Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Thread Type: R, Port Size: 01 (1/8), Dimension, Across Flat [H]: Body Size 1: 9mm; Body Size 2, 3, 4 None, Applicable Tubing O.D.: 03 (Ø5/32), Seal Method: S (with Sealant)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12J (1 + 2 + J), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: M (Round Type Pressure Gauge w/Color Zone), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 40, Thread: N (NPT), Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: CG (C + G), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: DG (D + G), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Stations: 03 Stations, Port Size: C6 (w/ø6 One-touch Fitting), SI Unit: Q (Device Net), End Plate: 2 [Power Supply w/M12 Connector (Max. supplied Current 2 A)], SI Unit Common: N (-COM), I/O Unit Stations: None, Option 1: D0 (w/o DIN Rail, w/Bracket)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: D (DIN Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 03 (3/8)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC 50/60Hz), Lead Wire: T (Conduit Terminal), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8)