SMC Corporation of America
Elite Part Number Search
Search Results "G46E-4-01M-C"

Specific service Service code Service name 4Bh Allocate_Master/Slave_Connection_set 4Ch Release_Group_2_Identifier_Set 4. Assembly Object (Class ID: 04h) 4-1. Class attribute ID Access rule Description Value 4-2. Class common service Service code Service name 4-3.

bytes, COM3) 0.8 ms EX430-SIL1 (in/out 0/4 bytes, COM2) 3.4 ms Process data minimum cycle time EX430-SIL1 (in/out 2/4 bytes, COM3) 1 ms EX430-SIL1 (in/out 2/4 bytes, COM2) 5 ms 0 byte input/4 bytes output 2 bytes input/4 bytes output (2 bytes input: Device Status) (selectable) Process data length Number of outputs 32 outputs Vendor ID 83 hex EX430-SIL1 (in/out 0/4 bytes, COM3) 237 hex EX430

Series Appearance Class Metric size Inch size 1/4" 3/8" None 1/8" 1/2" 3/4" 6 8 10 12 19 3/16" 1/8" 1/4" 3/8" 1/2" 3/4" 4 2 3 Male 4 P.19 Connector LQ2H 5 2 3 Female 4 P. 20 5 2 3 Male 4 P. 21 Elbow LQ2L 5 2 3 Female 4 P. 22 5 2 3 Male 4 P. 23 Run tee LQ2R 5 2 3 Female 4 P. 24 5 2 3 Male 4 P. 25 Branch tee LQ2B 5 2 3 Female 4 P. 26 5 2 3 Union elbow LQ2E 4 P. 27 5 2 3 Union tee LQ2T 4 P.

depth 4.4 Plug for port (hexagon socket head set screw) 4-M5 x 0.8 x 4l Guide rail width 9 4-M4 x 0.7 Depth 10 4-M4 x 0.7 Depth 6 2-M5 x 0.8 9 5.5 17 21.5 52.5 53.5 25 25 27 5.5 26 27 6.5 6.5 16 17 5 NS 10 12.5 25 14 42 + Stroke 56 + Stroke 4-M4 x 0.7 Depth 6 12 10 + Stroke Stroke (mm) LT NS LB J LA 5 58 20 4 10 10 58 20 10 4 15 68 30 20 4 20 68 30 4 20 25 78 40 4 30 30 78 40 30 4

Note 2) Refer to the specifications of display unit for the flow rate value per pulse. 340 Clean Air Module LLB Series Dimensions LLB3-1-PRVSF V2 49.5 HAA HAW Mounting hole for 4 x M4 AT 45 37 35 IDF IDU 1.5 4 20.5 278.5 50 IDF FS A Valve open and locked position Rc 1/4 (NPT 1/4) Rc 1/4 (NPT 1/4) IDFA 90 (Lever operating direction) Max. 91 IDFB A Hand valve Valve closed position 5.5 39 IDH

Center of gravity . 17 4. Product Specifications . 18 4-1. Magnet gripper . 18 4-2. 3-port solenoid valve . 19 4-3. Auto switch . 20 5.Operating method or operation . 21 5-1Precautions for Design . 21 5-2. Installation . 22 5-3. Wiring example to robot controller (common to NPN/PNP) . 28 5-4.YASKAWA Plug & Play Kit . 29 5-4-1. Installing YASKAWA Plug & Play Kit . 29 5-4-2.

Bit 11 Internal communication error 0x1813 Occurs when an internal communication error . 4 Bit 10 Alarm generation Bit 8~9 of Byte 4 and Bit 7~4 of Byte 5 It is set when any of them is ON, otherwise it is 0. Bit 9 Excessive power supply voltage 0x5110 Occurs when the power supply voltage exceeds the specification.

Port size NPT Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32" 1/4" 5/16" 3/8" 1/2" From one-touch fitting to male thread B Bushing Type AKB 01 A 01 S With sealant (standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction

8 @1 r @4 w 12 to 40 @7 !1 !7 q !6 !0 @2 @3 o @4 @6 y e r !8 @1 @5 u w Rod cross section for 12, 16, 20, and 25 Rod cross section for 32 and 40 With end lock 12 to 40 y !7 !6 q !0 o @2 @3 @4 @6 e r !8 @5 @1 i @8 !4 !5 !2 @9 !3 w Parts list No. 1 2 3 4 5 No. Description Rod cover Head cover Cylinder tube Piston Spacer for switch type Description Qty. Note Material Qty.

How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.

47 (56) 4 stations 2 one-touch fitting 53 (62) Barb fitting 75 (85) 8 stations 2 one-touch fitting 84 (94) Note) ( ): values with bracket 2 Compact Direct Operated 3 Port Solenoid Valve Series VV061 Unit Manifold Internal Wiring In case of 4 stations In case of 8 stations Groove (2 locations) Groove (2 locations) 1 3 5 7 9 1 3 5 2 4 6 8 10 2 4 6 Terminal no.

-DR-4 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $11.55 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-40 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $24.21

-DR-4 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $11.55 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-40 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $24.21

-DR-4 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $11.55 + Add to Quote Add To Cart Add to Cart SMC AXT100-DR-40 din rail, VV5Q* MANIFOLD VQ 4/5 PORT*** $24.21

("State" will change to "c.") (4) Press the [Download to device] button to write this change to the IO-Link device. (1) (3) (4) (2) -26No.EX-OMY0032-B 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) When the Diagnosis tab of the ISE20B-L is selected, the following screen appears.

7/16-20 0.75 0.63 5.75 50 (2.00") 0.75 0.50 1/4 0.75 7/16-20 0.75 0.63 5.75 63 (2.50") 0.75 0.50 1/4 0.75 7/16-20 0.75 0.63 5.88 80 (3.25") 1.13 0.75 3/8 1.25 3/4-16 1.25 0.94 7.50 100 (4.00") 1.13 0.75 1/2 1.25 3/4-16 1.25 0.94 7.50 4 Stainless Steel Air Cylinder Series CG5 NFPA Interchangeable Front Flange Mounting Type CG5F (MF1 Mounting Style) 2-EE NPT KK R E A W M 4FB WF TF ZB + STROKE