R R 1. 2. 2 9 - 3-7 1 ON OFF ON ON 1 2 1 1 1 2 3 3 0.3~0.5mm 4 5 0.3~0.5mm 10 - 2 ON OFF ON ON 1 2 1 1 1 2 3 3 0.3~0.5mm 4 5 0.3~0.5mm 11 - M2.54 5 6 5~6mm 0.05~0.1 Nm90 D-Y59/Y69/Y7P/Y7PV D-M9(V) D-Y7W/Y7WV D-M9W(V) D-M9A(V)L MHL2-10D 0.8 0.3 MHL2-16D 0.5 0.4 MHL2-20D 0.5 0.7 ON MHL2-25D 0.5 0.6 OFF MHL2-32D 0.5 0.6 MHL2-40D 0.5 0.9 1. 2. 12 - 3-8
V] F.S.=514[V] (1%F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1 k 1 M A/D 5 V A/D 5(V)1(M)/(1(k)+1(M))4.995(V)0.005V ) Ripple -8No.PS-OME0003CN-F 1 (DC+) 2 3 (DC-) 4 (IN15 V) A A PSE200/PSE300 (ZS-28-C) M() 37104-3101-000FL Tyco Electronics() 3-1473562-4 () XN2A-1430 () -9No.PS-OME0003CN-F PSE200 PSE300 15V 1 k () -10No.PS-OME0003CN-F (A/D ) () 20 2030 -11No.PS-OME0003CN-F PSE530 PSE531
8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 Note 2) M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order.
1 D. P. Lube (Unit) Series ALD(U)600/900 F.R.L. Standard Specifications Centralized control of multi-point lubrication (1) Model name D.P . Lube D.P . Lube Unit ALDU600 ALDU900 ALD900 ALD600 AV Model Low oil consumption volume 1 4 1 1 1 4 1 1 3 4 1 3 4 1 AU Simplified oil feeding volume setting in which only the pressure differential is adjusted.
P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N
Optional specifications Bracket mount P A B C D E G J M N Q R S T U V AFJ20 1/8, 1/4 40 79.2 9.8 20 25 20 30 27 22 5.4 8.4 40 2.3 28 AFJ30 1/4, 3/8 53 104.1 14 26.7 30 35 26.7 41 35 23 6.5 13 53 2.3 30 AFJ40 1/4, 3/8, 1/2 70 136.1 18 35.4 38.4 40 35.4 50 52 26 8.5 12.5 70 2.3 35 785 AFJ Series Specific Product Precautions 1 Be sure to read this before handling the products.
Mandrel = LD 2d 1 x 100 Here, : Deformation ratio (%) d: Tube diameter (mm) L: Measured length (mm) D: Mandrel diameter (mm) (Twice against the minimum bending radius) Test temperature: 20 5C Relative humidity: 65 5% Air Supply Warning 5.Do not use fluids other than specified. The only fluid that can be used is air. 1. Use clean air.
Series: VQ2000, IN Port Size: 01 (Rc 1/8), OUT Port Size: 01 (Rc 1/8), Option: D [DIN Rail Mounting Style (for Manifold)]
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)
Series: VQ2000, IN Port Size: 01 (Rc 1/8), OUT Port Size: 01 (Rc 1/8), Option: DN (D + N)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: (None), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)
Command bit setting of Controlword Bit 3 Bit 1 Command Transition No. Bit 7 Bit 2 Bit 0 Enable Enable Fault Reset Quick Stop Switch On Operation Voltage Shutdown 0 1 1 0 (2)/(6)/(8) Switch On 0 0 1 1 1 (3) Disable Voltage 0 0 (7)/(9)/(10)/(1 2) Quick Stop 0 0 1 (7)/(10)/(11) Disable Operation 0 0 1 1 1 (5) Enable Operation 0 1 1 1 1 (4)/(16) Fault Reset 0 1 (Note) (15) Note.
Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 1 A single controller monitors up to 4 pressure sensors. 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 1 A single controller monitors 2 4 MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE SET 3 Multi-Channel Controller Series PSE200 Pressure Sensor Series PSE530 Space saving 1 40mm MPa kPa OUT1 76% OUT2 CH 1 2 3 4 PRESSURE SET reduction
C D F J K ARP20(K) ARP30(K) ARP40(K) 28.5 Note 2) 1/8, 1/4 1/8 40 98 27 28.5 M28 x 1 2 1/4, 3/8 1/8 53 117 29 29.5 M38 x 1.5 29.5 2.5 1/4, 3/8, 1/2 1/4 70 148 41 34 M42 x 1.5 34 1 Optional specifications Square embedded type pressure gauge Digital pressure switch Round type pressure gauge Note 3) Bracket mount dimension Panel mount Model Z ARP20(K) ARP30(K) ARP40(K) H J H J H J M N Q R S
Port size Body size Thread size Thread type Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
E C Padlock mounting position C D D SUP SUP. A OUT IN A OUT IN 1 2 3 B B EXH. EXH. H 28 30 36 44 54 G 33 42 44 50 61 F 45 55 58 65 76 E 22 21 26 D 34 46 63 67 78 C 40 53 70 75 90 B 20 29 39 42 53 A 59 78 107 110 134 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 3