1/2 3/8 3 (R) 77 1 (P) 2 (A) 27 82 125 38 55 Effective area (mm2) Push the handle and then turn. Double action construction prevents erroneous operation. 49 2 (A) 3 (R) 36 42 40 50 53 0.77 0.42 Mass (kg) 0.36 Combination with modular type FRL is possible.
+0.4 +0.2 CW CX CZ L RR CT CZ -0.1 -0.3 CW B + Stroke L 10 15 6.5 12 8 6 RR CL + Stroke 16 18 8 16 10 9 A + Stroke 20 20 10 20 10 10 25 20 18 36 12 10 30 22 18 36 12 10 40 28 22 44 12 14 8 Series MQQ Accessory Dimensions Female-male thread conversion joint Rod end nut d NN Rod MM D C C B H E F A B H Applicable bore size (mm) Applicable bore size (mm) Part no.
A 30 20 20 45 55 4.5 11.5 40 15 4.5 6.5 1.6 20 41.5 ZS-24-A Bracket A View A Bracket D A 30 20 20 45 55 4.2 4.5 40 11.5 15 7.2 7.5 1.6 41.5 35 22 ZS-24-D Bracket D View A Cutting dimensions for panel mounting 43 or more Panel mount 0 +0.5 36 42.4 7.8 25.4 0 +0.5 36 70 or more 47.4 Front protection cover The thickness of the panel is to 3.2mm. 8 For General Fluids High Precision Digital Pressure
U A B B A D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U SMC SMC Approx. U B A B A Approx. U D-A73C D-A80C D-J79C D-A7*C,D-A80C Approx. U Approx. U D-A7*C,D-A80C A B A B Approx.
Use a watchmaker driver whose grip dia. is 5 to 6mm when tightening the auto switch mounting screw.
OUT2 NC Sensor 8 Load 41.8 4 40.3 OUT1 40 4.3 Black Main circuit 7 3 Load Brown 6 2 + SMC FLOW SWITCH Blue 5 1 35.8 36 12 to 24 VDC Series PF2W5 A 40 UNIT RESET PF2W30-A SET Panel fitting dimension 3 x 7.2 (= 21.6) 8-M3 36 +0.5 0 6.4 OUT2 NC Sensor 8 Load 4 OUT1 Black 1 2 3 4 Main circuit 7 3 Load +0.5 0 Brown 19.4 6 2 + Blue 5 1 12 to 24 VDC 5 6 7 8 Series PF2W5 PF2W31-A View A The applicable
The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10). Output (OUT1) Indicator DOWN Button ( Button) Lights up when OUT1 is ON. UP Button ( Button) Use when decreasing a setting value. Use when increasing a setting value. MODE Button ( Button) SET Button ( Button) Use when changing a function. Use when selecting a function.
OUT2 41.8 40.3 NC 8 Load 4 Sensor 40 4.3 OUT1 Black Main circuit Main circuit 7 3 Load Brown 6 2 Blue + SMC FLOW SWITCH 5 1 12 to 24 VDC Series PF2A5 35.8 A 40 UNIT PF2A30-A RESET SET OUT2 NC 8 Load 4 Sensor OUT1 Panel fitting dimensions Black 3 x 7.2 (=21.6) 7 3 Load 8-M3 36 +0.5 0 6.4 Brown 6 2 + Blue 5 1 12 to 24 VDC 1 2 3 4 Series PF2A5 PF2A31-A 36 +0.5 0 19.4 Do not connect the white
Caution When removing a cable with connector, a PCW-04T puller is required. 8
A Groove position of auto switch B 1.8 1.6 Model MHK2-12 MHK2-16 A 10.4 12.8 B Standard switch grooves Dimensions A and B of other models are same as standard switch grooves. Contact P/A for the details on dimensions, specifications, and delivery time. 28