a0~60 b25~85%RH c d e 5. f g. h i 6. j k L 2. 7. 8. 1. 9. 2. 10. 11. ()70% ()35% 1. 15% 1. 2. 3 3. () 1. 0.1~1.0MPa 0.3~0.5MPa 0~60 ()35% 2. ) 1. 1. 2. 2. 3. 1. 1. ( 2. 6 ) 3. 2. 50% 4. (6 ) 3. 5. 4. () 0.5 5. 1 2 3. F.G. 1. 4. 1 ISO VG32 1. 2. 1. 2. 3. 1. 2 1. 2. 2. 14.5mT CE2 1.5~2 15,000 18cm 3. 4. IP65 5.
AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
VVT34 Porting specifications 1 0 05 V100 Thread type Port size Nil F N T Rc G NPT NPTF Symbol R Bottom Side P Side Side A SY Symbol Port size 1 0 Side Side 02 1 4 03 3 8 SYJ Instruct by specifying the valves and blanking plate to be mounted on the manifold along with the manifold base model no.
Max. suction flow rate l/min (ANR) Model S M H ZMA05H 0.5 12 18 ZMA07H 0.7 24 23 0.5MPa ZMA10H 1.0 46 36 2 stage diffuser ZMA13H 1.3 95 40 ZMA07M 0.7 16 20 ZMA10M 1.0 0.35MPa 26 32 ZMA13M 1.3 70 36 ZMA13S 1.3 75 38 1 stage diffuser 0.45MPa ZMA15S 1.5 90 45 Series ZMA How to Order ZMA 07 1 H K 5 T14 C Nozzle diameter Switch lead wires (connector type) 0.5mm 0.7mm 1.0mm 1.3mm 1.5mm 05
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve
Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Speed Controller with Uni One-touch Fitting AS Series How to Order 2 2 1 U02 06 AS 1F Hexagon lock nut Round lock nut J Nil Lock nut option Body size AS-F AS-F 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard Made to Order TMH X260 Antistatic type Refer to page 635 for details. ASD None Electroless nickel plated N Nil Option AS Type Elbow Universal 2 3 AS-FE Applicable tubing O.D.
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
S) D H VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN A port LVC 2-G LVA LVH SMC LVD SMC (J) C LVQ LQ E LVN TI/ TIL PA F K B port E PAX PB A B C D E F G H J K S LVN20 LVN30 LVN40 Model 48 60 72 2.4 7.5 8.0 18 24 30 20 26 33 14 25 25 4 5 6 6 9 11 34.5