SMC Corporation of America
Elite Part Number Search
Search Results "VHS20W-01-K-D"

Bore size With One-touch fitting U01 U02 U03 U04 1 8 1 4 3 8 1 2 Needle Valve/Flow Characteristics AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 AS2201F-02, AS2211F-02 AS2301F-02, AS2311F-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Number of needle rotations Number of needle rotations AS3201F, AS3211F

M3 Port size With One-touch fitting AS M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 Thread type U10/32 01 02 03 04 ASP R Unified thread (10-32 UNF) Metric thread (M3, M5) Nil ASN N NPT AQ ASV Needle Valve/Flow Characteristics AK AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 ASS Inlet pressure: 0.5

(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.

S K 3 1 0 F 01 06 ASV Speed exhaust controller Option Nil None The effective area is two times larger. (In comparison with control by speed controller) Applicable model: ASV310F, ASV410F, ASV510F C With spatter cover Body size K Hexagonal lock nut 1 2 3 4 5 M3 M5 1/8 1/4 3/8 Note) Option should be indicated in order of C and K. Available only for ASV310F, 410F and 510F.

(N specifications) How to Order AS4200-04 AS3200-03 01 S AS 2 2 0 0 AS2200-02 AS2200-01 Option Body size AS1200-M5 None With seal Nil 1 2 3 4 M3, M5 standard S K N 1 8 1 4 , standard standard standard AS1400-M3 Hexagonal lock nut 8 3 Electroless nickel plated 2 1 If more than one option is required, write option part numbers in the order of S, K, N.

6 Body size If more than one option is required, write option part numbers in the order of K, N. 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size (1) 4 6 8 10 12 04 06 08 10 12 Electroless nickel plated (3) Brass PBT PBT/Stainless steel NBR NBR NBR NBR NBR NBR NBR/Stainless steel Electroless nickel plated Elbow type Control method Meter-out Meter-in 0 With One-touch fitting

U C S O H L 1 Series IRV Dimensions IRV1000 IRV2000 53 55 41 30 50 SMC 35 P K U C SMC S O H L P K U C S O H L 40 34 8 x 6.5 15.4 x 5.4 Approx. 106 Approx. 50.6 18 Approx. 79 Atmosphere Atmosphere 45.5 13 SET VAC SET G SET G 30 SET VAC 43 Pad side Vacuum pump side Pad side Vacuum pump side Approx. 43 35 2-Rc 1/8 Connection port 2-Rc 1/8 Vacuum gauge port 2-Rc 1/4 Connection port Approx. 60

M5, R(PT) 1/8, R(PT) 1/4 Mounting bracket .M5 style only 3.6-1 Digital Pressure Sensor GS40 How to Order GS40 X202 Digital Pressure Sensor PSE ZSE4 ISE4 Port size Optional M5 (Female) R(PT)1/8 R(PT)1/4 5m-long lead wire X202 M5 01 02 ZSE5 ISE5 ZSE6 ISE6 Accessories B None Bracket (M5 style only) ZSE3 ISE3 GS PS Specifications ISA Model GS40-M5 GS40-01 GS40-02 ZSE1 ISE1 Air or inert gas Fluid

Dual Speed Controller with One-touch Fitting Series ASD How to Order ASD 3 30F 01 06 S K Option Body size Nil K None Hexagonal lock nut M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 2 3 4 5 6 With seal Type 3 Universal Applicable tubing O.D.

Body Size: Applicable AC Size: AC20, Handle Operation: Double Action, Thread Type: Rc, Port Size: 1/4, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

Body Size: Applicable AC Size: AC20, Handle Operation: Double Action, Thread Type: G, Port Size: 1/8, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

Body Size: Applicable AC Size: AC20, Handle Operation: Double Action, Thread Type: G, Port Size: 1/4, Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

Body Size: 20 (Applicable AC Size: AC20), Handle Operation: W (Double Action), Thread Type: Rc, Port Size: 02 (1/4), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

Body Size: 20 (Applicable AC Size: AC20), Handle Operation: W (Double Action), Thread Type: F (G), Port Size: 01 (1/8), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

Body Size: 20 (Applicable AC Size: AC20), Handle Operation: W (Double Action), Thread Type: F (G), Port Size: 02 (1/4), Mounting: without Mounting Option, Silencer: without Silencer, Handle Color: Red, Handle Material: Resin, Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa

How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.

Flow Direction Symbols on Body How to Order Meter-out type Meter-in type Indication symbol 2 1 01 06 2 AS 1 F E S K Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Symbol Applicable tubing O.D.

Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 01: R 1/8 T1: NPTF 1/8 IF 2-3.5 Mounting hole 13 Data M5 x 0.8 Connector type 30 SE3C I Z 01 T1 20.5 RESET button DOWN button SET button UP button Lead wire length 600 39 8.5 3.5 (3000) 10 01: R 1/8 T1: NPTF 1/8 2-3.5 Mounting hole 13 M5 x 0.8 16-4-7 8 Series ZSE3/ISE3 Dimensions/Switch Only Grommet type ZSE3

These vortexes are stable under certain conditions, and their frequency is proportional to the flow velocity, resulting in the following formula. f = k x v f: Frequency of vortexes, v: Flow velocity, k: Proportional constant (determined by the vortex generator's dimensions, shape, etc.) Therefore, the flow rate can be measured by detecting this frequency.