to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: (1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
(Including nut, screw, (spacer)) Applicable bore size (mm) 12 BQ-1 BQ-1 Cylinder series 40 BQ-2 BMU1-025 32 BQ-2 BMU1-025 80 BQ-2 50 BQ-2 BMU1-025 100 BQ-2 25 BQ-1 BMU1-025 140 BQ-2 160 BQ-2 125 BQ-2 BQ-1 20 63 BQ-2 BMU1-025 16 BQ-1 CDQ2 MDU RSDQ MK, MK2 CE1 CXT BQ-1 BQ-2 BQ-1 BQ-2 BQ-2 BQ-2 [Mounting screws set made of stainless steel] The set of stainless steel mounting screws (with nuts
to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4
Definitions and Terminology (Supplementary Explanation) 15 -1No.EX-OMV1026-B 1.
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. -2- . / 1 1.5 *3) *3) 1 1 () -3- IR21000 (1) 0.2% F.S. (IR2000:F.S.=0.2MPa,IR2010:F.S.=0.4MPa,IR2020:F.S.=0.8MPa) ) F.S. (2) (3) (4) 0.010.8MPa(IR2000 0.005MPa) 1.
Metric size Inch size 100 200 205 300 400 M5 standard 3.2 1/8 standard 23 04 06 08 10 12 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 1/4 standard 4 6 8 10 12 3/8 standard 1/2 standard With One-touch fittings Use 1/8" tube.
Sintered metallic element particle diameter 30 0.3 standard 1 mm 1 mm 1 mm Particle diameter 0.2 Particle diameter 0.3 Particle diameter 0.4 756 SP Series Made to Order SP SP Side Port Position Rectangular (Select either or .) A B ZCUK AMJ Rc 1/8 Rc 1/8 AFJ AMV P1 P1 ZH -X185 P1 P2 P3 Base part no.
1 ARM Diaphragm (B) e w r y Exhaust Bleed w ARP Diaphragm (C) SUP(1) OUT(2) SUP(1) OUT(2) OUT(2) SUP(1) Exhaust Valve IR u !0 !0 !2 t r !
When pilot valve B is pushed, the air which was acting upon the switching valve is exhausted, and drive chamber B once again switches to a supply state. A continuous reciprocal motion is generated by this repetition. 1. When air enters drive chamber B, the fluid in pump chamber B is forced out, and at the same time Drive unit fluid is sucked into pump chamber A. 2.
AMX-OMZ0094 PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AMD50-(F,N)06 ~ (F,N)10(B,C,D)(-J,L,R,W,Z)-D AMD60-(F,N)10(B,C,D)(-J,L,R,W,Z)-D Contents Page 1. Safety Instructions 2 to 6 2. Application 7 3. Standard specifications 7 4. How to Order 8 5. Construction / Options / Replacement parts 9 6. Bowl assembly specifications 10 to 11 6-1.
Inch size 1/8" 1/4" 5/32" 1/8" 5/32" 1/4" 5/16" 1/8" 5/32" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 3/8" 1/2" Free flow 0.2 0.3 0.4 0.6 0.6 0.7 1.0 1.3 1.5 1.6 1.7 2.5 4.4 4.8 C values: Sonic conductance Controlled flow 0.2 0.3 0.4 0.7 0.8 0.6 0.9 1.3 2.1 2.4 3.3 4.4 4.9 dm3/(sbar) Free flow 0.3 0.4 0.2 0.3 0.3 0.4 0.4 0.3 0.3 b values: Critical pressure ratio Controlled flow 0.2 0.2 0.3 0.3 0.3
Metric size Inch size 100 200 205 M5 standard 1/8 standard 1/4 standard 3.2 4 6 8 23 04 06 08 01 03 05 07 09 1/8" 5/32" 3/16" 1/4" 5/16" Use 1/8" tube.
IEC 60204-1: Safety of machinery --Electrical equipment of machines. (Part1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.
IEC 60204-1: Safety of machinery --Electrical equipment of machines. (Part1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines.
P 1= 0.7 MPa/P 2=0.5MPa PB 31 31 24 Although A, B+ and B marks are indicated on the terminal 55 Effective area at exhaust side(mm 2) AEA block, VFR4000 can be used as either +COM or COM. 45 S at P 2 = 0.5 MPa BEB solenoid valve.
(Tightening torque of 0.3 to 0.4 Nm) Clamp screw B 2.10-23 3 Port Solenoid Valve VQZ100/200/300 Valve Single Unit Base Mounted Plug Lead Unit How to Order Valve VQZ100 VQZ 1 1 5 5 M 01 Series 1 VQZ100 Body width10mm Port size {2(A)port} Without sub-plate Rc(PT)1/8 01 CP Configuration (A) 2 N.C. 1 1 (P) 3 (R) Manual override B: Locking style (Slotted) : Non-locking push style (Flush) Body
PRESSURE SWITCHIS10M-20-1-D to IS10M-60-1-D Model IS10M-20-1-D A B C D 10.6 83.8 66.3 42 12.6 91.8 70.3 53 14.6 97.8 72.3 58.6 16.6 100.8 73.8 59.3 22 110.8 78.8 90 IS10M-30-1-D IS10M-40-1-D IS10M-50-1-D IS10M-60-1-D -19- 11-3.
Replacement method Standard replacement period Refrigerating compressor 1 B 20,000 hours (6 years) Plate type heat exchanger 1 B 20,000 hours (6 years) Water regulating valve 1 B 20,000 hours (6 years) High pressure switch 1 B 20,000 hours (6 years) Low pressure switch 1 A 20,000 hours (6 years) Magnetic contactor 1 A 20,000 hours (6 years) Programmable controllers 1 A 20,000 hours (6 years
auto switch CP95KD B 32 100 W S Z76 With auto switch Number of auto switches Auto switch Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs.
0 @1 r ye t !4 !7 !3 wu !8 @0 @2 @3 !6 q !5 !9 i *1 *1 C95K32 A A-A A !2 !