D-A7/A8 D-A7H/A80H D-A73C/A80C 10 2 5 1 D-F7 D-J79 D-F7V D-J79C D-A79W D-F7W D-J79W D-F7BAL D-F7WV D-F79F Rail mounting 2 5 1 5 2 15 ( ) 10 1 10 16 2 15 D-F7LF 1 15 Note 1) Cannot be mounted on 6 cylinder. 1.3-14 Standard: Double Acting Double Rod Series CJ2W Mounting Accessories/Refer to p.1.3-12 details.
Wiring diagram LEC6N(NPN) LEC6P(PNP) CN5 24 VDC for I/O signal 24 VDC for I/O signal CN5 A1 A1 COM+ COM+ A2 A2 COM COM A3 A3 IN0 IN0 A4 A4 IN1 IN1 A5 A5 IN2 IN2 A6 A6 IN3 IN3 A7 A7 IN4 IN4 A8 A8 IN5 IN5 A9 A9 SETUP SETUP A10 A10 HOLD HOLD A11 A11 DRIVE DRIVE A12 A12 RESET RESET A13 A13 SVON SVON Load Load B1 B1 OUT0 OUT0 B2 B2 OUT1 OUT1 B3 B3 OUT2 OUT2 B4 B4 OUT3 OUT3 B5 B5 OUT4 OUT4 B6 B6
BBA2: For D-A7/A8/F7/J7 types The stainless steel screws described above are used when the D-F7BAL switch is shipped mounted on to the cylinder.
View D-D D-A73C D-F7V Bore size (mm) C95 D-J79/F7V/F79W/F7WV, D-J79C/F7BA/F7PW, D-J79W D-A79W D-F79F D-A7/A8 D-J79C D-A79W D-A7/A8 Cylinder series D-F7WV D-A80C 63 to 100 Width across flats HT Reinforcing bracket Mounted in case of 301 mm or longer strokes.
Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)
NPN type PNP type Parallel input/output Parallel input/output Signal power supply Signal power supply Parallel IO connector Parallel IO connector 24VDC 24VDC A1 COM A1 COM A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON Load B1 OUT0 Load B1 OUT0 Load
IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON B1 OUT0 B1 OUT0 B2 OUT1 B2 OUT1 B3 OUT2 B3 OUT2 B4 OUT3 B4 OUT3 B5 OUT4 B5 OUT4 B6 OUT5 B6 OUT5 B7 BUSY B7 BUSY B8 AREA B8 AREA B9 SETON B9 SETON B10 INP B10 INP B11 SVRE B11 SVRE B12 ESTOP B12 ESTOP B13 ALARM B13 ALARM CN1 DC24V CN5 DC24V 27 - 7
/NPN LECP6NPNP LECP6P (1) I/O (NPNPNP ) NPN (a) COM+ A1 (b) IN0A3SVONA13 (a) PNP (b) (a) COMA2 (b) IN0A3SVONA13 (2) I/O NPN OUT0B1 ALARMB13 COMA2 PNP COM+ A1 OUT0B1 ALARMB13 23 - 63 / I/O A1 B1 A1 A13 B1 B13 A13 B13 CN5 PLC -A1 COM DC24V /24V A2 COM DC24V /0V A3 INO Bit No.IN05 No.3 A4 IN1 IN5 IN4 IN3 IN2 IN1 IN0 A5 IN2 A6 IN3 OFF OFF OFF OFF ON ON 2 A7 IN4 0 0 0 0 1 1 A8
NPN type PNP type Parallel input/output Parallel input/output Signal power supply Signal power supply Parallel IO connector Parallel IO connector 24VDC 24VDC A1 COM A1 COM A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON Load B1 OUT0 Load B1 OUT0
For BBA2: D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped. When a switch is shipped independently, BBA2 screws are attached.
D-A7, D-A8: Rail mounting type D-M9V: Direct mounting type are shown above. .
D-A7/A8/F7/J7 types cannot be mounted on 12 to 25. Technical data 803 Series CQM The number of surfaces and grooves where an auto switch can be mounted (as direct mounting). The number of the surfaces and grooves where the auto switch can be mounted, by switch type, are shown in the table below. D-A9(V), M9(V), M9W(V), M9A(V)L D-A7, A8, F7, J7 Switch type (Mounting groove no.)
I ffi f l * l l+l {_l l@tt L-I a Noler Thls diagfam is for D A7 or D,A8 type ( ) with D-F7 or D-J7lype.
NPN type PNP type I/O signal power I/O signal power A1 COM CN5 24 VDC A1 COM CN5 24 VDC A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON Load B1 OUT0 Load B1 OUT0 B2 OUT1 Load B2 OUT1 Load Load B3 OUT2 B3 OUT2 Load Load B4 OUT3 Load B4 OUT3 B5 OUT4
BBA2: For D-A7/A8/F7/J7 types D-F7BAL/F7BAVL auto switches are set on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, BBA2 is attached.
A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current Maximum Output current B7 NC
A5 IN3 A5 IN3 A6 DRIVE A6 DRIVE A7 SVON A7 SVON Internal resistance 10 [k] Internal resistance 10[k] A8 NC A8 NC A9 NC A9 NC Main circuit Main circuit Output signal power Output signal power supply supply A10 NC A10 NC 24 VDC 24 VDC DC2(+) B1 DC2(+) B1 DC2(-) B2 DC2(-) B2 BUSY B3 BUSY B3 B4 ALARM B4 ALARM B5 OUT0 B5 OUT0 B6 OUT1 B6 OUT1 Maximum Output current 10 mA Maximum Output current
I ffi f l * l l+l {_l l@tt L-I a Noler Thls diagfam is for D A7 or D,A8 type ( ) with D-F7 or D-J7lype.
Please wire referring to the following diagram * NPN type * PNP type A1 COM CN5 I/O signal power 24VDC A1 COM CN5 I/O signal power 24VDC A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 IN5 A8 IN5 A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON Load B1 OUT0 Load B1 OUT0 B2 OUT1 Load B2 OUT1 Load B3 OUT2 Load
Example of Selection from Minimum Operating Flow 100 Example) Vacuum saving valve used: ZP2V-A8-05 From Table 1, Q2 can be calculated as 5.0 l/min (ANR). 90 31 {l/min (ANR)} 5 {l/min (ANR)} 80 N = 6 (unit) Vacuum pressure (kPa) 70 Q2 = 5.0 l/min (ANR) 60 Table 1.