SMC Corporation of America
Elite Part Number Search
Search Results "PSE543-M3-C2"

Series PSE digital pressure switches allow pressure to be controlled from a remote location. Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Pressure sensor for general

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

The use of the DM series, multi-connector, enables panel mount connections with other apparatus and can provide the reliability of one-touch installation and removal of multi-tubes (nylon, polyurethane). As a result, separate transportation of panel and machinery equipment and backup unit exchange is made possible. Built-in one-touch fittings, One-touch installation and removal, Reduced

) 3-M3 X 0.5 thread depth 6 44 MDHR2-15E port position 42 B 45 120o 11 120o A C 36 M3 X 0.5 M3 X 0.5 Finger opening port Finger closing port 10 M3 X 0.5 Finger opening port M3 X 0.5 Finger closing port 25o 25o MHZ2 MHZJ2 6-M3 X 0.5 thread depth 6 (A, B, C common view) MHQ 3-3 depth 6 +0.02 0 34 (A, B, C common view) MHL2 12h9 0 -0.043 Auto switch mounting groove MHR 1.5 .

Size: 32, Motor Mounting Position: D (In-line), Lead: C (Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable:

Size: 32, Motor Mounting Position: D (In-line), Lead: C (Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: B (with Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable:

Size: 40, Motor Mounting Position: D (In-line), Lead: C (Size 25: 3mm, Size 32/40: 4mm), Stroke: 250mm, Motor Option: B (with Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange), Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable: None

Size: 32, Motor Mounting Position: D (In-line), Lead: B (Size 25: 6mm, Size 32/40: 8mm), Stroke: 350mm, Motor Option: without Option, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 7 (Screw Mounting), Communication Plug Connector, I/O

Size: 25, Motor Mounting Position: D (In-line), Lead: C (Size 25: 3mm, Size 32/40: 4mm), Stroke: 30mm, Motor Option: B (with Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: Ends Tapped/Body Bottom Tapped, Actuator Cable Type, Length: M3 (3), Controller: C91 (Ether Net/IPâ„¢), Controller Mounting: 8 (DIN Rail), Communication Plug Connector, I/O Cable: None

External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: U (Light & Surge Suppressor, Non-polar), Manual Override: Non-locking Push Type, Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: w/o Sub-plate, Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: Y [DIN Terminal (EN175301-803) w/Connector], Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 01 (1/8), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed), Bracket: None, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: G (Grommet, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3

Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket), Made to Order: X500 [Pilot Exhaust Port w/Piping Thread (M3