A T -03M R 3/8 7.7 31.8 78.5 40.5 47.0 1/4 22 24.2 -04M R 1/2 86.6 42.0 50.0 KM KKA6S-03M R 3/8 149.1 44.9 51.4 D -04M R 1/2 10.2 55.3 160.4 46.4 54.4 1/2 30 30.7 KF -06M R 3/4 184.8 46.9 56.4 KKA7S-04M R 1/2 426.1 68.1 76.3 M H -06M R 3/4 13.6 101.5 457.8 69.8 79.3 3/4 36 42.5 H/DL L/LL L -10M R 1 514.0 72.4 82.8 KKA8S-06M R 3/4 873.5 85.4 94.9 -10M R 1 17.6 169.9 931.1 88.0 98.4 1 46 55
fluid*1 Tap water, Deionized (pure) water Set temperature range C CH1: 15 to 25, CH2: CH1 + 0 to 15 Cooling capacity (CH1, 2 total) 50/60 Hz*2,*10 kW 9.5/11.0 Heating capacity (CH1, 2 total) 50/60 Hz*3 kW 2.0/2.5 Temperature stability*4 C CH1: 0.1, CH2: 0.5 Circulating fluid system Rated flow 50/60 Hz*5,*11 L/min CH1: 25/35 (0.5 MPa), CH2: 2/2 (0.5 MPa) Max. flow rate 50/60 Hz*11 L/min 55
5 to 45 Circulating fluid Note 2) Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range Note 1) C 5 to 35 Cooling capacity 50/60 Hz Note 3) kW 9.0/9.5 13.0/14.5 Heating capacity 50/60 Hz Note 4) kW 1.7/2.2 2.5/3.0 Temperature stability Note 5) C 1.0 Circulating fluid system Rated flow 50/60 Hz (Outlet) Note 6) L/min 42/56 Maximum flow rate 50/60 Hz L/min 55
57 59 53 55 57 59 94 95 14.5 AS-FE 14.3 1 8 14.2 36.1 31.1 30.5 25.5 15.5 18.5 21 14.5 15.5 18.5 21 17 18.5 21 22 17 18.5 21 22 21 22 12 KE 15.0 AS-FG 17.2 17 1 4 18.5 39.4 34.4 32.0 26.6 AS-FP 19 AS-FM 1 4 45.9 40.9 38.1 33.1 23.0 19 20.3 AS-D AS-T 19.4 45.0 40.0 37.6 32.6 19 3 8 23.0 ASP 1 2 28.6 24 22.4 54.6 47.1 44.5 37.0 ASN Note 1) Reference dimensions Note 2) Reference dimensions
A B C D E EE F G H J K Applicable model Y200T-D 3.2 67 29 51 24 33 11.5 5.5 15.5 3.5 30 AFF/AM/AMD/AMK20 Y300T-D 4.2 85 42.5 67.5 35 14 7 20 6 41 AFF/AM/AMD/AMK30 Y400T-D 5.2 115 50 85.5 40 55 18 9 26 7 50 AFF/AM/AMD/AMK40 Part no.
[Measurement condition] [Port size] Measurement: Tap water LFE13/8 inch Pressure: 0.2 MPa LFE23/4 inch LFE31 inch Straight pipe length (mm) Model D 5 D LFE1 11 55 LFE2 21 105 LFE3 27 135 -68No.LV50***-OMQ0002-G Stability Fluctuation of the display and the analogue output can be reduced by lengthening the response time setting. 4.0 3.5 3.0 Stability [%F.S.]
PV SV HRS Series 5.19 Communication function 5-55 HRX-OM-M090 Chapter 5 Display and setting of various functions 4. Select serial protocol from the table below with [] key or [] key, and confirm by pressing SEL.
Table 5.23-28 Operation type setting for the contact output signal 2 Set value Explanation Default N.O. type N.C. type HRSH Series 5.23 Communication Function 5-87 HRX-OM-Q026 Chapter 5 Display and Setting of Various Functions Setting/Checking: Selected alarm for contact output signal 2 55. Press the [SEL] key once.
HRL Series 5.4 Description of Screen 5-55 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions Operation mode can be switched from Local mode/Serial mode to DIO mode by inputting a contact signal in contact input 3.
HRL Series 5.4 Description of the Screen 5-55 HRX-OM-X037 Chapter 5 Display and Setting of Various Functions (1) (2) (3) (4) (5) (6) Serial communication setting Table 5.4-25 Setting of serial communication No.
K 46 58 68 M 13 15 19 N 16 15 19 O 18.5 19.5 21.5 F 93.5 107.5 130.5 H 73 88 106 I 76.5 91 110 J 40 46.5 55 K 46 58 68 M 30.9 32.4 41.5 N 16 15 19 Applicable cylinder ML2B25 ML2B32 ML2B40 Applicable cylinder ML2B25 ML2B32 ML2B40 KK 15 16 17.5 LL 28 30.5 37.5 MM 16 21.5 24.5 NN 22 26 37.5 PA Rc 1/8 Rc 1/8 Rc 1/4 PP 56 62.5 78.3 O 69 84 102 KK 15 16 17.5 LL 28 30.5 37.5 MM 16 21.5 24.5 NN
A A1 E1 L1 MM RR1 U1 ND NX NZ L 34 41 42 56 71 79 8.5 16 25 30 30 40 50 55 M8 x 1.25 10.3 11.5 34 41 42 56 71 79 8.5 10.5 14 18 21 21 16 20 22 28 38 44 25 30 30 40 50 55 M8 x 1.25 10.3 12.8 12 16 21 24 11.5 14 14 20 27 31 8 10 10 14 18 22 8 10 18 22 28 32 8 10 10 14 18 22 8 10 18 22 28 32 IY-G02 IY-G03 IY-G04 IY-G05 IY-G08 IY-G10 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10
Refer to page 66 for part numbers. 51 55 Non-standard Motor 10mm/10mm lead Series LTF6 Motor Output Ground Ball Screw 100W Vertical Mount How to Order Motor/switch entry direction Stroke E LTF6 K PH 1 G X10 Left entry Power supply voltage Motor specification Switch specifications Right entry Matsushita Electric Industrial Co., Ltd.
166 187 187 218 218 241 241 277 334 AM150 1 8 1 4 3 8 , , 1 4 3 8 40 40 50 50 55 55 65 85 , AM250 AMl 1 2 3 8 1 2 , AM350 3 4 Related poroducts 1 2 3 4 , AM450 1 2 , 1 1 1, 1 AM550 AM650 3 4 AM450SAM, #4 AM550SAM, #5 AM650SAM, #6 AM150SAM, #1 AM250SAM, #2 AM350SAM, #3 4.6-4 Series AM Dimensions: AM850 Accessory D: With auto drain (N.O.) for AMD850 Options T: With element service indicator
CAT.EX30-1 A Stainless Steel Heat Exchanger Type Air Dryer Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740
threads R Weight g Applicable tubing O.D. mm 2-Applicable tubing P M D KPU04-01 KPU04-02 KPU06-01 KPU06-02 KPU08-01 KPU08-02 KPU10-02 KPU10-03 KPU12-03 KPU12-04 7 8 9 10 15 17 23 25 29 30 41.5 43.5 45.5 46.5 52.5 55.5 59 61.5 63.5 65.5 12 1/8 1/4 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 45.4 49.4 49.6 52.4 56.7 61.3 64.5 67.5 69.7 72.7 4 7.5 18 7.5 10.4 10.4 14 L A M 6 18 19.5 18 12.8 12.8 26 35 45 55
MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S (N) 14 435 45 25 MHZ2-25S (N) 12 4 55 10 MHZ2-10C (N) 31 Single acting type, normally closed 6 115 16 MHZ2-16C (N) 56 10 240 20 MHZ2-20C (N) 83 14 430 25 MHZ2-25C (N) Note 1) Values for pressure of 0.5MPa, gripping point L= 20mm, at center of stroke.
threads R Weight g Applicable tubing O.D. mm 2-Applicable tubing P M D KPU04-01 KPU04-02 KPU06-01 KPU06-02 KPU08-01 KPU08-02 KPU10-02 KPU10-03 KPU12-03 KPU12-04 7 8 9 10 15 17 23 25 29 30 41.5 43.5 45.5 46.5 52.5 55.5 59 61.5 63.5 65.5 12 1/8 1/4 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 45.4 49.4 49.6 52.4 56.7 61.3 64.5 67.5 69.7 72.7 4 7.5 18 7.5 10.4 10.4 14 L A M 6 18 19.5 18 12.8 12.8 26 35 45 55
tubing O.D. mm Weight g 2-Applicable tubing M P D KPU04-01 KPU04-02 KPU06-01 KPU06-02 KPU08-01 KPU08-02 KPU10-02 KPU10-03 KPU12-03 KPU12-04 45.4 49.4 49.6 52.4 56.7 61.3 64.5 67.5 69.7 72.7 1/8 1/4 1/8 1/4 1/8 1/4 1/4 3/8 3/8 1/2 12 41.5 43.5 45.5 46.5 52.5 55.5 59 61.5 63.5 65.5 7 8 9 10 15 17 23 25 29 30 4 7.5 10.4 7.5 18 10.4 14 L A M 6 18 12.8 18 19.5 12.8 26 45 45 70 70 100 26 35 45 55
Short circuit protection IP65 Enclosure Enclosure IP65 [For M8: 20] [For M12: 40] [8 points integrated type, for M8: 55] Weight (g) Weight (g) Note) 100 (Input block + End Block) Note) Since the DIN rail weight is not included, confirm the DIN rail length to be used on page 1-2-25, and add the weight separately which is found in the DIN rail dimension table on page 1-2-97.