Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3
Reuse AS-FE Nominal thread size Chamfered dimension D Min.
When used in a balance control circuit, there are instances in which the check valve cannot release, even though the pilot pressure is 50% of the operating pressure. In these cases, the pilot pressure should be the same as the operating pressure. 3. Use in load factor less than 50%. Speed control under normal operations may not function. Series AQ 2.
(mm) Electrical entry P Port size B C D E F H K L M N A Grommet: G Conduit: C Conduit terminat: T Model Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.
Without D-sub connector D-sub connector entry With D-sub connector With robot cable Without D-sub connector D-sub connector entry With D-sub connector With robot cable Nil Robot adapter Applicable shaft diameter 8 10 11 AHC unit 14 15 20 24 25 M3 M5 Tool adapter Port MA310 1 MA320 1 MA210 Electric specifications Without D-sub connector Without D-sub connector D-sub connector entry With D-sub
[mm] 50mm CCW CW 10 20 30 40 50 60 [mm] b) CW )50mm =0() =10 =-10 50mm CCW CW -50 -40 -30 -20 -10 0 [mm] 50mm CCW CW -40 -30 -20 -10 0 10 [mm] 50mm CCW CW -60 -50 -40 -30 -20 -10 [mm] -29- 4/ A 50mm () 5m 5m 10% 15m 20% -30- 5./ 5.1 (LEC ) ,, () EMG() 1000 1 / (Best Pneumatics No UL ,UL1310 Class2 -31- 5.2 5.3. 90100 DC24VSVON a) b) c) d) e) -32- D () 5. 1. 2.() 3.()
A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV
D-F9H F7PW D-F7PW Reed Auto-Switch A80 D-A80 F79 D-F79 J79W D-J79W A72H D-A72H F7P D-F7P F7NWV D-F7NWV A73H D-A73H J79 D-J79 F7BWV D-F7BWV A76H D-A76H J79C D-J79C M9NA D-M9NA A80H D-A80H F7NV D-F7NV M9PA D-M9PA Water Resistant A73C D-A73C F7BV D-F7BV M9BA D-M9BA 2-Color A80C D-A80C F7PV D-F7PV M9NAV D-M9NAV Indication Type A79W D-A79W M9PAV D-M9PAV Solid State M9BAV D-M9BAV Auto Switch F7BA
(SW1) (SW1) (SW2-3, SW2-4) (SW2-3, SW2-4) 0 33 0 49 1 34 1 50 2 35 2 51 3 36 3 52 4 37 4 53 5 38 5 54 6 39 6 55 ON ON 7 40 7 56 8 41 8 57 1 2 3 4 1 2 3 4 9 42 9 58 A 43 A 59 B 44 B 60 C 45 C 61 D 46 D 62 E 47 E 63 F 48 F 64 -14- 5. Parameter list (Driver side) Please configure the appropriate parameters to enable correct driver operation. Refer to [5.
S. or l ess O perat i ng t em perat ure 0 t o 50( N o dew condensat i on) St andards CE m arki ng, U L( CSA) Encl osure I P65 I P65 equi val ent M odel I TV10 0 I TV20 0 I TV30 0 Si ze ( m m m m m m ) 50 50 109 50 50 131 66 66 152 W ei ght ( N o opt i on) 320 420 720 9 Com m uni cat i on speci f i cat i on ( Com m on) I t em Speci f i cat i ons Rem arks Fi el d bus D evi ceN et Rel ease2
Consult with SMC regarding water resistant types with the above model numbers. * Solid state auto switches marked with are produced upon receipt of order. ** Since D-A9and D-A9V cannot be mounted on 50, use of D-Z7 or D-Z80 is recommended. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ D* Since there are other applicable
) NPTF Nil F N Voltage 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz Other Manual override/Classification 1 2 3 4 5 6 7 9 Electrical entry Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Nil A B Grommet Grommet terminal Conduit terminal DIN terminal G E T D Light/Surge voltage suppressor
Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
Bore size Series CJ2 Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Series MB, CA Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load ratio 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQC1000
(Values at the initial period) VT VP VG Solenoid Specifications VP Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 6, 12, 24, 48 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption type) Varistor Diode (Varistor for 12 VDC
Proper tightening torque (Nm) C(D)U10-D 50 (75) 56 (86) 62 (92) 68 (98) 74 (104) 80 (110) 6, 10 16 20, 25 32 1.08 10% 2.45 10% 5.10 10% 8.04 10% M3 M4 M5 M6 C(D)U16-D 95 (128) 106 (143) 117 (154) 128 (165) 139 (176) 150 (187) 172 (209) 194 (231) C(D)U20-D 176 (230) 193 (252) 210 (269) 227 (286) 244 (303) 261 (320) 295 (354) 329 (388) C(D)U25-D 262 (335) 286 (364) 310 (388) 334 (412) 358
A B C D E F G H LAT3-10 10 49 4 60 50 4 10.5 LAT3-20 20 69 6 25 90 80 14 20.5 LAT3-30 30 89 6 25 120 110 24 30.5 13 - LAT3-50 Note 1) Refer to Mounting screw specifications and tightening torques in section 4.3 Mounting (P.24). Note 2) The length of the part of the dowel pin inserted into the positioning hole should be shorter than the specified depth.
H J G G M12 x 1.75 x 40 10 IN OUT IN OUT IN OUT SSA32 G40 X X' M12 x 1.75 x 45 Differential pressure indication switch Differential pressure indicator M16 x 2 x 50 12 Bracket mounting base port size 10 to 24 SSA40 G50 Bracket mounting base port size 03 to 08 M16 x 2 x 60 D D M16 x 2 x 50 J J' 16 SSA50 G60 FH FH X X' X X' M16 x 2 x 60 M20 x 2.5 x 65 M22 x 2.5 x 65 2 x K depth L 20 24 HOW SSA65
As W = 50 < Wmax = 500, the selected model W Wmax can be used.