View A-A Bore size (mm) Stroke range (mm) AF AE AD AC AB AA A G F E D C B AP H 20 25 32 40 50 75, 100, 125, 150, 200 25 62 15.5 13 11 84 5.6 90 45 24 106 M5 x 0.8 depth 10 9.5 depth 6 22 M6 x 1 depth 10 30 65 16.5 13 15 89 6.8 103 45 26.5 120 11 depth 8 M6 x 1 depth 12 M8 x 1.25 depth 14 27 75, 100 125, 150 200, 250 300 35 70 16.5 13 15 94 6.8 118 50 26.5 135 11 depth 8 M6 x 1 depth 12 M8
Supply pressure (MPa) Suction flow (l /min (ANR)) 13-3-11 11 Series ZR Ejector exhaust Ejector supply P port Vacuum pad connection V port Ejector Unit Nozzle Dia./1.0, 1.3, 1.5, 1.8, 2.0 mm Circuit diagram 2 2 Adapter B Silencer Ejector indication Nozzle dia./1.0, 1.3, 1.5 mm ZR1-W 1 10 13 15 2 Ejector 1 1 1 1 (Mounting hole) 1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San
NO.TQ1050188-OM002 PRODUCT NAME Pressure switch for energy-saving control ejector with N.O. type valve MODEL / Series / Product Number ZK2-ZSV#-A-X188 Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Mounting and Installation 17 Installation 17 Easy
(Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.) Indication resolution Indication LED The LED that turns on when the switch output is ON. Indication unit The unit of pressure used in the display. 11 - NO. ZQ-OM01501 No.
-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1, OUT2: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000 ms Enclosure IP40 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: -5 to 50 oC,
-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1, OUT2: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000 ms Enclosure IP65 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: -5 to 50 oC,
-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000 ms -62No.PS-OMS0007-H Product No.
light LED is ON when switch output is ON (OUT1/OUT2: Orange) Digital filter 5 6 0, 10, 50, 100, 500, 1000, 5000 ms Enclosure IP40 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: 0 to 50 oC, Storage: -10 to 60 oC (No condensation or
-segments, 7-segments for other) Operation light LED is ON when switch output is ON (OUT1/OUT2: Orange) Digital filter 4 0, 10, 50, 100, 500, 1000, 5000 ms Enclosure IP65 Environment Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more between terminals and housing (with 500 VDC megger) Ambient temperature range Operation: -5 to 50 oC, Storage
M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table (1) Examine Mr. Mr = 0.2 x 9.8 (40 + 15.5)/1000 = 0.1 A2 = 15.5 Obtain Mar = 13 from Va = 300 in Graph (3). Find the allowable static moment Ma (Nm). Pitch, Yaw moment: Graph (2) Roll moment: Graph (3) 13 Find the load factor 1 of the static moment.
Bore size System Average speed [mm/s] MB, CA2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 500 mm 40 50 63 80 100 1000 900 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal A 1000 900 800 700 600 500 400 300 200 100 0 B 1000 900 800 700 600 500 400 300 200 100 0 C Bore size System Average speed [mm/s] CS1/CS2 series Pressure 0.5 MPa, Load ratio 50%, Stroke 300 mm 125 140 160
Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1
AW2001 AW3001 AW4001 6) Valve ass'y Brass NBR 1349160 131521 6A 13 16212A e Filter element Bronze 11 294-5B 11 1511-5B 11 104-5B Baffle ABS resin 11295 111522 111622 0 Diaphragm ass'y NBR 131445A 131 52 15A 1316211A Deflector ABS resin 112961 11158 11167 Ci) Bowl ass'y 1'<0'., Polycarbonate C200F C300F C400F 0 Valve spring Stainless steel 13491 58 131525 131625 C!!)
8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46 60 70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25
50005 V output (3)The resolution from 1 to 5 V is 1/1000 based on the calculation. (5 V 1 V) / (5000 1000) = 1/1000 Settable value by PLC (AD value) Output signal range (a to b) Voltage [V] Current [mA] Decimal number 0 to 10 1 to 5 0 to 5 0 to 20 4 to 20 Scale upper limit -32766 to 32767 10 5 5 20 20 Scale lower limit -32767 to 32766 0 1 0 0 4 If the data format is scaled data format,
Ratio of discharge rate against fresh water (%) PAX PB 50 0 1 10 100 1000 Viscosity (mPas) Caution Viscosities up to 1000 mPas can be used.
Port 1 Port 2 B Port 2 PS2410202-20-20 4.67" 3.38" 2.63" 2.88" 1 1/4-11 1/2 1 1/4-11 1/2 118.6 mm 85.9 mm 66.7 mm 73.0 mm NPTF NPTF PS2410202-24-24 4.67" 3.38" 2.63" 2.88" 1 1/2-11 1/2 1 1/2-11 1/2 118.6 mm 85.9 mm 66.7 mm 73.0 mm NPTF NPTF Port 1 PS3210202-32-32 4.88" 3.58" 3.06" 3.35" 2-11 1/2 2-11 1/2 123.9 mm 90.8 mm 77.6 mm 85.1 mm NPTF NPTF Dia Wrench Flats Quick Coupling Division 8145
Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .
Non-rotating accuracy when retracted and when no load is applied should be not more than the values shown in the table. 1000 Bore size [mm] Non-rotating accuracy MGPKM MGPKL 12 0.07 16 0.05 20 0.06 25 32 0.05 0.03 40 50 0.04 100 50 40 32 25 20 10 Load mass [kg] 16 12 1 0.1 0.01 100 1000 500 Max. speed [mm/s] 6 MGPK Series Replacement Parts: MGPKM, MGPKL Common 12 to 32 (101 mm stroke