SMC Corporation of America
Elite Part Number Search
Search Results "JJ5SY3-10SKAN-02BS-C6-M"

SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .65408 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM75092%8%1.0 to 50.0 l/min1.0 to 52.5 l/min0 to 52.5 l/min5.00 V20.0 mA

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.56317 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DA, IFW/PFW 1/4INCH PT VERSION, 0.5291 lb

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DA, IFW/PFW 1/4INCH PT VERSION, 0.44092 lb

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .70389 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .63111 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM72592%8%0.5 to 25.0 l/min0.5 to 26.3 l/min0 to 26.3 l/min5.00 V20.0 mA

SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUN SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1X, ZSE40/50/60 OTHER SIZE RATING, .41887 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, 1X, ISE40/50/60 OTHER SZ (OTHER), 1.34746 lb

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: C6 (6mm), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: T (Calibration

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: C6 (ø6), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration

Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon

Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: A (2 NPN Outputs), Unit Specification: Unit Switching Function, Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: