SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-R-P-N02-WK"

8 Fine Lock Cylinder Double Acting, Single Rod Series CLJ2 16 How to Order 16 60 R E L CLJ2 Without auto switch 60 R E H7BW L 16 CDLJ2 With auto switch Number of auto switches Built-in magnet Nil S n 2 pcs. 1 pc. n pcs.

r e Pressure gauge unit 2) Code Unit psig/bar MPa w q w q w q 1) Refer to gauge guide (P.1058) for gauge specifications.

Inch Communication connector P, R port size Symbol Specifications Symbol Port size Nil A T -branch type With 8 one-touch fitting Note) Nil C6 C8 N7 N9 Straight type With 6 one-touch fitting With 8 one-touch fitting With 1/4" one-touch fitting With 5/16" one-touch fitting Metric Refer to Reduced Wiring Fieldbus System (Serial Transmission) in Electric Products (CAT.E150) for details on the

3 Port 3 Position Valve Body Ported VEX3 Series How to Order Air operated Pilot solenoid VEX3 B 12 0 01 1 Air operated VEX3 D B 5 1 12 2 01 Pilot solenoid Operation type Option 1 External pilot solenoid 2 Internal pilot solenoid Nil None Thread type Nil Rc F G N NPT T NPTF Body size Port size B Bracket (VEX312 only) Body size Port size Port 1(P), 2(A), 3(R) 12 01 1/8 02 1/4 Rated voltage

RoHS Desktop Duster Box ZVB Series IZS How to Order IZN A S B ZVB 20 IZF ZVB ZVB q w e r t IZD IZE w Additional air blow B With additional air blow e Photoelectric sensor Nil None Note 1) S With photoelectric sensor Note 2) r AC adapter q Size Note 1) It is necessary to connect an external switch to the external input terminal on the back side of the product.

Manifold base for VQZ200/300 body ported valves, Top mounted piping, Maximum 20 stations available as standard, 1/8 PT or NPT(VQZ200); 1/4 PT or NPT(VQZ300) P and R ports, Optional DIN rail mount, MANIFOLD, VALVE, VV3QZ* MANIFOLD VQZ 3-PORT, UJ, VV3QZ* BUILT IN FITTING ( 0.99208 lb

Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows.

Note 1) Lock position F9BWV F9BW F7BWV J79W F9BA F7BA H R Rear lock Front lock Bore size (mm) Foot Note 2) Flange Double clevis F7NT F79F 32 40 50 63 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-L032 CQ-L040 CQ-L050 CQ-L063 Manual release type F7LF Lead wire length symbols 0.5m . Nil (Example) A80C 3m . L (Example) A80CL 5m . Z (Example) A80CZ None .

Series LQ3 High Purity Fluororesin Fitting Grip seal construction with 3-point seal Easy to assemble & construct Greater swept flow characteristics Excellent heat resistance 150C operating temperature How to Order LQ3 H M 1A Threaded connection Thread Type Symbol Nil N Type R, Rc NPT Fitting Style Symbol H L Style Straight Elbow Piping Type Symbol M Type Male Class Size Combination

Length per roll Indication of tubing model Symbol 20 Roll size 20m roll Caution Color indication Color Black White Red Blue Yellow Green Clear Symbol B W R BU Y G C 1 Applicable for general industry water. Consult P/A if using for other kinds of fluids. Surge pressure must be under the max. operating pressure.

1 0 1 01 Set pressure Gauge port orientation Nil: Standard 0.005 to 0.2MPa 0 OUT IN 1 0.01 to 0.4MPa Knob Gauge port R: R specifications Gauge port JIS symbol Port size Piping port size M5 x 0.8 Rc 1/8 Symbol M5 01 OUT IN Gauge port positions are indicated with the knob on the top side.

Working Principle Diagram Pressure display Output signal Power supply i Control circuit Input signal q Air supply solenoid valve w Exhaust solenoid valve e Built-in regulator Built-in regulator Solenoid valve EXH EXH P u Pressure sensor t Diaphragm r Pilot chamber EXH y Air supply valve SUP OUT 3 5.0 MPa Maximum Supply Pressure Series ITVX2000 High Pressure Electro-Pneumatic Regulator Series

Construction Standard type Double acting type N.C. type N.O. type w e q q e w q e w y t r A B A B With flow rate adjustment u Component Parts No.

Working Principle Diagram VY1 Pressure display VBA VBAT Output signal Power supply i Control circuit AP100 Input signal w Exhaust solenoid valve q Air supply solenoid valve e Built-in regulator Built-in regulator EXH Solenoid valve EXH P u Pressure sensor t Diaphragm r Pilot chamber EXH y Air supply valve SUP OUT 959 ITVH2000 Series ITVH2000 Series Linearity Hysteresis 2.5 1.0 Output deviation

Applicable bore size (mm) Model Port size Weight (g) Effective area (mm2) 32, 40 17 ASN2-M5 M5 x 0.8 5 1.8 50, 63 ASN2-01 1/8 3.6 4 Compact Cylinder with Solenoid Valve/Guide Rod Type Series CVQM Construction e r !1 !5 !9 !7 !2 !8 !4 !6 w !3 q Manual button u 50, 63 !0 t i y o Length of plug connector lead wire Description No.

Description Body Note Baking finish Material q Aluminum alloy w w Aluminum alloy Baking finish Housing e Aluminum alloy Baking finish Drain guard y r Foam rubber Float IN t Stainless steel + Rubber Pilot valve y Resin Lever u Brass Flushing button t i Orifice r o Rubber Diaphragm Replacement Parts 10-1 e No. Description Part no. ADH-D400 Note 10-2 !

Cylinder Port: NPT, Arm Opening Angle: 90°, Arm Position: R (Right Side), Switch Type: T (Turk PNP), R Arm Mtg Position: C (Mounting Position C), R Arm Style: A003 (Straight Plain ref NAAMS ACA102M), L Arm Mtg Position: w/o Arm, L Arm Style: w/o Arm, Painted Arm: P (Paint)

P Part in contact with fluid A part that comes into physical contact with the fluid. Pressure characteristic The amount of variation in the analogue output when the supply pressure is changed. Proof pressure The pressure beyond which the product will be damaged. R Rated flow range The flow range within which the product will meet all published specifications.