VVTA300 05 1 01 Exhaust type Thread type Stations 02 1 Nil F N T 2 stations Individual exhaust 3 Common exhaust Rc G NPT NPTF For manifold Caution 20 20 stations 1. Each valve is fixed on the manifold with two M4 mounting screws. Please tighten the screws properly when valves are reassembled. Screw tightening torque: 1.4 Nm 2.
System error Brown DC(+) Internal data error 12 to 24VDC + Black OUT Load Internal data error Blue DC() 6 Series ZSE30/ISE30 Dimensions 20 0.1 2-M3 x 0.5 Thread depth 4 Lead wire with connector 9.5 25 8 30 3.6 M5 x 0.8 MPa PRESSURE 20 0.1 10 SMC OUT Width across flats 12 SET 1.5 01: R 1/8 T1: NPT 1/8 With bracket 42.5 10 15 4.2 3 22 30 20 25 20 SMC 45 30 1.8 35 35 Panel mount 8 17.8 7.2
Series VXA31/32 Dimensions P port Bracket Pilot port Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com J (Spanner flat) Port size P Port size Rc With bracket K 6 7.5 Symbol Model A B C D E F G H J M 14.5 17 L 29 32 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5
System error Brown DC(+) Internal data error 12 to 24VDC + Black OUT Load Internal data error Blue DC() 6 Series ZSE30/ISE30 Dimensions 20 0.1 2-M3 x 0.5 Thread depth 4 Lead wire with connector 9.5 25 8 30 3.6 M5 x 0.8 MPa PRESSURE 20 0.1 10 SMC OUT Width across flats 12 SET 1.5 01: R 1/8 T1: NPT 1/8 With bracket 42.5 10 15 4.2 3 22 30 20 25 20 SMC 45 30 1.8 35 35 Panel mount 8 17.8 7.2
LP-01 ML1C LC-01 25 32 40 Series Mounting position A B ML1C 177.5 128.5 152.5 123.5 147.5 172.5 D-M5 D-M5W D-M5T Lead wire cap Lead wire clamp Auto switch 14 11 Lead Wire Clamp/Lead Wire Cap (Option) 22 22 B A Lead wire clamp Lead wire cap Series LC-01 LP-01 ML1C (mm) 25 32 40 Mounting position Series A B 124.8 148.8 173.8 ML1C 113.2 137.2 162.2 Minimum Stroke for Auto Switch Mounting Operating
of 01 to 08 when the suffix 0 is removed, are the same as the solenoid valve model codes.
Metric size Inch size Air 1.5 MPa (1.05 MPa Note 1)) 1 MPa (0.7 MPa Note 1)) 0.1 MPa 5 to 60C (No freezing) Applicable cylinder bore size (mm) 2 3.2 4 6 8 10 12 1/2" 3/8" 5/16" 5/32" 1/4" 1/8" AS1002F AS2002F AS2052F AS3002F AS4002F 6, 10, 16, 20 Note) 20, 25, 32 20, 25, 32, 40 40, 50, 63 63, 80, 100 Note 2) Nylon, Soft nylon, Polyurethane Applicable tube material Note 1) In case of AS1002F
Made to Order Lubricant: Vaseline X12 547 Series ASP How to Order ASP 3 30F 01 06 S Made to Order Lubricant: Vaseline X12 Ex.) ASP330F-01-06S-X12 With seal Pilot check valve Body size Applicable tubing O.D.
Screw tightening torque VO307K: 1.35 to 1.45 Nm V11 : 0.14 to 0.17 Nm Parts for manifold 02 03 04 02 03 04 04 06 10 01 02 10 12 01 02 14 20 Description VEX312VEX322VEX332VEX342VEX350VEX370VEX390Bracket (with bolt and washer) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A Foot bracket (with bolt and washer) VEX1-18-2A VEX3-32-2A Silencer for pilot exhaust port (PE) AN120-M5 AN103-01 AN210-02 Note 1
Lead Wire Clamp/Lead Wire Cap (Option) CNS Series Lead wire clamp LC-01 Lead wire cap LP-01 ML1C CLS Lead Wire Clamp/Lead Wire Cap (Option) (mm) CLQ 25 32 40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C LC-01 ML1C MLGP B 113.2 137.2 162.2 25 32 40 Series Mounting position RLQ ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 MLU Operating Range Minimum
Lead Wire Clamp/Lead Wire Cap (Option) CNS Series Lead wire clamp LC-01 Lead wire cap LP-01 ML1C CLS Lead Wire Clamp/Lead Wire Cap (Option) (mm) CLQ 25 32 40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C LC-01 ML1C MLGP B 113.2 137.2 162.2 25 32 40 Series Mounting position RLQ ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 MLU Operating Range Minimum
40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C ML1C LC-01 B 113.2 137.2 162.2 25 32 40 Mounting position Series ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 4.7-11
Model Effective area (With sub-plate) (mm 2) (Nl/min) Response time (2) (sec) Weight (3) (kg) 0.025 or less 0.015 or less 0.045 or less 0.045 or less 0.05 or less Max. operating rate (1) No. of positions Model 1 4 (cycle/sec.) 20 20 10 10 10 VS7-6-FG-S--Q VS7-6-FG-D--Q VS7-6-FHG-D--Q VS7-6-FJG-D--Q VS7-6-FPG-D--Q 2 (Single) 2 (Double) 3 (Closed centre) 3 (Exhaust centre) 3 (Pilot check) 27
OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations Symbol Nil S Material Brass Stainless steel D side U side 1 2 3 4 5 n 02 : 10 2 stations : 10 stations All IN ports are 3/8. Refer to the L dimension table on page 7 regarding the maximum number of stations.
Lead Wire Clamp/Lead Wire Cap (Option) CNS Series Lead wire clamp LC-01 Lead wire cap LP-01 ML1C CLS Lead Wire Clamp/Lead Wire Cap (Option) (mm) CLQ 25 32 40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C LC-01 ML1C MLGP B 113.2 137.2 162.2 25 32 40 Series Mounting position RLQ ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 MLU Operating Range Minimum
Model HTB 1 8 Rc CY1S20 CY1S25 CY1L25 CY1S32 CY1L32 CY1S40 CY1L40 20 20 7.5 20 20 7.5 1 8 Rc 20 23 8.2 24 24 7.5 1 8 Rc 26.5 26.5 8.2 25 25 8 1 4 Rc 30.5 30.5 11 Dimensions except mentioned above are the same as standard type of Series CY1B. Refer to page 8-15-24.
-20 Rubber acting 40 Spring extend) C95 CA1 Non-rotating rod Series CG1K 20 to 63 Rubber CS1 Single rod 1.6-26 Double 40 to 63 Air acting 20 to 63 1.6-30 Double rod Rubber Direct mount Series CG1R Rubber 20 Double to 1.6-35 Single rod acting 63 Air Direct mount/Non-rotating rod Series CG1KR 20 Double to Rubber Single rod 1.6-40 acting 63 Low friction Series CG1Q No cushion 20 Double (20 to
C HRZ008-L1-F 16 14 [HRZ008-L1-F] Cooling capacitykW 12 10 8 6 4 2 0 -20 -10 0 10 20 30 40 Circulating fluid setting temp.deg.