SMC Corporation of America
Elite Part Number Search
Search Results "PF3A702H-L3-M"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LINEAR STRAIGHT ACTUATOR, ACTUATOR, LSA CYL, LOCATING PIN, SC, 100MM LSA CYL, LOCATING PIN, .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, FD, SY7000 BODY PT 1/4, .21021 lb

SMC has improved product performance and reliability with the redesigned SY series valve. The SY3000 and SY5000 have the same valve width as their predecessors, but the flow has been increased by up to 80%, allowing the valve size to be reduced. A built-in strainer in the pilot valve prevents trouble caused by foreign matter. By using H-NBR seal material for the main valve and seals, Ozone

The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications.Simple connection/disconnection, High retaining force, Miniature size, Accepts many styles of plastic tubing, FITTING, CLEAN ROOM, CONNECTORS, M MINI FITTING, 15, M OTHER SIZE RATING, .01100 lb

Please contact us for the latest version.sales@ocaire.com, FITTING, TEE CLN RM, CONNECTORS, M MINI FITTING, P5, M THREADS ONLY, 0.01358 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Please contact us for the latest version.sales@ocaire.com, FITTING, CLN RM, CONNECTORS, M MINI FITTING, 25, M NO SIZE RATING, .01026 lb

Please contact us for the latest version.sales@ocaire.com, FITTING, CLEAN ROOM, CONNECTORS, M MINI FITTING, C5, M 4MM, .00639 lb

Please contact us for the latest version.sales@ocaire.com, FITTINGS, STAINLESS STEEL, CONNECTORS, M MINI FITTING, CX, M 4MM, .00726 lb

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply:

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 06 [ø6 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)],

Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 12 (ø1.2), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure