Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 80, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 100, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 20, Stroke: L(mm): 150, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None, Body Options: Basic Integrated
Cylinder Inner Diameter: D(φ): 25, Stroke: L(mm): 150, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Without magnet, Support bracket: None, Body Options: Basic Integrated
Cylinder Inner Diameter: D(φ): 16, Stroke: L(mm): 150, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Built-in magnet, Support bracket: None, Body Options: Basic Integrated
Cylinder Inner Diameter: D(φ): 20, Stroke: L(mm): 150, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, Operating Pressure(MPa): 0.05~1.0, Specification: Built-in magnet, Support bracket: None, Body Options: Basic Integrated
Cylinder Inner Diameter: D(φ): 20, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 20, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 25, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: G, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 15, Stroke(mm): 150, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 32, Stroke(mm): 150, Max.
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized