Fig. 4-2 [Ex.-2] 5 Guide shaft Bearing Load base External slider Cylinder tube Detail of A Wrong example Correct example Detail of A Load base Load base External slider Clearance Spacer External slider Detail of B Detail of B By tightening of the bolt, the load base and Insert the spacer to keep flexibility in cylinder cylinder body are in the state similar to direct body and load base even
air at the time of 20 oC (The saturation temperature: 10 oC) [ Air Dryer has been set up on the first side ] ID Series 6-1 Specifications 6 1 IDX-OM-X004 Heatless Air Dryer 6 References 6-2 Externals dimensional drawing Tube Size related to installation Bracket connection Model A B C D E Part No.
ITVH N Bracket dimensions With auto drain Model Port size A M L K J H G F E D C B L 178 211 277 321 B 260 298 366 436 T 9 9 11 11 S 8 16 21 26 R 78 97 98 115 P 50 35 45 46.5 U (Body) V (Adapter) 1 4, 3 8 1 4, 3 8 AMR3000 AMR4000 AMR5000 AMR6000 144 166 188 230 182 215 281 325 21.5 18 16 18.5 37 37 42 42 3.2 3.2 4.5 4.5 32 40 48 56 28 37 37 44 51 61 66 81 101 121 131 161 10 10 45 70 260 302
ZFA200 ZFA100 Nil T Rc B NPTF F G ZFA200 How to Order Manifold (2 to 10 stations) Symbol Indicate both the symbols for air suction filter and bracket part no.
Operating Note 3) 2-position 8-6:5, 8-8:6, 8-10:5 8-6:20, 8-8:15, 8-10:10 frequency cycle/sec. 3-position 8-6:3, 8-8:3, 8-10:2 8-6:10, 8-8:10, 8-10:20 Lubrication Not Required Manual override Non-locking push type Protection structure Dust Proof Coil rated voltage 100VAC, 110VAC, 200VAC, 220VAC, 24VDC Allowable voltage range % -15~ +10% of rated voltage Coil insulation Class B or equivalent
(kPa) 80 80 70 70 ZF 60 60 50 50 ZP 40 40 30 30 ZCU 20 20 10 10 AMJ 0 0 10 20 30 40 50 60 70 80 90 100 110 120 20 60 100 140 180 220 260 300 130 Suction flow rate (/min(ANR)) Suction flow rate (/min(ANR)) Misc.
DRAIN (mm) d A B C D E F Weight (kg) Model FH100-06 FH100-08 FH100-10 FH100-12 FH100-16 FH100-20 FH100-24 3/4 102 90 35 200 290 2.5 1 104 1 1/4 110 100 45 265 380 4.3 1 1/2 144 150 128 52 299 430 6.8 2 2 1/2 175 200 157 70 387 540 17.5 3 520
Nut assembly (9) XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 63 80 Valve size Description Part indication No.
, 3) 20-CDQS Standard 2.2-2 20-CDQS Standard long stroke SCQSl 2.2-10 20-CDQSW Double rod 2.2-30 20-CDQSlS Anti-lateral load Air cylinder Series C(D)M2 20-CM2l Standard 1.4-3 20-CM2lA Standard with air cushion SCM2l 1.4-22 20-CM2W Double rod 1.4-50 20-CM2K Non-rotating rod 1.4-66 20-CM2R Direct mounting Air cylinder Series M(D)B 1.7-6 20-M(D)B Standard 20-M(D)BW Double rod SMB-l 1.7-16 20
Output deviation (%F.S.) 0.5 0.5 Out VE 40 0 0 Return VY G 60 0.5 0.5 AL 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Input signal (%F.S.)
-57 Hz: 0.075 mm Constant Amplitude 57-150 Hz: 9.8 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) Conforms to IEC 68-2-6; 10-57 Hz: 0.15 mm Constant Amplitude 57-150 Hz: 19.6 m/s2 Acceleration Sweep Count for X,Y,Z: 10 times (80 minutes in each direction) 9 PneuAlpha Hardware Specification 2 Table 2.8:Environmental and Electrical Specications Insulation Resistance
Dimensions Option Port size A D OUT IN C B Metal bowl Metal bowl with level gauge Without drain cock B B B Drain cock barb fitting Drain cock thread piping With drain guide E Maintenance space B B B 1/4 Barb fitting Applicable tubing T0604 1/4 Width across flats 17 Option/Dimensions N.O N.C B (With auto drain) Model A B C D N.O N.C E AF800 AF900 150 200 408 488 33 46 140 170 448 528 448 528
The fluid in pump chamber A is forced out to the discharge port, and the fluid is sucked into pump Air supply (AIR SUP) 5 port solenoid valves P2 P1 Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Shaft Suction port (FLUID IN) Diaphragm A Diaphragm B Drive chamber A Drive chamber B chamber B from the suction port. 4.
Name Material Remark 1 Body A PBT 2 Body B Brass Electroless nickel plating 3 Handle POM 4 Needle POM 5 End cover Brass Electroless nickel plating 6 Spring Steel wire 7 U-seal HNBR 8 O-ring NBR 9 Needle O-ring NBR 10 Y seal NBR 11 Seal for fitting NBR 12 Cassette 13 Stator POM 14 Valve O-ring HNBR 15 Shaft O-ring NBR 16 Seal NBR For G thread only. 10 - AS*2Q R thread / NPT thread type G thread
Mist Separator : Series AM Standard features on all models MODEL FLOW PORT A B C WEIGHT ELEMENT D NPT in in in lb (cfm) in Die-cast Aluminum with chromate treatment No screw threads or tie rods are required therefore removal and replacement of element is made quick and easy Differential Pressure indicator Internal autodrain Built-in push-to-connect fitting on drain AM150-N02C-T 10 1/
VE System A System B START VY RUN START G AL Analog voltage input 0 to 10V PLC START Robot support (External input operation) RUN START After both systems A and B have been auto balanced, an operation command is input to the controller to operate the cylinder. At the point at which the auto switch for stopping has been tripped, systems A and B are stopped to assemble parts.
Specification A B Flange Size ANSI ISO# 3 Max. Working Pressure No. of Elements Flow Rate (SCFM) Weight lb Dimensions Element 1) Filter 1) Max.
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16 Mcm of deionized water at class 10 clean room (1 l/min flow rate).