No.VQ1000V-OMM0002-B 10 - VQ1000/2000 series Specific Product Precautions 3 Be sure to read this before handling How to Calculate Flow Rate Conversion with sonic conductance C: S=5.0XC Q : Air flow rate [dm3/min(ANR)] S : Effective area [mm2] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] t : Temperature [] No.VQ1000V-OMM0002-B 11 - When the valve is failing, use this flow chart
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body Valve Cap Needle Aluminum alloy NBR Rolled steel Brass POM Zinc alloy Chromate plated q w e r Electroless nickel plated Black Black Handle t AS Replacement Parts No. Part no.
Put the end of tool into the release button parallel to the tube. q Kl After inserting, grasp the handle tightly and insert the end of the tubing to the stroke end. w Ml Hl Note) Insert firmly to guard against accidental tube release. Dl After inserting end of tube, relax your grip on the tool. Returning force of spring releases the tube. e MS Tl 2.5-5
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum (Option) Body ported Base mounted Component Parts Description Body Adapter plate End plate Retainer Spool valve Piston Spring Sub-plate Note Platinum silver Platinum silver Platinum silver No. q w e r t y u i Material Aluminium die-casted Aluminium
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum (Option) Body ported Base mounted Component Parts Description Body Adapter plate End plate Retainer Spool valve Piston Spring Sub-plate Note Platinum silver Platinum silver Platinum silver No. q w e r t y u i Material Aluminium die-casted Aluminium
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum (Option) Body ported Base mounted Component Parts Description Body Adapter plate End plate Retainer Spool valve Piston Spring Sub-plate Note Platinum silver Platinum silver Platinum silver No. q w e r t y u i Material Aluminium die-casted Aluminium
Zinc die-casted Aluminium die-casted Material Note q Description Valve guide Body Chromated Chromated Chromated Selection w e Handle r Brass Valve Zinc alloy Caution 1. The valve must be switched to each position instantly and securely. Stopping the handle between the extreme positions may cause malfunction. 2.
Model: 42 (Dual AC), Bar Length: 142 (1420mm), Emmiter Cartridge, Material: V (Energy Saving High-efficiency Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: P (PNP), Power Supply Cable Length: 5 (5m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 3 (-100 to 100 kPa, w/ Unit Selection, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 09 (Inch Size, ø5/16" One-touch Fitting)
Series: 2 (VQZ200), Stations: 8 Stations, Option: None, Thread: 00N (NPT), CE Compliant: Q (CE Marked)
Series: 2 (VQZ200), Stations: 6 Stations, Option: None, Thread: 00N (NPT), CE Compliant: Q (CE Marked)
Series: 2 (VQZ200), Composite Symbol: 3 (Rubber Seal N.C.), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: Y (DIN Terminal), Manual Override: Non-locking Push Style, IP65 Compliant: W (IP65 Compliant), Port Size: N7T (1/4" One-touch Fitting), Option: None, CE Compliant: Q (CE Marked)
Rated Control Flow Range: 25 (0.2 to 25 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: T (
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only)
Rated Control Flow Range: 50 (0.5 to 50 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side))
Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: S (Bracket (mounting position: Stream side))
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: 2U (PFA, 1/4-28UNF), Option: 3 (Bracket + Manual Override), Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Refer to front matters 58 and 59 for Safety Instructions and pages 687 to 691 for Pressure Switch Precautions. q w Locking nut t Wiring Warning e 1. Since the light emitting diode (LED) is used for the light assembly for 24 VDC, there are 2 terminals and polarity. One is + for red load wire and the other is for black load wire. Light will not light up if wired incorrectly. 2.
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual