An air slide table made by SMC Features · A compactly integrated work table and air cylinder.· An air slide table suitable for precision assembly.· Improved mounting repeatability of workpieces and bodies.· An auto switch attaching groove is provided in consideration of safety.· Also usable for vertical axis mounting.· Dual-rod structure.· Wide range of options.
RBQ has a compact design and an interchangeable damper as an option. The RBQ series shock absorbers are available in five sizes and all withstand an impact speed of 3 m/sec.
RBQ has a compact design and an interchangeable damper as an option. The RBQ series shock absorbers are available in five sizes and all withstand an impact speed of 3 m/sec.
The MBB series air cylinder with an end lock has not been refreshed, and so the existing product is still in production (as of May 2018).
It is recommended that MB□Q series low-friction air cylinders be switched to an MB□□Y.
For the NPN type, when the contact between blue (DC minus) and gray (FUNC) is turned ON, the output that opens the supply valve from OUT2 is output via the main circuit of the vacuum pressure switch, and vacuum suction begins. When the vacuum rises to the specified output, OUT2 is automatically turned OFF. The supply valve closes and the vacuum is held in this condition. However, when the
The dew point indicator can be used to determine the state of dryness of the membrane air dryer outlet air.
When the absorbent is blue or pink: Dew point indicator is blue... Dry state Dew point indicator is pink… Wet state When the absorbent is green or yellow: Dew point indicator is green... Dry state Dew point indicator For the -20°C (-15°C) specification, the atmospheric dew point reaches -20°C (-15°C) in about 10 minutes after air is supplied. When a certain amount of drainage is accumulated, the automatic discharge operation is the same for N.O. (normally open) and N.C. (normally closed) types. The pressure setting of the ISG series open type pressure switch is performed using the set pressure adjustment bolt on the top surface of the main body, and the hysteresis (ON to OFF width) is performed using the hysteresis adjustment bolt on the side surface of the main body. (For the drip-proof type with a hysteresis scale plate, the hysteresis adjustment bolt is located inside the screw This trimmer is used to adjust the offset voltage (ion balance). IZF21/31 series ionizers are marked with “ADJUST” on the front of the product. Yes, this is possible. Supply power (12 to 24 VDC) between the brown and blue wires. Wiring of other switch outputs and analog outputs is not required. Yes, for flange sizes 25, 40, and 50, it is available as a special order. PARALLEL SUPPLY/RETURN TYPE MANIFOLD, DIGITAL FLOW SWITCH, WATER, PF3W, F19, 1140.00000 lb INLINE SUPPLY/RETURN TYPE MANIFOLD, DIGITAL FLOW SWITCH, WATER, PF3W, F19, 1140.00000 lb Thermo-chiller, Rack Mount, air cooled, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb Thermo-chiller, Rack Mount, air cooled, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 40 lb 5KW Rack Mount Chiller, NPT Fittings, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 74 lb 5KW Rack Mount Chiller, NPT, & Feet, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 74 lb 0.95 kW, Air-Cooled, Inverter Pump, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 34 lb It is also available for common exhaust from manifolds., SILENCER, HIGH NOISE REDUCTION, AIRLINE EQUIPMENT, AN SILENCER, 1X, AN OTHER SIZE (MISC./OTHER), .06765 lb, ModelApplicable One-touch fitting sizeEffective area (mm2)Recommended flow (m3/min (ANR))Weight (g)Dimensions (mm) ABANB1-C10?10282.0 or less289425 |