SMC Corporation of America
Elite Part Number Search
Search Results "AL30-F03-36-A"

Do not use a load that generates surge voltage. Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch having a built-in surge absorbing element. 8.

Spacer Y20 Seal for additional station ISA-7-B End plate L ISA-6-A End plate R ISA-6-B ISA-7-A When a 2 port solenoid valve is connected to the right: When 2 air catch sensors are connected or when a 2 port solenoid valve is connected to the left: Joint bracket ISA-3-A Lead wire with connector (Individual wiring type) ISA-8-A ISA-8-B Bracket ISA-4-A DIN rail mounting bracket ISA-9-A Straight

watch maker's screwdriver with a grip diameter of 5 to 6mm.

"Jumping" is a condition in which the cylinder operates without control at a speed that is higher than the control speed.

-M3 X 0.5 (Piping port) 33 36 (Non-locking) Manual override B P R R 7 7 SlA 36 2 35 7 13.5 28.5 15 A 21 R2 P R1 VlA 13 1 (Bleed port) 11 10 4 15 10 10 5-M5 X 0.8 (Piping port) 8.2 14 14 15 Bracket VM/VR VH 2 position double: SYJA3220-M3(-F) 2 position double: SYJA3240-M5 10 9 36 7.1 2-M3 X 0.5 (Pilot port) 10 1.8 4 A B (Mounting holes) 3.2 21.5 1.5 22 7 8.2 2.5 (Mounting holes for manifold

B A B A B A B C D Normally closed (NC = b contact), solid state switch (D-F9G/F9H type) are also available.

Hs 8.5 16 16 A 26 B Auto switch A 29 (36) B Dimensions inside ( ) are for D-H7LF. D-C73C, D-C80C D-H7C Approx. Hs Approx. Hs 8.5 8.5 Auto switch Auto switch 16 16 A 36.7 B A 38.2 B D-B5, D-B6, D-B59W D-A3, D-G3, D-K3 Approx. Hs Auto switch 36 Approx.

Y B G A 90 B 90 B G A D Note 1) 90 G A H X X X D Note 1) D Note 1) B B B F E F F E A H A G G RG RT RS B 296 305 C R310 R445 D 93 129 E 60 87 F 10 15 G 6 7 B 296 309 C R390 R495 D 93 129 E 60 87 F 10 15 G 6 7 B 299 307 C R350 R440 D 93 129 F 10 15 G 6 7 H 610 700 A 600 743 A 680 797 A 643 740 15 32 15 32 15 32 Y Note 2) Y Note 2) Y Note 2) X 558 to 573 685 to 708 X 518 to 533 558 to 581 X

Reed switch Solid state switch A B HS D-F7 D-J79 D-F7W D-J79W D-F7BAL D-F79F D-F7NTL D-A7H D-A80H 32, 40 D-F7, D-J79W D-J79, D-F7BAL D-F7W, D-F79F D-F7NTL Auto switch model D-A7H D-A80H A B Hs A B Hs A B Hs Symbol Standard Stroke Bore size (mm) 32 40 9.5 13.5 32.5 36 6.5 9 6.5 9 32.5 36 9.5 13.5 10.5 13 32.5 36 14.5 18.5 Long Stroke Bore size (mm) 32 40 10 13.5 32.5 36 18 24 10 13.5 18 24

L 5 to 6 Straight bladed watchmaker screwdriver Switch mounting screw (M5 X 4l) When auto switch D-Y59 A is used B Auto switch L Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6mm to tighten the auto switch mounting screw.Use a tightening torque of 0.05 to 0.1Nm. As a rough guide, tighten the screw an additional 90 after feeling a tighten resistance.

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

Note 2) When mounting a cylinder with a stroke over 100mm, use the section A mounting threads.

VCA20-12-1A 41 52 30 40 4.5 6 VCA30-12-1A 48 56 36 44 5.5 7 VCA40-12-1A 50 62 38 50 5.5 7 2 mounting screws (for mounting brackets) are included in bracket part no. 17-2-12 7 Series VCA Direct Operated 2 Port Solenoid Valve For Air Dimensions Grommet: G Conduit: C Q F D Q F 300 280 D VC G1/2 C R C R L VDW IN E E VQ Manual override A B B A 2-P Port size 2-P Port size VX2 VX Manual override

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.

As a rule, it should be turned about 90 beyond the point at which tightening can be felt. A B When auto switch D-Y69A is used Auto Switch Hysteresis Auto switches have hysteresis similar to micro switches. Use the table below as a guide when adjusting auto switch positions, etc. Max.

and Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) SMC D-A90 B 11 12 A 16 17 B 15 16 A 15 16 B 14 15 A 12 13 SMC D-A90 20 25 A Approx.

U B A Approx. U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.

6 A @0 @1 !9 #2 !0 #1 A' For ball bushing #5 @5 #0 @8 !7 @6 !3 #8 !2 @1 !0 @9 For slide bearing y For long stroke For 100 @7 For 80, 100 View A-A' Parts list Parts list No. Description No.

D MS T VMG Seal Tube Can be used for a wide range of pressures from a low vacuum up to a pressure of 1.0 MPa The use of a special profile ensures sealing and reduces resistance when the tube is inserted. Body O-ring Stud With thread seal Effective when piping in a confined space. The body and the threaded portion can rotate. Pipe tape is not necessary. PAT.

Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult P/A regarding other voltages.