HECR 12 Data reset Functions can be reset to the default settings (settings when shipped from the factory). t [RUN] lamp Lights up when the product is started, and goes off when it is stopped.
Series 10-VQD1000 [Option] 4 Port Direct Operated Poppet Solenoid Valve How to Order Valve Clean series Valve option Nil Standard (2 W) V Vacuum (2 W) U For large flow (3.2 W) W For large flow, Vacuum (3.2 W) Energy saving type Rated voltage 5 24 VDC 6 12 VDC Body type 2 Body ported (Single unit) 3 Body ported (Manifold) 5 Base mounted 10 V Q D 1 1 5 1 U 5 L M5 Electrical entry
How to Order AL800 AL 23 80 12 0 R AL900 Semi-standard R Flow direction: Right Left Body size Port size Semi-standard Lubricator 1 1S-1 1S-2 2 3 6 8 1000 cm3 tank 1000 cm3 tank with switch (Bottom limit ON) 1000 cm3 tank with switch (Bottom limit OFF) Metal bowl With drain cock Nylon bowl (Including sight dome) Metal bowl with level gauge Symbol 12 14 20 4 1 1 1 2 2 1 80 90 1 2 2 1 Thread
Lube/ALD600-06 to 10, ALD900-12 to 20 Float switch mounting position (Connection port center) AL800 AL900 ALF ALT ALD ALD ALB (Connection port center) LMU F (Bracket mounting dimensions) ALIP AEP HEP Bracket (Option) Bracket dimensions A B C D E Model Port size F 344 416.5 G 32.5 0 H 95 120 J 14 14 K 55.5 48 ALD600-06 to 10 ALD900-12 to 20 , 1 4 3 175 250 175 250 87.5 125 487 639 135 210
Burst pressure Note) Min. bending radius (mm) 24 Burst pressure (MPa) Operating temperature Material 20C to 60C Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.
Note 2) When holding a workpiece close at the end of open/close stroke of fingers, detecting performance of the combinations listed in the above table may be limited, depending on the hysteresis of an auto switch, etc. 12-12-15 12-12-16
Metric size Inch size Type Elbow Universal 2 3 1 8" 5 32" 23 01 3.2 4 6 8 10 12 04 06 08 10 12 03 05 07 09 11 13 3 16" 1 4" 5 16" Control type Meter-out Meter-in 0 1 3 8" 1 2" Use 1/8" tube.
AS120M-M5 M5 x 0.8 9 9 8 10 28.2 24.8 10.3 29.8 33.2 AS120M-U10/32 10-32 UNF AS220M-01 12 R 1/8 Rc 1/8 14.3 14.6 18 31.4 27.4 14.1 32.4 36.4 AS220M-N01 NPT 1/8 12.7 AS220M-02 17 R 1/4 Rc 1/4 18 19.5 27.2 35.9 29.9 18 34.9 39.9 AS220M-N02 NPT 1/4 17.5 Dimensions of R and NPT threads after installation. 15-9-63
Solenoid valve model VO307-1 0.3 to 0.7 MPa Valve unit Small flow Large flow Solenoid valve type Stop valve Skip valve Valve type Nominal size (mm) 63, 100 100, 160 External pilot pressure N.O No mark 100, 200, 110, 220, 240 No mark N.O AC (50/60 Hz) Coil rated voltage (V) 24, 12 Valve opens when solenoid valve conducts electricity.
Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.
(Put packing B w on the surface contacting to the end plate.) 4 stations (12 stations) 5 stations (13 stations) 3. For a style with a D-sub connector, open the cover !4 and insert the pin of lead wire assembly !0 as shown in the right figure.
Fault No.12 Fault Probable cause Recommended error handling Recommended action Valves do not work but valve LEDs are operating Mismatch polarity between solenoid valve and SI unit output Check if the solenoid valve common specification matches the output polarity of the SI unit.
LED in pairing mode (wireless master) -104No.EX-OMV0017 (12) Click the Refresh button to update the information in the setting tab window.
EX600-ZT1 (6) Assembled type connector PCA-1446553: For EtherCAT communication, M12 (4 pin) Plug, D code PCA-1578078: For power supply, 7/8 inch, Plug, Cable O.D. 12 to 14 mm PCA-1578081: For power supply, 7/8 inch, Socket, Cable O.D. 12 to 14 mm (7) Power supply cable PCA-1558810: Cable with 7/8 inch connector, Socket, Straight 2 m PCA-1558823: Cable with 7/8 inch connector, Socket, Straight
Pressure Characteristics 3 5%F.S. (0 to 0.75 MPa, 0.35 MPa standard) Power supply voltage 12 to 24VDC 10% Ripple (p-p) 10% or less Electrical Current consumption 55 mA or less Protection Polarity protection Display accuracy 3%F.S. Analogue output accuracy 3%F.S.
Pressure characteristics 3 5%F.S. (0 to 0.8 MPa, 0.6 MPa standard) Power supply voltage 12 to 24 VDC 10% Ripple (p-p) 10% or less Electrical Current consumption 55 mA or less Protection Polarity protection Display accuracy 3%F.S. Analogue output accuracy 3%F.S.
V300 24 V600 Max.30 V80 mA 1 V 2815 V 1 k 29420 mA 12 V300 24 V600 -40No.PF-OMO0007CN PF2A7--28--X560 PF2A7--68--X560 PF2A7--29--X560 PF2A7--69--X560 (15 V) (420 mA) 12 V 300 24 V 600 1 k 5F.S. 1 s A B 1 V 5 V 4 mA 20 mA 1 NL/min 10 NL/min PF2A710 3.5 CFM10 -2 35.0 CFM10 -2 5 NL/min 50 NL/min PF2A750 18 CFM10 -2 176 CFM10 -2 10 NL/min 100 NL/min PF2A711 3.5 CFM10 -1 35.5 CFM10
No.PF-OMG0008-F PRODUCT NAME Digital Flow Switch (Remote type monitor unit) MODEL / Series / Product Number PF2A3## PF2W3## PF2D3## Table of Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 14 Installation 14 Wiring 16 Outline of setting 18 List of outputs 19 Initialize mode 20 Default settings